Archif

Micromeritics Gemini 2375

Seriennummer: 017505
Status: Archived Product?The unit is no longer available.
Verzending:
Beschrijving:
Micromeritics Analyzer Gemini 2375. For surface determination. With 3 new rehearsing glasses. Without out heating station and vacuum pump. Software Stardriver V. 1.01 for control and analyse. Necessary operating system Win95.
siehe Storeview
Meer informatie
Objektnummer B00017505
Seriennummer 017505
Object Naam Micromeritics Gemini 2375
Status Archiv

Status, leverings- en betalingsvoorwaarden

Apparatuurcontrole

De gebruikte apparatuur wordt voorafgaand aan levering gecontroleerd door Labexchange Service GmbH. U ontvangt volledig functionerende apparatuur.

 

Verzending

De vermelde verzendtijden zijn telkens de kortste voor een artikel. In bepaalde gevallen kunnen de daadwerkelijke verzendtijden daarvan afwijken. De uiteindelijke verzendtijden worden aangegeven in de opdrachtbevestiging.

In de regel bieden we combinatieleveringen aan. Levertijden zijn afhankelijk van het artikel met de langste levertijd. Deelleveringen zijn mogelijk tegen een toeslag.

 

Verzendmethoden

Koeriersdiensten, transportbedrijven, zelf afhalen, levering door Labexchange wagenpark

 

Informatie levering

De prijzen zijn exclusief verzendkosten. De genoemde verzendkosten zijn de te verwachten kosten. Afwijkingen zijn mogelijk. In het geval geen kosten voor verzending zijn gespecificeerd, vraag die dan afzonderlijk aan.

De opgegeven vracht- en verpakkingskosten hebben betrekking op de goedkoopste transportroute en zijn onder voorbehoud van onvoorziene kostenstijgingen. Door onvoorziene gebeurtenissen kunnen vrachttarieven en levertijden op elk moment veranderen en moeten ze worden aangepast aan de huidige situatie. Incoterm coderingen volgens Incoterms 2010: Bij afhalen EXW, CFR voor zendingen over zee, CPT per luchtfracht, andere zendingen DAP. Opmerking: We geven geen preferentieel certificaat/EUR1 af. Bij zelf afhalen/af fabriek (EXW) uit derde landen en de EU wordt 16% btw als borg ingehouden, tot we de ontvangstbevestiging/het leveringscertificaat van de koper hebben ontvangen.

 

Betalingsvoorwaarden

Wij accepteren geen betalingen Letter of Credit, PayPal etc. Het factuurbedrag is volledig verschuldigd. Er zijn geen betalingskortingen. De goederen blijven tot volledige betaling ons eigendom.

Land

Mogelijke betaalmethoden

Opmerking

Duitsland, Oostenrijk, Zwitserland

Betaling via factuur, vooruitbetaling, per creditkaart

Betaling via factuur is mogelijk voor ondernemingsklanten.

Nederland, België en Luxemburg

Betaling via factuur, vooruitbetaling, per creditkaart

Betaling via factuur is mogelijk voor ondernemingsklanten.

Andere landen

vooruitbetaling, per creditkaart

 

 

Onze Algemene Voorwaarden voor Verkoop, Levering en Betaling zijn hierop van toepassing. Deze voorwaarden zijn hier te downloaden.

Tussenverkoop is ons voorbehouden.

 

Beschrijving status:

Alle artikelen zijn gebruikte artikelen, tenzij bij een artikel uitdrukkelijk wordt vermeld dat het om een nieuw apparaat gaat.

Status

Conditie

Opmerking

Onmiddellijk verkrijgbaar

gebruikt Het artikel is al gecontroleerd en is in perfecte staat. Het kan onmiddellijk aan u worden verstuurd.
Op voorraad

gebruikt

We hebben het artikel in ons magazijn. Onze technici zullen het artikel voorafgaand aan levering controleren. U ontvangt volledig functionerende artikel.

Gepubliceerd

gebruikt

Het artikel is nog bij de aanbieder. Na uw bestelling wordt het door ons aangekocht, gecontroleerd en aan u verstuurd. Een functioneringscertificaat en een servicerapport zijn bij de levering inbegrepen.

Nieuw

nieuw

Dit is een artikel dat nieuw van de fabriek komt. Hiervoor gelden de garantiebepalingen en wettelijke garantietermijn van de fabrikant.

Labprocure

gebruikt

Labprocure GmbH is verantwoordelijk voor de inhoud van dit apparaataanbod. Labprocure aanvaardt aansprakelijkheid voor de hier geadverteerde aanbiedingen en voor de daarin opgenomen foto's en aanbiedingsteksten. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Micromeritics

model :                   Gemini 2375

annotation :           Dokumente engl.

 

 

Attention: This is description for Gemini II 2370. The Models are identical.

 

 

The Gemini Analyzer is an easy to use, fully automatic, single- or multi­point surface area analyzer. Once an analysis is started, data are collected, cal­culations performed, and results displayed without further Operator intervention. The frequent calibrations associated with presently available flow­ing-gas systems are not required. The analyzer may be operated in any of live languages: English, French, German, Italian, or Spanish.

Gemini provides rapid and accurate sample analysis, including selectable cal­culation of the following sample characteristics:

n          Single-point BET surface area

n          Multi-point BET surface area

n          Multi-point Langmuir surface area

n          t-Method micropore volume and area

n          Total pure volume

As nue as 50 data points can be collected and reported in the BET, Lang­muir, or t-Method range. Additionally, Gemini can report discrete point ad­sorption isotherms consisting of up to 1,000 adsorption points.

Up to ten Run Conditions Sets (Setup Groups) can be stored, enabling you to perform custom analyses with just a few keystrokes.

Analysis results can also be edited by specifying which points are to be included in surface area or t-Method calculations. Gemini automatically recal­culates the results and generates a new report. Reports remain available for viewing or printing until anotheianalysis is started. Results can also be trans­mitted to a remote location or computer via the standard RS-232 connector.

The Gemini Analyzer, shown in the following Illustration, contains a sample station and an attached keypad and display. The analyzer is controlled by commands entered through the keypad. The operational status of the analyzer can be continually monitored an the display.

 

 

The primary function of the Gemini is to deterrnine the surface area of solid materials. lt uses a flowing-gas technique in which the analysis gas flows into a tube containing the sample and into a balance tube, at the same time. The internal volume and the temperature surrounding both tubes are main­tained at identical conditions. The only difference is the presence of the sample in the sample tube.

The sample and balance tubes are immersed in a single liquid nitrogen bath which maintains isothermal conditions for both tubes. The analysis gas is then delivered•to the sample tube by a servo valve mechanism. The delivery rate of analysis gas flow into the balance tube is controlled by another servo valve connected to a differential pressure transducer. This differential pressure transducer measures the pressure imbalance between the sample and balance tubes, which is caused by the adsorption of the analysis gas onto the sample. As the sample adsorbs analysis gas, the pressure drops in the sample tube. The servo valve continuously restores the pressure balance between two tubes by admitting more gas into the sample tube. The end result is that the Gern­ini maintains a constant pressure of analysis gas over the sample while vary­ing the rate of analysis gas delivery to exactly match the rate at which the sample can adsorb the gas.

 

APPLICABILITY

Surface Area:                       0.1 m 2 to above 300 m 2 , total;

                                            0.01 m 2 /g and higher, specific

Pore Volume:                       4 x 10 -6 cm 3 /g and higher

 

PRESSURE MEASUREMENT

Range:                                 0 to 950 mmHg

Minimum Resolvable

Relative Pressure (P/Po):    10 -4

Pressure Resolution:           0.1 mmHg

Accuracy and Linearity:       Better than ±0.5%

(Transducer manufacturer's

specification )

 

VACUUM SYSTEM

External:                               Vacuum source achieving better than 20 x 10 -3 mmHg at the instrument inlet, and having a device to reduce oil vapor backstrearning is recommended.

The system should also have an anti­suckback valve to prevent oil from being admitted into the Gemini should there be a power failure.

 

ENVIRONMENT

Temperature:                       10 to 35 °C (50 to 96 °F) operating

                                            0 to 50 °C (32 to 122 °F) non-operating

Humidity:                              20% to 80% relative, non-condensing

 

SAMPLE TUBES

Standard Tube:                    The standard tobe has a 0.95-cm (3/8-in.)

outside diameter and is 15.5 cm (6.1 in.) long with 6.5 cm 3 of volume. Sample capacity is approximately 2.0 cm 3 .

Large Tube:                          The bulb of the large tube has a 1.9-cm

(3/4-in.) outside diameter and is 3.8 cm (1-1/2 in.) long. The tube is 15.5 cm (6.1 in.) long. Tt yields a 12.0-cm 3 volume. Sample capacity is approximately 6.0 cm 3 .

 

ELECTRJCAL

Voltage:                                85 to 264 VAC

Frequency:                           47 to 440 Hz

Power:                                  75 VA maximum

 

GASES

Adsorbate

Optimized for nitrogen in a liquid nitrogen sample bath. Gemini may be used with non­ . corrosive adsorbate gases having vapor pressures at both room and bath temperatures that are acceptably high relative to the resblution of the 1,000 mmHg pressure transducer. Typically, oxygen, argon, carbon dioxide, butane, methane, and other light hydrocarbons will produce useful data above absolute

pressures of a few mmHg.

 

PHYSICAL

Height:                                52.4 cm (20.6 in.)

Width:                                 43.8 cm (17.3 in.)

Depth:                                30.5 cm (12.0 in.)

Weight:                               22 kg (48.4 lbs)

Product groep: Meetsystemen voor specifieke toepassingen