Agilent 240FS

ID-number: 46525
Shipping: 10-14 working days
Status: Provider
€18,600.00
Excl. 19% VAT , excl. Shipping Cost
€22,134.00 incl. Tax
Description:
Agilent AAS 240FS. With SIPS 20 pump module. Hollow cathode lamps: copper/zinc, sodium/potassium, calcium/magnesium. Software: SpectrAA 5.2.0.4. 230 V. 50/60 Hz: 230 W.

Installation

We execute the installation of this laboratory device professionally. We would be pleased to offer you the installation of this laboratory device for €1,120.00, excluding travel expenses.
Read more

Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.

We would be pleased to take over the professional installation of your laboratory devices!
Please contact us.


Benefit from the installation by us in more than one way:

  • Immediate and smooth startup of your laboratory device
  • A professional installation extends the lifetime of your laboratory device
  • Freight charges do not apply*
  • Guarantee extends to 3 months
  • You are entitled to benefit from the Labexchange Repurchase Guarantee.
* products of the product groups laboratory furniture and laminar flow are excluded. In individual cases, other product groups can be excluded.
More Information
Objektnummer B00046525
ID-number 46525
Object name Agilent 240FS
Manufacture Varian
Shipping 10-14 working days
Status Provider

Product group: AAS

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Varian

model :                   AAS 240 FS

annotation :           Dokumente engl .

 

 

 

 

 

 

 

AA240FS

 

Features

  • Fast Sequential capability
  • Full automation
  • PC control
  • Deuterium background operation
  • True double beam optics

 

 

 

Fully automated PC-controlled true double-beam Atomic Absorption spectrometer with Fast Sequential operation for fast multi-element flame AA determinations. Features 4 lamp positions and automatic lamp selection. Supplied with SpectrAA Base and PRO software versions.

 

 

 

Flame AA Hardware

 

Features

 

Optics

Narrow beam optics match flame and furnace profiles. Fully sealed optics feature quartz- overcoated mirrors for enhanced protection.

The AA240 FS feature a Rotating Beam Combiner, which alternately passes the sample or reference beam into the monochromator for maximum light transmission.

 

Wavelength range

185-900 nm

 

Optical bench

Optics mounted on a reinforced flat plate with a fitted deep-drawn cover for protection from dust and vapor.

 

Monochromator

Automated self-calibrating Czerny-Turner monochromator with microstepping driver for enhanced resolution. PC-controlled wavelength selection and peaking.

 

Focal length

250 mm

 

Wavelength repeatability

±0.04 nm

 

Wavelength slew rate

2000 nm/min.

 

Grating

Holographic diffraction grating with 1200 lines/mm blazed at 240 nm.

Dispersion 3.1-2.3 nm/mm

 

Detector

Selected wide range photomultiplier tube for maximum signal to noise performance

Type R955

 

Slits

Automated slit selection.

Settings: 0.2, 0.5 and 1.0 nm plus reduced height 0.5 nm slit for graphite furnace operation

 

Lamp support

4 lamps mounted in fixed positions

Fast lamp selection using mirror

Manual or automatic operation

( automated lamp selection standard on AA240 FS).

 

All lamps operated simultaneously in Fast Sequential mode

 

Accommodates single or multi-element, coded or uncoded lamps.

Compatible with high-intensity UltrAA lamps.

 

Lamps secured by the base without restraining clips or power cables. Lamps automatically switched off at the end of analysis. Users can elect to leave the lamp on at the end of an autorun. Automated pre-warming of next lamp in sequence.

 

Optional UltrAA lamp looming available

 

Background corrector

High-intensity deuterium background corrector covering wavelength range 185-425 nm. Corrects up to 2.5 background absorbance. 2 ms response. Electronic modulation with automatic gain attenuation for improved beam balance. Deuterium lamp easily aligned and replaced by the user.

 

Internal air purge

Barb fitting provided on rear of spectrometer module to enable connection to a supply of clean, dry air. This enables internal purging of the instrument to maintain a positive flow of clean air through the instrument. This excludes dust and corrosive vapors, enhancing corrosion protection in rigorous conditions

 

FS operation

Supports Fast Sequential operation, enabling multiple elements to be measured in rapid sequence in a single sample measurement, without the need to re-analyze the samples for subsequent elements.

Requires PRO software (optional on AA240).

 

Gas control

Hammer programmable gas control standard.

 

Automatic gas control – preset oxidant flow and variable fuel flow adjusted using manual flow meter adjustments. Automatic oxidant change-over.

 

Hammer programmable gas control – PC-controlled gas flows with automatic setting of gas flows for each element. Automatic oxidant changeover. Features unique fast response Hammer solenoid valve for rapid regulation and setting of selected gas flow.

 

Flame safety system

Separate ignite and flame-off buttons. Eight safety interlocks monitor burner type, burner correctly fitted, liquid trap, pressure relief bung, flame shield, flame operation, mains power, oxidant safety reservoir and deuterium lamp cover. Internal gas connections made automatically without external gas hoses. Separate upper and lower flame shields and a chimney protect against heat and UV radiation from the   flame . External adjustment of all burner and spray chamber controls. Violation of any safety interlock eighter inhibits flame ignition or extinguishes existing flame.

 

Burner adjuster

Manual adjustment of burner height.

 

Flame atomization

Universal Mark 7 atomization system supplied as standard.

 

Spray chamber

Fluorinated high density polyethylene Mark 7 design suitable for aqueous and organic solutions.

 

Mixing paddles

Removable twin-headed mixing paddles fitted inside the spray chamber for better mixing and extended operation with high dissolved solids solutions.

 

Impact bead

Externally adjustable glass impact bead for optimum sensitivity and best precision.

Optional Teflon bead for HF applications

 

Nebulizer

Adjustable nebulizer with inert platinum/iridium capillary and PEEK venture for corrosion resistance.

 

Liquid trap

Integral liquid trap with magnetic float interlock.

 

Burner

Incoloy air/acetylene burner with Teflon corrosion shield. Provides external burner rotation. Optional nitrous-oxide/acetylene burner.

 

Typical performance

Absorbance > 0.9 with precision of < 0.5 % RSD from ten 5 second integrations for 5 mg/L Cu standard.

 

 

 

Recommended environmental conditions

 

Instrument storage:

5-45 °C at 20-80 % relative humidity, non condensing.

 

Instrument operation:

< 853 m, 10-35 °C, 8-80 % relative humidity, non condensing.

853-2133 m, 10-25 °C, 8-80 % relative humidity, non condensing.

 

Electrical requirements for AA140/240/280

Mains supply 100/120/220/240 VAC ±10%, 230 VAC +14% -6%, 230 VAC +6% -14%

50 or 60 Hz ±1 Hz. Power requirements detailed in following table.

 

Gas requirements for flame operation

Air supply

Clean, dry and oil-free at pressure of 245-455 kPa (35-65 psi).

Recommended pressure 350 kPa (50 psi). Typical consumption 13.5-20 L/min.

 

Acetylene supply

Instrument grade (99.0% pure) packaged in acetone at pressure of 65-100 kPa (9.5-14.5 psi). Recommended pressure 75 kPa (11 psi). Typical consumption 1.5-8.0 L/min.

 

Nitrous oxide

Instrument grade (99.5% pure) at pressure of 245-455 kPa (35-65 psi). Recommended pressure 350 kPa (50 psi). Typical consumption 11-16 L/min.

 

Fume extraction

Spectrometer must be located under an extraction system providing flow of at least 6 cubic metres/min (200 cfm) at 16 mm water gauge static pressure. Exhaust must be ducted to an external vent.

 

Electrical requirements for AA240/280 Zeeman and GTA120/GTA-110

208-240 VAC ±10%, 50 or 60 Hz ±1 Hz. Rated current 15 A single phase.

Surge current of up to 40 A for approx. 1 sec. reducing to 20 A for up to 10 sec. in any 1 or 2 minute period. Power requirements detailed in following table.

 

Cooling water requirements for GTA120/GTA-110

Mains supply or recirculated (preferred) with flow rate of 1.5-2 L/min at 175-210 kPa (25-30 psi).

Maximum pressure 210 kPa (30 psi). Recommended temperature range 18-25 °C (65-78 °F).

Maximum permissible temperature 40 °C (104 °F).

 

Gas requirements for GTA120/GTA-110

Argon or nitrogen (dry 99.99% argon preferred) at pressure of 140-200 kPa (20-29 psi).

Recommended pressure 140 kPa (20 psi). Maximum consumption 3.8 L/min (3.1 L/min. for GTA-110).

 

Gas requirements for VGA-77

Argon or nitrogen (dry 99.99% argon preferred) at pressure of 300-400 kPa (42-57 psi).

Recommended pressure 300 kPa (42 psi). Maximum consumption 0.1 L/min.

 

 

 

Weights, dimensions and power requirements

 

AA140/240/240 FS

 

Weights

Unpacked kgs (lbs)            56 (123)

Packed kgs (lbs)                97 (214)

 

Dimensions

Unpaced (W x D x H) cm (inches)

79 x 58 x 59 (31 x 23 x 23)

 

Power Consumption VA

170