N/Nox analyzer

Leco FP-528

Speciale prijs € 4.080,00
-15%
Korting
until 31 mei 2024
Normale prijs € 4.800,00
Excl. 19% VAT , excl. Shipping Cost
€ 4.855,20 incl. Vat
Seriennummer: 41021
Status: Provider?The device is still with the provider. After your order is processed the device is purchased and checked by us. You get the device completely checked and with the Labexchange® full guarantee and a warranty certificate . The delivery time for this product is usually four to six weeks.
Verzending: 4-6 weken
Beschrijving:
Leco Stikstof/Eiwit Analyser FP-528.
Met: Sampler.
persoonlijke computer Software.
Andere accessoires.
Toevoegen aan offertelijst
Meer informatie
Objektnummer B00041021
Seriennummer 41021
Object Naam Leco FP-528
Status Anbieter
Fabrikant Leco
Verzending 4-6 weken

Status, leverings- en betalingsvoorwaarden

Apparatuurcontrole

De gebruikte apparatuur wordt voorafgaand aan levering gecontroleerd door Labexchange Service GmbH. U ontvangt volledig functionerende apparatuur.

 

Verzending

De vermelde verzendtijden zijn telkens de kortste voor een artikel. In bepaalde gevallen kunnen de daadwerkelijke verzendtijden daarvan afwijken. De uiteindelijke verzendtijden worden aangegeven in de opdrachtbevestiging.

In de regel bieden we combinatieleveringen aan. Levertijden zijn afhankelijk van het artikel met de langste levertijd. Deelleveringen zijn mogelijk tegen een toeslag.

 

Verzendmethoden

Koeriersdiensten, transportbedrijven, zelf afhalen, levering door Labexchange wagenpark

 

Informatie levering

De prijzen zijn exclusief verzendkosten. De genoemde verzendkosten zijn de te verwachten kosten. Afwijkingen zijn mogelijk. In het geval geen kosten voor verzending zijn gespecificeerd, vraag die dan afzonderlijk aan.

Voor levering in landen buiten de EU wordt voor export een toeslag van € 70,00 in rekening gebracht. Opmerking: We geven geen preferentieel certificaat/EUR1 af. Bij zelf afhalen/af fabriek (EXW) uit derde landen en de EU wordt 16% btw als borg ingehouden, tot we de ontvangstbevestiging/het leveringscertificaat van de koper hebben ontvangen.

 

Betalingsvoorwaarden

Wij accepteren geen betalingen per creditkaart, Letter of Credit, PayPal etc. Het factuurbedrag is volledig verschuldigd. Er zijn geen betalingskortingen. De goederen blijven tot volledige betaling ons eigendom.

Land

Mogelijke betaalmethoden

Opmerking

Duitsland, Oostenrijk, Zwitserland

Betaling via factuur, vooruitbetaling

Betaling via factuur is mogelijk voor ondernemingsklanten.

Nederland, België en Luxemburg

Betaling via factuur, vooruitbetaling

Betaling via factuur is mogelijk voor ondernemingsklanten.

Andere landen

vooruitbetaling

 

 

Onze Algemene Voorwaarden voor Verkoop, Levering en Betaling zijn hierop van toepassing. Deze voorwaarden zijn hier te downloaden.

Tussenverkoop is ons voorbehouden.

 

Beschrijving status:

Alle artikelen zijn gebruikte artikelen, tenzij bij een artikel uitdrukkelijk wordt vermeld dat het om een nieuw apparaat gaat.

Status

Conditie

Opmerking

Onmiddellijk verkrijgbaar

gebruikt Het artikel is al gecontroleerd en is in perfecte staat. Het kan onmiddellijk aan u worden verstuurd.
Op voorraad

gebruikt

We hebben het artikel in ons magazijn. Onze technici zullen het artikel voorafgaand aan levering controleren. U ontvangt volledig functionerende artikel.

Gepubliceerd

gebruikt

Het artikel is nog bij de aanbieder. Na uw bestelling wordt het door ons aangekocht, gecontroleerd en aan u verstuurd. Een functioneringscertificaat en een servicerapport zijn bij de levering inbegrepen.

Nieuw

nieuw

Dit is een artikel dat nieuw van de fabriek komt. Hiervoor gelden de garantiebepalingen en wettelijke garantietermijn van de fabrikant.

Firma:                Leco

Modell:              FP-528

Kommentar:      Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

FP-528

Description

The FP-528 is designed for smaller sample weights and is controlled by an external PC using Windows®-based operating software.

Features

— Solid or liquid samples up to one gram

— Minimal routine maintenance

— Results in three minutes

How it Works

An encapsulated sample is placed into the loading head of the FP-528, where it is sealed and purged of any atmospheric gases that haue entered during sampling loading. The sample is then dropped into a hot furnace and flushed with pure Oxygen for very rapid combustion.

By-products of combustion—CO 2 , H 2 0, N0 x , and N 2 —pass through the furnace filter and thermoelectric cooler for subsequent collection in a ballast apparatus. These collected gases in the ballast are mixed, and a Small aliquot dose is then used for further conversion of the gases. The remaining aliquot that has been reduced is measured by the thermal conductivity cell for Nitrogen.

The System is controlled by an external PC using Windows'-based operating Software.

Specifications

Instrument Range @ 250 mg

  3 cc Aliquot Loop:                  160 ppm or 0.016% to 100% or 0.04 to 300 mg absolute

                                               Nitrogen

Precision @ 250 mg

  3 cc Aliquot Loop:                  80 ppm or 0.5% RSD, whichever is greater

Readability                             0.001%

Calibration                             Standard Sample; Linear

Analysis Time                        3 minutes nominal

Sample Size                           Up to 250 mg

Detection Method                 Thermal Conductivity

Chemical Reagents              Anhydrous Magnesium Perchlorate, Calcium Oxide, Sodium Hydroxide an an inert base, Copper Sticks, N Catolyst Reagent, Copper Turnings, Alumina Pellets, Magnesium Oxide

Gas Required

  Carrier Gas:                          99.99% Helium or Argon 40 ±4 psi (2.76 bars)

  Combustion Gas:                  99.99% Oxygen

                                               40 ±4 psi (2.76 bars)

  Pneumatic Gas:                    Compressed Air, source raust be oil and water free. 40 ±4 psi (2.76 bars)

Gas Flow Rates

  Carrier Gas:                          Analysis: 200 mL/min (measure), 30 mL/min (reference) Conservation: 30 mL/min (measure), 30 mL/min (reference)

  Combustion Gas:                  1.3 to 6 L/min

                                               (user programmable Oxygen profile)

Regulators

  Helium:                                  0 to 125 psi, CGA 580,

                                               15/16-14 Female R.H.

  Oxygen:                                 0 to 125 psi, CGA 540,

                                               7/8-14 Male R.H.

Air:                                           0 to 125 psi, CGA 346,

                                               13/16-14 Male R.H.

Furnace Range                     Up to 975° Celsius

Weight

  Determinator:                        150 lb. (68 kg)

Physical Dimensions

  Determinator:                        28 in. H x 21 in. W x 23 in. D (71 cm x 53 cm x 58 cm)

Electrical Power Requirements

Determinator:                          230 V— (±10%), 50/60 Hz,
10A

Applications

Foods

Feeds

Forages

Fertilizers

Milled Products

Product groep: N/NOX analyzer