Atomic absorption spectrometers

PEAK Instruments AA2928

€17,739.00
Excl. 19% VAT , excl. Shipping Cost
€21,109.41 incl. Vat
ID-number: 42327
Status: New Device?This is a new device. The equipment is unused and factory sealed. For new equipment the warranty of the manufacturer and the statutory warranty period shall apply.
Shipping: 4-6 weeks
Description:
PEAK Instruments Dual Jet Flame AAA AA2928.
Holographic diffraction grating with 1800 lines/mm.
Slits: 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm.
Wavelength range: 190-900 nm, accuracy: ±0.15 nm.
Automated 8 lamp tower.
Detector: UV sensitive photomultiplier tube.
Reading mode: Transmission (T), Absorption (A), Concentration (C).
Background correction: deuterium (D2) and self-absorption.

NEW DEVICE!
Installation
We execute the installation of this laboratory device professionally. We would be pleased to offer you the installation of this laboratory device for 1120€, excluding travel expenses.

Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.


We would be pleased to take over the professional installation of your laboratory devices!

Please contact us.


Benefit from the installation by us in more than one way:

  • Immediate and smooth startup of your laboratory device
  • A professional installation extends the lifetime of your laboratory device
  • Guarantee extends to 3 months
  • Freight charges do not apply*
  • You are entitled to benefit from the Labexchange Repurchase Guarantee.

* products of the product groups laboratory furniture and laminar flow are excluded. In individual cases, other product groups can be excluded.


Add to Offer List
More Information
Objektnummer B00042327
ID-number 42327
Object name PEAK Instruments AA2928
Status Neugerät
Manufacture PEAK Instruments
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

manufacturer:     PEAK Instruments

model:                  AA2928

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery.

Please refer to the text of the offer for the exact scope of delivery.

Main Features

  • Automatic vertical 4/8-lamp turret supports high-performance element lamp, can be rotated 360 degrees and make sure the test accuracy and reliability is not affected by the gravity.
  • Automatic burner adjustment ensures the maximum sensitivity, you can raise or lower the burner according to the reading. Flame detection enhances the device safety.
  • Modular design for optical system and circuit makes the maintenance and repair simple.
  • Total reflection optical system can reduce energy loss to ensure better signal-to-noise ratio and lower detection limit.
  • Standard deuterium lamp background correction for all models. Standard high-performance self-absorption background correction for double beam models, and optional for the models with 8-lamp turret.
  • Automatic pneumatic control module ensures the device safety and accuracy and protects the operator and device better.
  • Safety protection system: flame monitoring (acetylene will be turned off automatically if there is any abnormality and show warning information), unique acetylene protector (warning information will be shown if the leak acetylene concentration is beyond the alert concentration), pressure monitoring (the flame will not work if the air or acetylene pressure is not normal, the graphite furnace will not work if the argon pressure is too high or too low), graphite tube installation self-inspection.
  • Professional, automatic and easy to operate full operation RGWIN AAS software under MS window system and QA/QC function.
  • Transversely heated graphite tube ensures the consistency of the gas temperature in the graphite tube, and make the sample reach the atomic temperature instantly and simultaneously, improve atomic efficiency and test accuracy, ensure that the analysis results are more accurate, reduce the requirements for furnace body and prolong lifetime.
 
 
Model
AA2914
AA2918
AA2928
Optical System Optical Type
Single beam
Single beam
Double beam
Monochromator
Czerny-Turner type with focal lengths at 350mm
Wavelength Range
190-900nm
Grating
Holographic diffraction grating with 1800 lines/mm
Slits
Automated slit selection 0.1,0.2,0.4,0.7,1.4,2.0 nm
Wavelength Accuracy
±0.3 nm
±0.2 nm
±0.15 nm
Wavelength Repeatability
±0.1 nm
±0.1 nm
±0.05 nm
Lamp Holder
Automated 4-lamp turret
Automated 8-lamp turret
Detector
Wide range UV sensitive photomultiplier tube
Photometric Performance Reading Mode
Transmittance(T), Absorbance(A), Concentration(C)
Photometric Range
0-125%, -0.1-3.00A
Static Baseline Drift (Cu)
≤0.004A/30 min
≤0.003A/30 min
≤0.002A/30 min
Dynamic Baseline Drift (Cu)
≤0.006A/15 min
≤0.005A/15 min
≤0.004A/15 min
Background Correction
Deuterium (D2) Background Correction
D2 and Self-absorption
Flame Analysis Characteristic Concentration
Cu≤0.04ug/ml
Cu≤0.035ug/ml
Cu≤0.02ug/ml
Detection Limit
Cu≤0.008ug/ml
Cu≤$0.006ug/ml
Cu≤0.004ug/ml
Repeatability (Cu)
RSD≤1%
RSD≤0.6%
RSD≤0.5%
Acetylene Flow Control
Auto 12-level
Auto 12-level
Auto 12-level
Air Flow Control
Auto 4-level
Auto 4-level
Auto 4-level
Nebulizer
High efficiency glass
Burner Adjustment
Automatic up and down
Burner Head
Titanium alloy 100mm burner for air/acetylene operation
Premix Chamber
Corrosion resistant
Safety Protection
Flame sensor, gas leak sensor, gas pressure sensor
Data Processing Software
RGWIN AAS software pacakage
Analytical Method
Flame AA, Flame AE, Hydride Generation
Concentration Calculation Method
Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation
Repeated Measurement Times
1-30 times, calculate the average, show SD and RSD value of absorbance and concentration
QA/QC Function
Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration
Report Printing
Parameter printing, resulting printing
Communication Port
Standard RS-232
Others Computer
External (excluded)
Dimension & Weight
(W*D*H), Kg
Power Supply
110/220V, 50/60HZ
Working Environment
Temperature 10 ~ 35 °C, Humidity≤85%

Product group: AAS

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure