Top Deal

Waters Micromass Quattro Micro LCMS

ID-number: 44581
Shipping: 4-6 weeks
Status: Provider
€18,900.00
Excl. 19% VAT , excl. Shipping Cost
€22,491.00 incl. Tax
Description:
Waters LCMS. Consisting of:
Micromass Quattro micro mass spectrometer.
Waters 996 PDA detector.
Waters column oven.
Waters 2695 separation module.
Peak Scientific NM32L nitrogen generator.
Edwards E2M28 vacuum pump with EMF20 oil mist filter.
MassLynx software.

Installation

We execute the installation of this laboratory device professionally. We would be pleased to offer you the installation of this laboratory device for €2,210.00, excluding travel expenses.
Read more

Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.

We would be pleased to take over the professional installation of your laboratory devices!
Please contact us.


Benefit from the installation by us in more than one way:

  • Immediate and smooth startup of your laboratory device
  • A professional installation extends the lifetime of your laboratory device
  • Freight charges do not apply*
  • Guarantee extends to 3 months
  • You are entitled to benefit from the Labexchange Repurchase Guarantee.
* products of the product groups laboratory furniture and laminar flow are excluded. In individual cases, other product groups can be excluded.
More Information
Objektnummer B00044581
ID-number 44581
Object name Waters Micromass Quattro Micro LCMS
Manufacture Waters Micromass
Shipping 4-6 weeks
Status Provider

Product group: LC / MS

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:      Waters

model:                  Micromass Quattro Micro

 

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

 

 

Specifications

 

 

Dimensions

 

Height

572mm (23”)

Length

880mm (34.6”)

Width

390mm (15.4”)

 

 

Weights

 

The bench must be able to support the total weight of the system:

 

Instrument

115 kg (253 lb)

 

Data system (computer, monitor, printer)

50 kg (110 lb)

 

Total weight

165 kg (363 lb)

 

 

Operating temperature

The ambient temperature should be in the range 15 - 28°C (59 - 82°F) with a short-term variation (1.5 hr) of no more than 2°C (4°F). The ambient temperature in which the rotary pump is to operate must be in the range 15 - 40°C (59 - 104°F).

The maximum overall heat dissipation into the room is 3.0 kW. This figure does not take into account ancillary equipment such as LC systems. Air conditioning may have to be installed or upgraded to accommodate the additional heat load into the room.

 

 

Operating humidity

The relative humidity should not exceed 70%. It is recommended that the instrument be situated in a draft free position in an air conditioned laboratory free from excessive amounts of dust.

 

 

Shipping and storage temperature

-20 to 60°C (-4 to 140°F)

 

 

Electrical specifications

 

Quattro micro API (including rotary vacuum pump)

 

Voltage & Frequency

230V, 50/60 Hz (+8%, -14%)

Minimum Current

13A

Maximum Current

16A

Power Consumption

2.0 kW

Power Cord Supplied

2.5 m (8 ft.) fitted with country plugs as shown below.

Canada:

The user must supply a fused supply rated at 15A.

UK:

The cable is fused at 13A.

Rest of World:

The user must supply a fused supply rated between 13-16A .

Japan:

A single phase, 3 wire 200V 5% phase/neutral supply rated between 13-16A must be supplied. Additionally, a transformer must be ordered from Waters to boost the input voltage.

Australia & New Zealand:

The equipment has been designed in compliance with the international safety standard IEC1010-1 (EN61010-1). To be fully effective, the building installation must comply with AS 3000: Electrical Installations for Australia / New Zealand.

 

 

 

 

Line frequency

 

50Hz, 47 to 53Hz

60Hz, 57 to 63Hz

 

 

Fuse rating

 

10A, 250V ac

 

 

Electrical safety

 

The Quattro micro complies with the European Directive on Electrical Safety as defined by IEC 1010 and the International standard IEC 1010-1 (EN61010-1).

IEC 1010 Part 1 Ammendment 2. The instrument is categorised as Pollution Category 1 and Installation Category 2.

For Australia and New Zealand: the building installation must comply with AS 3000.

Electrical Safety 195

 