TOC

Shimadzu TOC 5050

Special Price €3,250.50
-25%
Discount
until May 31, 2024
Regular Price €4,334.00
Excl. 19% VAT , excl. Shipping Cost
€3,868.10 incl. Vat
ID-number: 32055
Status: Stock unit?The device is in our stock, however, has to be inspected by our technician, in order to be able to guarantee complete function.
Shipping: 10-14 working daysiFor incoming orders until 12:00 (German local time). If customs handling is required, shipment will be delayed.
Description:
Shimadzu TOC analyzer TOC 5050.
With printer OKI Microline 390 elite.
Slide control panel with number pad.
230 V. 50/60 Hz. 1200 W.
Add to Offer List
More Information
Objektnummer B00032055
ID-number 32055
Object name Shimadzu TOC 5050
Status Lagergerät
Manufacture SHIMADZU
Shipping 10-14 working days

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Firma:              Shimadzu

Modell:            TOC 5050

Kommentar:   Dokumente engl.

 

 


Measurement of TC (total carbon)

Pure air carrier gas is flow-regulated to 150mL/min. and allowed to flow through the TC combustion tube which is packed wich catalyst and kept at 680°C. When the sample entern the TC combustion tube, the TC (total carbon) in the sample is oxidized into carbon dioxide. The carrier gas contain­ing the combustion products from the TC combustion tube flows through the IC reaction vessel, dehumidifier, halogen scrubber, and finally reaches the sarnple cell of the nondisper­sive infrared (NDIR) detector, which measures the carbon diox‑

ide content. The Output signal (analog) c :ff , the NDIR detector is

displayed as peaks. The peak areas are measured and proces­sed by the data processing unit.

Since the peak areas are proportional to the total carbon concentrations, the total carbon in a sample can be easily determined from the calibration curve prepared using Standard solutions of known carbon content.

Total carbon is the sum of the TOC (total organic carbon) and the IC (inorganic carbon)

 

Measurement of IC (inorganic carbon)

The sample is injected into the IC reaction vessel which has carrier gas bubbling through the IC reaction solution. Only the inorganic carbon in the sample is converted into carbon doxide, which is then detected by the NDIR detector.

The concentration of inorganic carbon is the sum of carbon­ate and hydrogen carbonate.

 

Measurement of TOC (total organic carbon)

The TOC concentration is obtained by subtracting the IC concentration from the TC concentration.

 

Measurement of NPOC (non-purgeable organic carbon)

An acidified sample is sparged with.high purity air to remove the IC; then the TOC content is measured directly. The result is generally called TOC, out fiere it is specifically caIed NPOC (non-purgeable organic carbon) to distinguish it from the TOC value obtained from the differente between TC and IC. The Spargrog process will remove both IC and those organic carbon cornpounds that are volatile at ambient temperatures.

 

 


Specifications

Analyte

TC, IC, TOC (TC-IC), NPOC (non-purgeable organic carbon)

Method

Combustion/non-dispersive infrared gas analysis method 

Combustion temperature

680° C 

Measuring range

50ppb to 4000ppm (to 5000ppm for IC)

Average analysis time

2 to 3 minutes for both TC and IC (4.5 minutes for TC and 3.5 min. for IC at the longest) 

Repeatability

Standard deviation is less than 1% of full scale for the range less than 2000ppm (less than 2500ppm for IC), and less than 2% for full scale for the range from 2000ppm to 4000ppm (from 2500ppm to 5000ppm for IC).

Sample introduction

Automatic injection

Sample injection volume

4 to 250 µ L

Pretreatment for IC

Automatic sparging function 

Carrier gas

Cylinder of high-purity air, about 600kgf/cm 2 (7kgf/cm 2 max.) in supply pressure; 150 mL/min. in flow rate (300mL/min. including sparging) 

Data processing

.

.

Detector signal 

Linearization, baseline correction, peak detection, and area calculation 

.

Data 

Calculation of calibration curve concentration using unlimited number of points (one to four points for stand-alone mode); automatic selection of best calibration curve; store an unlimited number of calibration curves; automatic exclusion of anomalous value(s) and automatic re-analysis/re-calculation; calculation of standard deviation and coefficient of variation, automatic re-analysis with different measurement range and/or different sample volume when response goes off scale. 

.

Instrument control 

Aspiration, measurement, and injection of sample; TC furnace temperature; ON/OFF of carrier gas and sparge gas. 

.

Other features 

Automatic selection of the optimum set of operation conditions; maintenance/self-diagnostics, warning of abnormality; timer for restarting from the running mode. 

Display

White liquid crystal display with back-light, 640x400 dots, 88 characters x 22 lines.

Printer

Thermal, 240-dot graphic printer, 40 characters/line, 110 mm in chart width.

Ambient temperature requirements

5° to 35° C 

Power requirements

100, 110, 115, 120, 127, 220, 230, or 240V as ordered, ±10%, 50/60Hz, about 300 VA power consumption . (500VA max.) 

Approx. dimensions and weight

480 W X 525 D X 480 H mm (excluding projections), 46 kg 

Optional equipment: SSM-5000A solid sample module

 

 

The system is complete with the solid sample modale SSM-5000A.

·    switch between aqueous and solid samples without further instrument conversions

·    large sample size of up to 1 g

·    separate TC determination (total carbon) and IC (inorganic carbon) enable the exact determination of the TOC contents

·    high sensitivity enables its use in cleaning validation using the glass fibre swab method without the need for extraction

 

Product group: TOC

Back to Top