Perkin Elmer ATD 400

Seriennummer: 020212
Status: Archived Product?The unit is no longer available.
Verzending:
Beschrijving:
Perkin Elmer Automatic thermal desorber ATD 400. With control panel. Connecting cable to GC. Cold trap. To operate gas and electricity is needed. Device was previously only about 18 months in the field of R & D in use. Stand-alone device
siehe Storeview
Meer informatie
Objektnummer B00020212
Seriennummer 020212
Object Naam Perkin Elmer ATD 400
Status Archiv

Status, leverings- en betalingsvoorwaarden

Apparatuurcontrole

De gebruikte apparatuur wordt voorafgaand aan levering gecontroleerd door Labexchange Service GmbH. U ontvangt volledig functionerende apparatuur.

 

Verzending

De vermelde verzendtijden zijn telkens de kortste voor een artikel. In bepaalde gevallen kunnen de daadwerkelijke verzendtijden daarvan afwijken. De uiteindelijke verzendtijden worden aangegeven in de opdrachtbevestiging.

In de regel bieden we combinatieleveringen aan. Levertijden zijn afhankelijk van het artikel met de langste levertijd. Deelleveringen zijn mogelijk tegen een toeslag.

 

Verzendmethoden

Koeriersdiensten, transportbedrijven, zelf afhalen, levering door Labexchange wagenpark

 

Informatie levering

De prijzen zijn exclusief verzendkosten. De genoemde verzendkosten zijn de te verwachten kosten. Afwijkingen zijn mogelijk. In het geval geen kosten voor verzending zijn gespecificeerd, vraag die dan afzonderlijk aan.

Voor levering in landen buiten de EU wordt voor export een toeslag van € 70,00 in rekening gebracht. Opmerking: We geven geen preferentieel certificaat/EUR1 af. Bij zelf afhalen/af fabriek (EXW) uit derde landen en de EU wordt 16% btw als borg ingehouden, tot we de ontvangstbevestiging/het leveringscertificaat van de koper hebben ontvangen.

 

Betalingsvoorwaarden

Wij accepteren geen betalingen per creditkaart, Letter of Credit, PayPal etc. Het factuurbedrag is volledig verschuldigd. Er zijn geen betalingskortingen. De goederen blijven tot volledige betaling ons eigendom.

Land

Mogelijke betaalmethoden

Opmerking

Duitsland, Oostenrijk, Zwitserland

Betaling via factuur, vooruitbetaling

Betaling via factuur is mogelijk voor ondernemingsklanten.

Nederland, België en Luxemburg

Betaling via factuur, vooruitbetaling

Betaling via factuur is mogelijk voor ondernemingsklanten.

Andere landen

vooruitbetaling

 

 

Onze Algemene Voorwaarden voor Verkoop, Levering en Betaling zijn hierop van toepassing. Deze voorwaarden zijn hier te downloaden.

Tussenverkoop is ons voorbehouden.

 

Beschrijving status:

Alle artikelen zijn gebruikte artikelen, tenzij bij een artikel uitdrukkelijk wordt vermeld dat het om een nieuw apparaat gaat.

Status

Conditie

Opmerking

Onmiddellijk verkrijgbaar

gebruikt Het artikel is al gecontroleerd en is in perfecte staat. Het kan onmiddellijk aan u worden verstuurd.
Op voorraad

gebruikt

We hebben het artikel in ons magazijn. Onze technici zullen het artikel voorafgaand aan levering controleren. U ontvangt volledig functionerende artikel.

Gepubliceerd

gebruikt

Het artikel is nog bij de aanbieder. Na uw bestelling wordt het door ons aangekocht, gecontroleerd en aan u verstuurd. Een functioneringscertificaat en een servicerapport zijn bij de levering inbegrepen.

Nieuw

nieuw

Dit is een artikel dat nieuw van de fabriek komt. Hiervoor gelden de garantiebepalingen en wettelijke garantietermijn van de fabrikant.

manufacturer :       Perkin Elmer

model :                   ATD 400

annotation :           Dokumente engl .

 

 

 

 

Model ATD 400 Specifications

 

The Model ATD 400 is a microprocessor-controlled, two-stage thermal desorption system. The analysis of up to 50 samples is performed automatically from the desorption of the sarnple tube to the final printed report.

 

The system utilizes a unique electrically-cooled, packed cold trap minimizing the risk of blockages by ice-plug Formation and allowing compatibility with samples containing significant amounts of water. The Model ATD 400 is compatible with any make of gas chromatograph and can be used with all GC column types ranging from ¼ inch packed to narrow-bore capillary.

 

Sample integrity is guaranteed by sealing the sample before and after desorption, and stringent leak test procedures are performed en each tube prior to analysis. The inert system flow path and the wide temperature range (-100 °C to +400 °C) give the Model ATD 400 an unmatched applications capability. Applications include atmospheric monitoring and the determination of volatiles in solids and Iiquids .

 

 

 

 

Stand-alone operation

The instrument is controlled through a keyboard and LCD display unit. Set and actual values of all parameters may be displayed at any time.

 

GC-controlled

When Iinked to Model 8600 or 8700 gas chromatographs configured with an automation board and Revision C or later versions of software, the ATD 400 can be controlled via the GC keyboard.

 

Gas chromatograph/ data system interfacing

BCD output of carousel position.

Contacts for ready and start, and full closed loop operation.

 

Sample tube capacity

50 industry-standard, patented * stainless steel sample tubes. Stainless steel tubes may be fitted with clips accepting adhesive labels for identification. (Removal is not necessary for analysis.) Glass and glass-lined tubes are also available. The sample tube carousel may be recycled repeatedly.

 

* British Patent No. 2064765; U.S. Patent No. 4350037 and equivalent foreign patents

 

 

Method storage

Four desorption methods can be stored in the instrument and "linked" together in sequence if required. (10 desorption methods may be used when the ATD 400 is controlled by a Model 8600 or 8700 gas chromatograph).

 

Desorption modes

Mode 1: Tube conditionirig    

Mode 2: Two-stage desorption

Mode 3: Discontinuous gas extraction

 

No. of desorptions per tube

Up to 99 (when set to 99, the tube is recycled until stopped by the user).

 

 

 

 

Primary Desorption Oven

 

Temp range

50 °C to 400 °C

 

Temp settings

1 degC increments over entire operating range.

 

Desorption time

1.0 min - 30.0 min. Settable in 0.1 min increments.

 

 

 

 

Cold Trap

 

Low temp range

-30 °C to +30 °C ( Peltier cooling) Standard

-100 °C to +30 °C (Liq.N 2 cooling) Optional (Liquid Nitrogen Accessory, L427 0009 * ). Settable in 1 degC increments.

 

* British Patent applied for

 

 

High temp range

50 °C to 400 °C. Settable in 1 deg C increments.

 

Heating rates

Fast (40 degC /s)

Slow (5 degC /s) - for labile sarnple components.

 

Time held at high temp

0.0   to 30.0 min. Settable in 0.1 min increments.

 

Gas flow during trap heating

Forward flow or backflush flow.

 

Material

Quartz

 

NOTE: Gold trap heating may be activated independently to allow trap conditioning.

 

Calibration fadility

Optional gas sampling valve accessory for internal standard introduction. (Standard Injection Accessory, L427 0010.)

 

 

 

 

Transfer Line to Gas Chromatograph

 

Temp range

50 °C to 225 °C. Settable in 1 degC increments.

 

Material

Lined with 0.32 mm i.d . uncoated, deactivated fused silica tubing.

 

 

 

 

Heated Valve

 

Temp range

50 °C to 225 °C. Settable in 1 degC increments.

 

 

 

 

Sample Flow Paths

 

Temp

Maintained at heated valve temperature.

 

Material

Glass-lined stainless steel, PTFE or fused silica.

 

 

 

 

Carrier Gas Pressure Control

 

Pressure controlled supply. Settable from 0 to 30 PSIG (0 to 210 kPa ).

(Maximum inlet pressure 120 PSIG (830 kPa ))

 

 

 

 

Pneumatic Valve Actuation

 

Compressed air at 80 to 120 PSIG (550 to 830 kPa ). Intemal preset pressure control.

Maximum inlet pressure 120 PSIG (830 kPa ).

 

 

 

 

Sample Protection Sequence

 

Initial check for adequate carrier gas supply. Leak and pressure test completed on sample tube and cold trap before tube desorption. Ambient sample purge though the cold trap to remove air from sample tube prior to heating.

 

 

 

 

Sample Splitting

 

Split points available an the inlet and outlet of the cold trap allow independent control of the flow rates during primary desorption, secondary desorption and chromatographic analysis. This multiple splitting capability facilitates the selection of split ratios ranging from zero to

100 000:1.

 

 

 

 

Ambient Conditions

 

Temp range

15 °C to 32 °C

 

Humidity

75% relative humidity without condensation.

 

Power requirements

240 V ±10% 50/60 Hz 1.2 kVA

220 V ±10% 50/60 Hz 1.2 kVA

120 V ±10% 50/60 Hz 1.2 kVA

 

Weight

45.5 kg (100 lb)

 

Unit dimensions

Width               38 cm (15 inches)

Depth               60 cm (23.5 inches)

Height              50 cm (19.5 inches)

 

 

 

 

 

Product groep: GC-overige