Top Deal

Dionex ICS-3000 LCMS

ID-number: 42305
Shipping: 4-6 weeks
Status: Provider
€24,100.00
Excl. 19% VAT , excl. Shipping Cost
€28,679.00 incl. Tax
Description:
Dionex IC/MS system. Consisting of: Pump ICS3000. Detector ICS3000. Autosampler ICS3000. Thermo Finnigan mass spectrometer LXQ. Dionex PDA ICS Series. Leroy Sommer vacuum pump. Edwards vacuum pump. Software.

Installation

We execute the installation of this laboratory device professionally. We would be pleased to offer you the installation of this laboratory device for €2,840.00, excluding travel expenses.
Read more

Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.

We would be pleased to take over the professional installation of your laboratory devices!
Please contact us.


Benefit from the installation by us in more than one way:

  • Immediate and smooth startup of your laboratory device
  • A professional installation extends the lifetime of your laboratory device
  • Freight charges do not apply*
  • Guarantee extends to 3 months
  • You are entitled to benefit from the Labexchange Repurchase Guarantee.
* products of the product groups laboratory furniture and laminar flow are excluded. In individual cases, other product groups can be excluded.
More Information
Objektnummer B00042305
ID-number 42305
Object name Dionex ICS-3000 LCMS
Manufacture Dionex
Shipping 4-6 weeks
Status Provider

Product group: LC / MS

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:     Dionex

model:                  ICS 3000

  

The following illustrations and descriptions refer to the instrument model and are drawn from brochures.

They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

Specifications:

 
Feature
 
 
Isocratic Pump
 
 
Gradient Pump
 
 
Pump
 
 
Dual-piston (in series), variable speed, 80 μL per revolution
 
 
Dual-piston (in series), variable speed, 80 μL per revolution
 
 
Flow Rate Range
 
 
0.001 to 10.0 mL/min in increments of 0.001 mL/min
 
 
0.001 to 10.0 mL/min in increments of 0.001 mL/min
 
 
Flow Rate Accuracy
 
and Reproducibility
 
 
±0.1% at 1.0 mL/min (typical)
 
 
±0.1% at 1.0 mL/min (typical)
 
 
Operating Pressure
 
 
0.1 to 35 MPa (15 to 5000 psi)
 
 
0.1 to 35 MPa (15 to 5000 psi)
 
 
Pressure Ripple
 
 
1% (typical)
 
 
1% (typical)
 
 
Gradient Proportioning Accuracy and Reproducibility
 
 
Not applicable
 
 
±0.5% at 2.0 mL/min (typical)
 
 
Number of Eluents
 
 
One
 
 
Four
 
 
Gradient Mixer Delay Volume
 
 
Not applicable
 
 
GM-3: <500 μL, 3 to 9 mm ID columns
 
GM-4: <290 μL, 2 mm ID columns
 
 
High Pressure Limit
 
 
0 to 35 MPa (0 to 5000 psi) in increments of 0.1 MPa (14 psi); trips instantaneously
 
 
0 to 35 MPa (0 to 5000 psi) in increments of 0.1 MPa (14 psi); trips instantaneously
 
 
Low Pressure Limit
 
 
0 to 34 MPa (0 to 4900 psi) in increments of 0.1 MPa (14 psi)
 
 
0 to 34 MPa (0 to 4900 psi) in increments of 0.1 MPa (14 psi)
 
 
Vacuum Degassing
 
Module
 
 
Built-in single-channel degas chamber (with degassing membrances) with internal volume of 670 µL and dual-stage diaphragm vacuum pump
 
 
Built-in four-channel degas chamber (with degassing membranes) with internal volume of 670 μL per channel and dual-stage diaphragm vacuum pump
 

 

 
Eluent Generator
 
 

 
 
Operating
 
Temperature
 
 
4 to 40 °C (40 to 104 °F)
 
 
Operating
 
Humidity
 
 
5% to 95% relative humidity, noncondensing
 
 
Operating Pressure
 
 
Minimum: 14 MPa (2000 psi)
 
Maximum: 21 MPa (3000 psi)
 
 
Dimensions
 
 
Height: 40.6 cm (16 in)
 
Width: 22 cm (8.75 in)
 
Depth: 55.9 cm (22 in)
 
Minimum required clearance behind the EG: 5 cm (2 in)
 
 
Weight
 
 
18 kg (40 lb)
 

 

 
Conductivity Detector
 
 

 
 
Electronics
 
 
Microprocessor-controlled digital signal processing
 
 
Detection Types
 
 
Single- or dual-conductivity detection. Dual-detection can be controlled either simultaneously or independently
 
 
Cell Drive
 
 
8 kHz square wave
 
 
Linearity
 
 
1% at 1000 µS
 
 
Resolution
 
 
0.10 nS
 
 
Signal Sampling Rate
 
 
Maximum of 100 Hz
 
 
Electronic Noise, Dry
 
 
S/N ratio = 200,000:1 (Example: 1000 µS:5 nS)
 
 
Electronic Noise, Wet
 
 
At 23 µS, noise <0.2 nS
 
At 1 µS, noise <0.1 nS
 
 
Filter
 
 
Rise times from 0 to 10 s
 
 
Temperature Compensation
 
 
Factory set at 1.7% per °C; programmable from 0.0 to 3.0% per °C
 
 
Cell Body
 
 
PEEK
 
 
Cell Electrodes
 
 
Passivated 316 stainless steel
 
 
Active Volume of Cell
 
 
< 1.0 µL
 
 
Cell Operating Temperature
 
 
5 ºC above the DC detector compartment temperature; maximum of 60 ºC
 
 
Cell Maximum Operating Pressure
 
 
3 MPa (500 psi)
 
 
Signal Gain Ranges
 
 
0 to 180 µS, 0 to 1000 µS, and 0 to 15,000 µS
 
 
Optional Analog Output Full-Scale Ranges
 
 
Three separate ranges from 0 to 15,000 µS
 
 
Electrochemical Detector
 
 

 
 
Electronics
 
 
Microprocessor-controlled digital signal processing
 
 
Detection Types
 
 
Single- or dual-electrochemical detection. Dual-detection can be controlled either simultaneously or independently.
 
 
Noise
 
 
< 1 pA (DC Amperometry)
 
10 pC (Integrated Amperometry)
 
 
Cell Drive Potential Settings
 
 
-2.00 to 2.00 V in 0.001 V increments
 
 
Optional Analog Output Range
 
 
50 pC to 200 μC (Integrated Amperometry)
5 pA to 74 μA (DC Amperometry)
 
 
Cell Working Electrode
 
 
Disposable gold, silver, or platinum
 
Non-disposable platinum, gold, silver, or glassy carbon
 
 
Cell Counter
 
Electrode
 
 
Titanium
 
 
Cell Reference Electrode
 
 
pH-Ag/AgCl combination
 
 
Wetted Materials
 
 
PEEK, titanium, Kel-F, polyetherimide, EPR, glass, high density
 
polyethylene (HDPE), ULTEM, Teflon working electrode
 
materials
 
 
Cell Volume at Working Electrode
 
 
< 0.5 µL
 
 
Cell Maximum Operating Pressure
 
 
0.7 MPa (100 psi)
 

 

 
Thermal Compartment
 
 

 
 
Temperature Control Range
 
 
5 to 85 °C in 0.1 °C increments (41 to 185 °F in 0.18 °F increments); thermo-electric control
 
 
Temperature Accuracy
 
 
±0.5 °C (0.9 °F)
 
 
Temperature Stability
 
 
±0.1 °C (0.18 °F)
 
 
Temperature Precision
 
 
±0.1 °C (0.18 °F)
 
 
Column Capacity
 
 
Up to 3 columns; maximum length of 30 cm (11.8 in)
 
 
Heat-up Time
 
 
< 20 min from 20 to 50 °C (68 to 122 °F)
 
 
Cooldown Time
 
 
< 20 min from 50 to 20 °C (122 to 68 °F)
 
 
Control
 
 
Provided by Chromeleon or Chromeleon Xpress software; the TC and the host computer are connected through USB (Universal Serial Bus)
 
 
I/O Interfaces
 
 
2 digital inputs, 2 programmable relay outputs
 
 
Injection Valve
 
 
Electrically-activated Rheodyne TitanHP valve: 2-position, 6-port
 
or 2-position, 10-port (up to two valves can be installed)
 
 
Safety Features
 
 
Humidity sensor and gas sensor
Temperature control and temperature sensors