JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
24 months legal warranty
60 days Labexchange Fullguarantee
Certificate of operativeness
The Labexchange right of return
Optional installation of equipment for immediate and safe use of equipment
Questions regarding this device
If you buy this item used instead of new, you save as much CO2 as driving 1850 km with a gasoline car.
The legal warranty period for our devices is 24 months from delivery date.
All used instruments of Labexchange are subject to a technical inspection before delivery and will be supplied only, when they function perfectly well. The verification and functionability is documented by a service report of an independent service company. The Labexchange Fullguarantee is 60 days from delivery date. Malfunctions occurring within the warranty period will be corrected by us free of charge. (Valid for countries within the EU and CH)
Our certificate of operativeness ensures a technically perfect condition.
You are on the safe side with our used laboratory and analysis systems! For even more security during the purchase, we are granting the Labexchange right of return.
Return your laboratory or analysis system simply without explanation.
Our special terms and conditions are to be applied:Labexchange right of return(https://www.labexchange.com/fileadmin/user_upload/pdf/downloads/en/Rueckgaberecht_08_18_E.pdf)
On demand, we verify the option of an extension of warranty for your device. If possible, the period of warranty is 6 months for 10 % extra charge and 1 year for 20 % extra charge on the list price. (Valid for DE, AT, CH, FR, NL, BE, LU, GB and IR)
Play it safe! We are pleased to offer you the installation of your laboratory equipment. Our qualified technicians install the device on your desired date in the laboratory, so that you can work quickly and safely with your new laboratory equipment.
The installation of the equipment by Labexchange brings further advantages. You thereby obtain a guarantee extension to 6 months and you have also the right to the Labexchange Repurchase Guarantee. You receive sensible laboratory equipment and analytical systems as well as much of the available laboratory hoods, already incl. installation.
* Required Fields
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country
Possible payment methods
Comment
DE, AT, CH
Payment by invoice, payment in advance
Payment by invoice is only possible for corporate clients.
NL, BE, LU
Payment by invoice is only possible for corporate clients
Other countries
Payment in advance
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
All articles are used articles, except an article is listed especially as a new device.
Status
Condition
Immediately available
Used
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.
Published
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.
New device
new
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.
Model: Casy model TT
The following illustrations and descriptions are model-specific and taken from brochures.
They do not reflect the scope of delivery of the system.
The exact scope of delivery can be found in the offer text.
System data:
O High-resolution size distribution - 400 size channels displayed,
O Exact and fast determination of the concentration and volume of cells and particles.
O Simultaneous analysis of all size classes in the measuring range of the measuring capillary with maximum dynamic of the measurement> 1: 70,000 in volume.
O Differentiation of vital cells, dead cells, cell debris and cell aggregates. - Statistical certainty of results through cumulative multiple measurements.
O Reliable measurement of the smallest cell numbers - less than 100.
O Electronic monitoring of the measurable.
O Opto-electronically controlled volume measuring section - maintenance-free.
O Quick sample change through open, large sample space.
O Quick change of the measuring capillary - approx. 30 sec.
Technical data CASY model TT
Function: Electronic cell counter + analyzer system for determination
of cell number and cell size distribution, aggregation and vitality.
Dimensions: Height: 39 cm
Width: 31 cm
Depth: 39 cm
Weight: 14.5 kg (including control element)
Environmental conditions: maximum operating temperature: 10 ° C to 40 ° C
recommended operating temperature: 15 ° C to 32 ° C
Power supply: 230 V- / 50 Hz
115V- / 60 Hz
Power consumption: Max. 112 VA
Fuses (primary): 230V: 2 x 800 mAT
115V: 2 x 1.6 AT
Fuses (secondary): SI1: T 160mA
SI2: T 1.6A
SI3: T 400mA
SI4: T 2.5 A
SI5: T 400mA
Volume measuring section Calibrated , opto-electronically controlled volume measuring section
and printing system: with maintenance-free, sensor-controlled. Printing system. Mercury free.
Measuring principle: Electrical resistance measurement in clocked with 1 MHz
Low-voltage field with pulse area analysis by Sharpness System. Differentiable size channels:> 512,000.
Volume resolution: 1 in 512,000
Displayed size channels: 400
Measuring range: 0.7 µm to 120 µm
Measurement dynamics: Ratio of the smallest to the largest particle that can be analyzed simultaneously:> 1: 70,000 in volume,
> 1:40 in diameter
Typical analysis time: 10 sec
Sample volume: 200 µl - 4 ml
Analytics / Results: Analysis of the size distribution over two tent-specific adjustable cursor pairs:
Cell count: absolute, relative -% -,
Cell vitality: absolute, relative -% -,
Cell aggregates: Aggregation factor, aggregation correction,
Cell volume: Volume, mean volume, total volume (biomass)
Interfaces: Serial, RS232 (DB9)
Parallel (DB25)
Only IEC or UL tested devices may be connected to the RS232 and printer interfaces.
Printer output: PCL (Hewlett-Packard compatible printer)
Expression of: Size distribution
Numerical results
Setups
Error messages
Data export: ASCII, fully automatic transfer to MS-Excel "" with CASY excell.
Technology features:
Non-changeable, long-term stable calibration for biological media - certified by Sharp System, identical for all CAS1r devices, documentation of the measurement results with date, time, setup name, device serial number and all device settings.
System self-test with checking of all measurement-relevant parameters before and during each measurement.
Electronic monitoring of the measuring pore.
Automatic backwashing of the measuring pore.
Automatic detection and display of operating and system errors. Integrated service functions for quick fault diagnosis.
Fan-free system suitable for clean rooms.
Service: Menu-guided operation and control of all functions via a freely positionable control element with membrane keyboard and graphic display. All tent-specific device settings can be saved as a setup.
20 setups per measuring capillary - individually nameable.
Output of the results and the size distribution on the display and printer. Export function for computers via the serial interface.
Maintenance: CASY ° is largely maintenance-free with regular maintenance. If maintenance is necessary or requested by the user, contact Scharme System or the dealer responsible for you. Maintenance measures may only be carried out by specialists who have been trained and authorized by Schleiß System.
Your Labexchange-Team will gladly help:
Christian Schmid Laboratory and analysis, Laboratory equipment, Life science
Hubert Sauter Spectroscopy, Chromatography