Perkin Elmer Optima 2000DV

Seriennummer: 019043
Status Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Beschrijving:
Perkin Elmer ICP OES Optima 2000DV. Autosampler AS520X. Torch. Atomizer. For operation, argon 5.0, power and cooling water is necessary. Chillers not included in the offer. Software for control and evaluation on CDRom. Vers 3.3.1. The last time run under WinXP. Regularly maintenance. Duration of the maintenance contract until autumn 2010. Device was previously used to study agricultural samples
Quotation
siehe Storeview
Meer informatie
Objektnummer B00019043
Seriennummer 019043
Object Naam Perkin Elmer Optima 2000DV
Status Stock unit

Product groep: ICP systemen

Geen producten gevonden voor deze selectie.

Status, leverings- en betalingsvoorwaarden

Apparatuurcontrole

De gebruikte apparatuur wordt voorafgaand aan levering gecontroleerd door Labexchange Service GmbH. U ontvangt volledig functionerende apparatuur.

 

Verzending

De vermelde verzendtijden zijn telkens de kortste voor een artikel. In bepaalde gevallen kunnen de daadwerkelijke verzendtijden daarvan afwijken. De uiteindelijke verzendtijden worden aangegeven in de opdrachtbevestiging.

In de regel bieden we combinatieleveringen aan. Levertijden zijn afhankelijk van het artikel met de langste levertijd. Deelleveringen zijn mogelijk tegen een toeslag.

 

Verzendmethoden

Koeriersdiensten, transportbedrijven, zelf afhalen, levering door Labexchange wagenpark

 

Informatie levering

De prijzen zijn exclusief verzendkosten. De genoemde verzendkosten zijn de te verwachten kosten. Afwijkingen zijn mogelijk. In het geval geen kosten voor verzending zijn gespecificeerd, vraag die dan afzonderlijk aan.

De opgegeven vracht- en verpakkingskosten hebben betrekking op de goedkoopste transportroute en zijn onder voorbehoud van onvoorziene kostenstijgingen. Door onvoorziene gebeurtenissen kunnen vrachttarieven en levertijden op elk moment veranderen en moeten ze worden aangepast aan de huidige situatie. Incoterm coderingen volgens Incoterms 2010: Bij afhalen EXW, CFR voor zendingen over zee, CPT per luchtfracht, andere zendingen DAP. Opmerking: We geven geen preferentieel certificaat/EUR1 af. Bij zelf afhalen/af fabriek (EXW) uit derde landen en de EU wordt 16% btw als borg ingehouden, tot we de ontvangstbevestiging/het leveringscertificaat van de koper hebben ontvangen.

 

Betalingsvoorwaarden

Wij accepteren geen betalingen Letter of Credit, PayPal etc. Het factuurbedrag is volledig verschuldigd. Er zijn geen betalingskortingen. De goederen blijven tot volledige betaling ons eigendom.

Land

Mogelijke betaalmethoden

Opmerking

Duitsland, Oostenrijk, Zwitserland

Betaling via factuur, vooruitbetaling, per creditkaart

Betaling via factuur is mogelijk voor ondernemingsklanten.

Nederland, België en Luxemburg

Betaling via factuur, vooruitbetaling, per creditkaart

Betaling via factuur is mogelijk voor ondernemingsklanten.

Andere landen

vooruitbetaling, per creditkaart

 

 

Onze Algemene Voorwaarden voor Verkoop, Levering en Betaling zijn hierop van toepassing. Deze voorwaarden zijn hier te downloaden.

Tussenverkoop is ons voorbehouden.

 

Beschrijving status:

Alle artikelen zijn gebruikte artikelen, tenzij bij een artikel uitdrukkelijk wordt vermeld dat het om een nieuw apparaat gaat.

Status

Conditie

Opmerking

Onmiddellijk verkrijgbaar

gebruikt Het artikel is al gecontroleerd en is in perfecte staat. Het kan onmiddellijk aan u worden verstuurd.
Op voorraad

gebruikt

We hebben het artikel in ons magazijn. Onze technici zullen het artikel voorafgaand aan levering controleren. U ontvangt volledig functionerende artikel.

Gepubliceerd

gebruikt

Het artikel is nog bij de aanbieder. Na uw bestelling wordt het door ons aangekocht, gecontroleerd en aan u verstuurd. Een functioneringscertificaat en een servicerapport zijn bij de levering inbegrepen.

Nieuw

nieuw

Dit is een artikel dat nieuw van de fabriek komt. Hiervoor gelden de garantiebepalingen en wettelijke garantietermijn van de fabrikant.

Labprocure

gebruikt

Labprocure GmbH is verantwoordelijk voor de inhoud van dit apparaataanbod. Labprocure aanvaardt aansprakelijkheid voor de hier geadverteerde aanbiedingen en voor de daarin opgenomen foto's en aanbiedingsteksten. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Perkin Elmer

model :                   Optima 2000DV

annotation :           Dokumente engl .

 

 

 

 

 

OPTIMA 2000 ICP optical emission spectrometer

 

 

 

Specifications

 

General

The PerkinElmer OPTIMA 2000 TM ICP optical emission spectrometer is a compact, bench-mounted, high-speed scanning CCD-based sequential ICP-OES system. All systems feature dual viewing of the plasma; a free-running 40-MHz solid-state RF generator; a double monochromator ; and a dual backside-illuminated charge-coupled device (DBI-CCD) detector.

 

 

 

 

Spectrometer Specifications

 

Double monochromator

The OPTIMA 2000 ICP-OES uses a unique double- monochromator optical system.The first, or preselection monochromator , selects a small portion of the spectrum around the analytical line of interest. The second, the Echelle -based high-dispersion monochromator , disperses the narrow wavelength range onto the DBI-CCD. This unique design results in a high-speed, high light-throughput optical system offering excellent resolution, all in a compact system. The entire system is shockmounted so that normal floor vibrations do not affect system performance. The sealed optical system can be purged with nitrogen for low UV (<190 nm) performance.

 

Preselection monochromator

The preselection monochromator has a focal length of 0.3 meter and uses a Stigmatic Littrow

configuration . The disperser is a 30-degree CaF 2 prism.

 

Echelle monochromator

The high-dispersion Echelle monochromator also has a focal length of 0.3 meter and a Stigmatic Littrow configuration. The Echelle grating used for dispersion has 79 lines/mm with a blaze angle of 63.8 degrees.

 

Spectrometer parameters

The spectral range is 160–900 nm. The slew rate is less than 3 seconds to cover the spectral

range , and the measured resolution is <0.009 nm @ 200 nm. The prism and Echelle grating are rotated less than ± 2 degrees to access any wavelength, dramatically improving analytical speed.

 

Plasma viewing

The dual-view optics of the OPTIMA 2000 ICP-OES allow the plasma to be viewed radially or

axially . Dual viewing of the plasma provides the best possible combination, allowing for trace and major levels of an element to be determined without having to do extensive methods development at several alternate wavelengths. The OPTIMA 2000 software allows the selection of axial or radial viewing with automatic adjustment of the plasma viewing in both the vertical and horizontal direction.

 

Detector

The UV-sensitive, dual backside-illuminated CCD detector is cooled directly using a single-stage integrated Peltier cooler operated at approximately -8°C. The detector housing is hermetically sealed and is filled with dry nitrogen to eliminate condensation. The detector has two photosensitive segments containing 176 by 128 pixels. One section is used for analytical measurements, and the other is a wavelength reference section. The solid-state detector collects both the analyte spectra and the nearby background spectra, allowing for simultaneous background correction and providing improved precision and analytical speed.

 

Dynamic wavelength correction

The wavelength reference section monitors a full wavelength neon spectrum, creating a dynamic wavelength scale used to actively correct wavelength positions. The resulting wavelength accuracy           and reproducibility allows direct ‘on-peak’ measurements rather than time-consuming peak-search methods used in sequential ICP systems.

 

 

 

 

ICP System Specifications

 

RF generator and coil

The OPTIMA 2000 ICP-OES features a 40-MHz, free-running, solid-state (no power amplifier tube needed) RF generator, adjustable from 750 to 1500 watts, in 1-watt increments. The power efficiency is greater than 75% with <0.1% variation in output power stability. The solid-state components significantly increase reliability and can result in higher signal/power readings than conventional tube generators. The compact RF supply meets all FCC certification requirements for RF emission (Part 18 of FCC Rules and Regulations). It also complies with EC and VDE 0871 Class B requirements.

 

Ignition and power control

Plasma ignition is computer-controlled and totally automated. A unique software feature allows the plasma to be

ignited automatically at a user-determined time to warm up the system prior to an analysis. The plasma can be turned off automatically after an analysis. True power control maintains the plasma power, even when changing sample matrices.

 

Safety interlocks

For user safety and system protection, the system constantly monitors water flow, shear gas pressure, argon pressure, sample compartment door closure and plasma stability, and displays the interlock status on the computer screen as graphic symbols. If an interlock is interrupted, the plasma will automatically shut down safely.

 

Cooling water

A water recirculating cooling system is required, with approximately 4 L/min flow capacity at 310 to 550 kPa and a temperature between 15°C and 25°C. A NESLAB CFT 75D or equivalent is recommended.

 

 

 

 

Gas Flow Controls

 

Argon flow     

Computer-controlled solenoid valves are used to regulate the flow automatically within the range of 0-20 L/min in 1-L/min increments for plasma argon and 0 to 2.0 L/min in 0.1-L/min increments for auxiliary argon. A mass flow controller is supplied with all systems for the nebulizer argon flow and is variable between 0 and 2.0 L/min in 0.01-L/min increments.

 

Shear gas

A compressed air shear gas (18-25 L/min) is used to remove the plasma tail from the optical path, minimizing interferences and extending the dynamic range. The shear gas design offers a maintenance-free and lower-cost (no use of Argon) approach to removing the cooler plasma zone.

 

 

 

 

Sample Introduction System

 

Torch

A unique, demountable torch design using one-piece quartz tubing for plasma and auxiliary gas flow is supplied. The standard torch includes a 2.0-mm i.d . alumina injector for full corrosion resistance to all acids, including hydrofluoric and aqua regia . A variety of other injectors are available.

 

Torch mount

The OPTIMA 2000 ICP-OES features a unique, externally mounted spray chamber. The mount can be adjusted (with the plasma on) for maximum performance in different matrices. Unlike other external spray chambers, which can drift with room temperature, the OPTIMA 2000 torch mount is enclosed in a thermally controlled area outside of the torch compartment. No tools are required for torch or sample introduction removal.

 

Spray chamber

The OPTIMA 2000 offers multiple sample introduction systems for complete flexibility. The standard Scott spray chamber is made from inert carbon-filled polyphenylene sulfide (PPS) for complete corrosion resistance to most acids, including HF. A glass cyclonic spray chamber is available and is typically used for high-performance trace elemental analyses.

 

Nebulizer

Both a cross-flow and a concentric nebulizer are available. The GemTip TM cross-flow nebulizer is manufactured from corrosion-resistant materials [sapphire/ruby tips in a polyetheretherketone (PEEK) body]. The system can routinely handle 50% (v/v) solutions of HCl , HNO 3 , H 2 SO 4 , H 3 PO 4 , 20% (v/v) HF and 30% (w/v) NaOH . The system is fully compatible with other sample introduction devices such as ultrasonics , concentrics , and spark ablation.

 

Peristaltic pump

The three-channel, computer-controlled pump has variable speeds from 0.2 to 5 mL /min in 0.1-mL/min increments, using 0.76-mm (0.030 in.) i.d . tubing. Software features include FastPump TM and SmartRinse TM , which dramatically improve the sample rinse-out and analysis times.

 

Spares kit

A spares kit, which includes an assortment of commonly required replacement items and consumables, is included with all Optima TM systems. PerkinElmer offers a complete range of accessories for the OPTIMA 2000.

 

 

 

 

System Specifications

 

Power

200–240 VAC, 30A line (9 amp draw at 240 V), single phase, 50/60 Hz (±1%)

 

Dimensions

132 cm wide x 81 cm high x 76 cm deep

 

Weight

125 kg

 

Environmental

The instrument will operate with a laboratory temperature between 15 and 35 ˚C (59 - 95 ˚F). For optimum instrument performance, the room temperature should be controlled at 20 ±2 ˚C

 