Shimadzu 8400S

Shimadzu 8400S
€ 7.600,00
excl. BTW
€ 9.044,00 incl. BTW

ID-Nr: 32518

Status: op voorraad  

Verzending: 10-14 werkdageni

Installation
We execute the installation of this laboratory device professionally. We would be pleased to offer you the installation of this laboratory device for 580€, excluding travel expenses. >>>


Professional installations of your laboratory devices


Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.


We would be pleased to take over the professional installation of your laboratory devices!

Please contact us.


Benefit from the installation by us in more than one way:

  • Immediate and smooth startup of your laboratory device
  • A professional installation extends the lifetime of your laboratory device
  • Guarantee extends to 3 months
  • Freight charges do not apply*
  • You are entitled to benefit from the Labexchange Repurchase Guarantee.

* products of the product groups laboratory furniture and laminar flow are excluded. In individual cases, other product groups can be excluded.



Beschrijving:
Shimadzu FTIR 8400S.
Met pc en vooraf geïnstalleerde software.
Barst in de voorkant.

* Vereiste velden

€ 7.600,00
of
Aanvullende Informatie

Aanvullende Informatie

Seriennummer 32518
Object Naam Shimadzu 8400S
Soort onroerend go FTIR-Spektrometer-Spektrometer
______
Status op voorraad
Fabrikant Shimadzu
Verzending10-14 werkdagen
Overige producten

Product groep: FTIR-spectrometer

Status, leverings- en betalingsvoorwaarden

Status, leverings- en betalingsvoorwaarden

Apparatuurcontrole

De gebruikte apparatuur wordt voorafgaand aan levering gecontroleerd door Labexchange Service GmbH. U ontvangt volledig functionerende apparatuur.

 

Verzending

De vermelde verzendtijden zijn telkens de kortste voor een artikel. In bepaalde gevallen kunnen de daadwerkelijke verzendtijden daarvan afwijken. De uiteindelijke verzendtijden worden aangegeven in de opdrachtbevestiging.

In de regel bieden we combinatieleveringen aan. Levertijden zijn afhankelijk van het artikel met de langste levertijd. Deelleveringen zijn mogelijk tegen een toeslag.

 

Verzendmethoden

Koeriersdiensten, transportbedrijven, zelf afhalen, levering door eigen wagenpark

 

Informatie levering

De prijzen zijn exclusief verzendkosten. De genoemde verzendkosten zijn de te verwachten kosten. Afwijkingen zijn mogelijk. In het geval geen kosten voor verzending zijn gespecificeerd, vraag die dan afzonderlijk aan.

Voor levering in landen buiten de EU wordt voor export een toeslag van € 70,00 in rekening gebracht. Opmerking: We geven geen preferentieel certificaat/EUR1 af.

 

Betalingsvoorwaarden

Wij accepteren geen betalingen per creditkaart, Letter of Credit, PayPal etc. Het factuurbedrag is volledig verschuldigd. Er zijn geen betalingskortingen. De goederen blijven tot volledige betaling ons eigendom.

Land

Mogelijke betaalmethoden

Opmerking

Duitsland, Oostenrijk, Zwitserland

Betaling via factuur, vooruitbetaling

Betaling via factuur is mogelijk voor ondernemingsklanten.

Nederland, België en Luxemburg

Betaling via factuur, vooruitbetaling

Betaling via factuur is mogelijk voor ondernemingsklanten.

Andere landen

vooruitbetaling

 

 

Onze Algemene Voorwaarden voor Verkoop, Levering en Betaling zijn hierop van toepassing. Deze voorwaarden zijn hier te downloaden.

Tussenverkoop is ons voorbehouden.

 

Beschrijving status:

Alle artikelen zijn gebruikte artikelen, tenzij bij een artikel uitdrukkelijk wordt vermeld dat het om een nieuw apparaat gaat.

Status

Conditie

Opmerking

Onmiddellijk verkrijgbaar

gebruikt Het artikel is al gecontroleerd en is in perfecte staat. Het kan onmiddellijk aan u worden verstuurd.
Op voorraad

gebruikt

We hebben het artikel in ons magazijn. Onze technici zullen het artikel voorafgaand aan levering controleren. U ontvangt volledig functionerende artikel.

Gepubliceerd

gebruikt

Het artikel is nog bij de aanbieder. Na uw bestelling wordt het door ons aangekocht, gecontroleerd en aan u verstuurd. Een functioneringscertificaat en een servicerapport zijn bij de levering inbegrepen.

Nieuw

nieuw

Dit is een artikel dat nieuw van de fabriek komt. Hiervoor gelden de garantiebepalingen en wettelijke garantietermijn van de fabrikant.

Technical Specifications

Company:    Shimadzu

Model:          8400S

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

 

 

Specifications

 

 

 

Hardware (except PC)

 

interferometer

Michelson l nterferometer (30 ° angle of incidence)

Dynamic Alignment System

Sealed and dry Interferometer

 

Optical System

Single beam optics

 

Beamsplitter

Germanium-coated KBr plate

 

Ray source

Ceramics

 

Detector

High-sensitivity detector pryroelektrischer (DLATGS)

 

Wavenumber range

7800 cm -1 - 350 cm -1

 

Resolution

0.85 cm -1, 1 cm -1, 2 cm -1, 4 cm -1, 8 cm -1, 16 cm -1

 

Calculating wave number interval 1

00:25 cm -1, 0.5 cm -1, 1 cm -1, 2 cm -1, 4 cm -1

 

Wavenumber accuracy 1.2

+0.25 Cm -1

 

Signal-to-noise ratio

20000: 1 (peak-to-peak, resolution 4 cm -1, about 2100 cm -1

1 minute scan)

 

Mirror speed

3-stage selection of 2.8 mmlSek., 5 mm / sec. or 9 mm / sec.

A scan at 4 cm -1 takes 2-3 sec.

 

Data sampling

He-Ne laser

 

Gain control

Automatic or manual x 1 - x 128 in 2 n steps

 

Sample compartment

200 (W) x 230 (L) x 170 (H) mm

 

Dimensions / Weight spectrophotometer unit

620 (W) x 580 (L) x 240 (H) mm, 40 kg

 

 

  1. The resolution and wavenumber accuracy of FTIR spectrophotometer are determined by the wave number interval of spectral data (calculating wave number interval). Since the minimal calculated wavenumber interval of FTIR-8400S 0.25 cm -1, the peak position can be read with an accuracy of ± 0.125 cm -1. However asymmetric absorption band reduce the accuracy to ± 0.5 cm -1
  2. Based on the wavelength of the He-Ne laser is the wave number Accuracy ± 0.01 cm -1  

 

 

Note

The FTIR-8400S does not comply with the IEC601-regulation

 

 

 

Software

 

OS

Microsoft Windows 2000 (Service Pack 2 or later). Windows XP Profesional

 

lnterface

SCSI

 

Monitor the hardware

Self-diagnostic function, Status Monitor

Validation program based on USEnglish Pharmacopoeia / Europe Pharmacopoeia (EP) / ASTM

 

Data processing

Addition, subtraction, multiplication, division,% T ↔ para conversion, normalization, baseline correction, Log conversion, smoothing, Derivative, ATR correction, Kubelka-Munk correction, Kramers-Kronig analysis, WellenzahlAlVellenlängen conversion, peak detection, peak area calculation. Film thickness

 

Quantitative processing

Peak height, Peak area, multi-point calibration curve method using ratio, multi-Regression (MLR) method

 

Search range

Search Parameters setting, search the user and commercial library, creation of user library

 

Printing

Report processor function

 

Display

Compression of the wave number axis, enlargement / reduction, Auto Scale, Overlap, stack display, Shift display

 

Editing

Copy, Cut, Paste

 

Others

Adjustment of the graphical user interface

 

Optional Software

Macro programming, PLS quantitation, curve fitting, 3DDisplay, mapping measurement

 

Audit trail

Ensures samples / background interferogram and data processing history

User management with password and create a user group

Log record

The function complies with FDA 21CFR part of 11 match

 

 

 

Others

 

lnstallationsort

Temperature: 15 to 30 ° C

Moisture. 70% or less, no dew condensation

 

Utility (Note 1)

100/120/220/230 VAC, 50/60 Hz, 160 VA

 

Note 1

The electricity for the computer is required separately.