TOC

Shimadzu TOC 5050

Speciale prijs € 3.250,50
-25%
Korting
until 31 mei 2024
Normale prijs € 4.334,00
Excl. 19% VAT , excl. Shipping Cost
€ 3.868,10 incl. Vat
Seriennummer: 32055
Status: Stock unit?The device is in our stock, however, has to be inspected by our technician, in order to be able to guarantee complete function.
Verzending: 10-14 werkdageniFor incoming orders until 12:00 (German local time). If customs handling is required, shipment will be delayed.
Beschrijving:
Shimadzu TOC Analyzer TOC 5050.
Met printer OKI Microline 390 elite.
Schuif het bedieningspaneel met numeriek toetsenblok.
230 V. 50/60 Hz 1200 W.
Toevoegen aan offertelijst
Meer informatie
Objektnummer B00032055
Seriennummer 32055
Object Naam Shimadzu TOC 5050
Status Lagergerät
Fabrikant SHIMADZU
Verzending 10-14 werkdagen

Status, leverings- en betalingsvoorwaarden

Apparatuurcontrole

De gebruikte apparatuur wordt voorafgaand aan levering gecontroleerd door Labexchange Service GmbH. U ontvangt volledig functionerende apparatuur.

 

Verzending

De vermelde verzendtijden zijn telkens de kortste voor een artikel. In bepaalde gevallen kunnen de daadwerkelijke verzendtijden daarvan afwijken. De uiteindelijke verzendtijden worden aangegeven in de opdrachtbevestiging.

In de regel bieden we combinatieleveringen aan. Levertijden zijn afhankelijk van het artikel met de langste levertijd. Deelleveringen zijn mogelijk tegen een toeslag.

 

Verzendmethoden

Koeriersdiensten, transportbedrijven, zelf afhalen, levering door Labexchange wagenpark

 

Informatie levering

De prijzen zijn exclusief verzendkosten. De genoemde verzendkosten zijn de te verwachten kosten. Afwijkingen zijn mogelijk. In het geval geen kosten voor verzending zijn gespecificeerd, vraag die dan afzonderlijk aan.

Voor levering in landen buiten de EU wordt voor export een toeslag van € 70,00 in rekening gebracht. Opmerking: We geven geen preferentieel certificaat/EUR1 af. Bij zelf afhalen/af fabriek (EXW) uit derde landen en de EU wordt 16% btw als borg ingehouden, tot we de ontvangstbevestiging/het leveringscertificaat van de koper hebben ontvangen.

 

Betalingsvoorwaarden

Wij accepteren geen betalingen per creditkaart, Letter of Credit, PayPal etc. Het factuurbedrag is volledig verschuldigd. Er zijn geen betalingskortingen. De goederen blijven tot volledige betaling ons eigendom.

Land

Mogelijke betaalmethoden

Opmerking

Duitsland, Oostenrijk, Zwitserland

Betaling via factuur, vooruitbetaling

Betaling via factuur is mogelijk voor ondernemingsklanten.

Nederland, België en Luxemburg

Betaling via factuur, vooruitbetaling

Betaling via factuur is mogelijk voor ondernemingsklanten.

Andere landen

vooruitbetaling

 

 

Onze Algemene Voorwaarden voor Verkoop, Levering en Betaling zijn hierop van toepassing. Deze voorwaarden zijn hier te downloaden.

Tussenverkoop is ons voorbehouden.

 

Beschrijving status:

Alle artikelen zijn gebruikte artikelen, tenzij bij een artikel uitdrukkelijk wordt vermeld dat het om een nieuw apparaat gaat.

Status

Conditie

Opmerking

Onmiddellijk verkrijgbaar

gebruikt Het artikel is al gecontroleerd en is in perfecte staat. Het kan onmiddellijk aan u worden verstuurd.
Op voorraad

gebruikt

We hebben het artikel in ons magazijn. Onze technici zullen het artikel voorafgaand aan levering controleren. U ontvangt volledig functionerende artikel.

Gepubliceerd

gebruikt

Het artikel is nog bij de aanbieder. Na uw bestelling wordt het door ons aangekocht, gecontroleerd en aan u verstuurd. Een functioneringscertificaat en een servicerapport zijn bij de levering inbegrepen.

Nieuw

nieuw

Dit is een artikel dat nieuw van de fabriek komt. Hiervoor gelden de garantiebepalingen en wettelijke garantietermijn van de fabrikant.

Firma:              Shimadzu

Modell:            TOC 5050

Kommentar:   Dokumente engl.

 

 


Measurement of TC (total carbon)

Pure air carrier gas is flow-regulated to 150mL/min. and allowed to flow through the TC combustion tube which is packed wich catalyst and kept at 680°C. When the sample entern the TC combustion tube, the TC (total carbon) in the sample is oxidized into carbon dioxide. The carrier gas contain­ing the combustion products from the TC combustion tube flows through the IC reaction vessel, dehumidifier, halogen scrubber, and finally reaches the sarnple cell of the nondisper­sive infrared (NDIR) detector, which measures the carbon diox‑

ide content. The Output signal (analog) c :ff , the NDIR detector is

displayed as peaks. The peak areas are measured and proces­sed by the data processing unit.

Since the peak areas are proportional to the total carbon concentrations, the total carbon in a sample can be easily determined from the calibration curve prepared using Standard solutions of known carbon content.

Total carbon is the sum of the TOC (total organic carbon) and the IC (inorganic carbon)

 

Measurement of IC (inorganic carbon)

The sample is injected into the IC reaction vessel which has carrier gas bubbling through the IC reaction solution. Only the inorganic carbon in the sample is converted into carbon doxide, which is then detected by the NDIR detector.

The concentration of inorganic carbon is the sum of carbon­ate and hydrogen carbonate.

 

Measurement of TOC (total organic carbon)

The TOC concentration is obtained by subtracting the IC concentration from the TC concentration.

 

Measurement of NPOC (non-purgeable organic carbon)

An acidified sample is sparged with.high purity air to remove the IC; then the TOC content is measured directly. The result is generally called TOC, out fiere it is specifically caIed NPOC (non-purgeable organic carbon) to distinguish it from the TOC value obtained from the differente between TC and IC. The Spargrog process will remove both IC and those organic carbon cornpounds that are volatile at ambient temperatures.

 

 


Specifications

Analyte

TC, IC, TOC (TC-IC), NPOC (non-purgeable organic carbon)

Method

Combustion/non-dispersive infrared gas analysis method 

Combustion temperature

680° C 

Measuring range

50ppb to 4000ppm (to 5000ppm for IC)

Average analysis time

2 to 3 minutes for both TC and IC (4.5 minutes for TC and 3.5 min. for IC at the longest) 

Repeatability

Standard deviation is less than 1% of full scale for the range less than 2000ppm (less than 2500ppm for IC), and less than 2% for full scale for the range from 2000ppm to 4000ppm (from 2500ppm to 5000ppm for IC).

Sample introduction

Automatic injection

Sample injection volume

4 to 250 µ L

Pretreatment for IC

Automatic sparging function 

Carrier gas

Cylinder of high-purity air, about 600kgf/cm 2 (7kgf/cm 2 max.) in supply pressure; 150 mL/min. in flow rate (300mL/min. including sparging) 

Data processing

.

.

Detector signal 

Linearization, baseline correction, peak detection, and area calculation 

.

Data 

Calculation of calibration curve concentration using unlimited number of points (one to four points for stand-alone mode); automatic selection of best calibration curve; store an unlimited number of calibration curves; automatic exclusion of anomalous value(s) and automatic re-analysis/re-calculation; calculation of standard deviation and coefficient of variation, automatic re-analysis with different measurement range and/or different sample volume when response goes off scale. 

.

Instrument control 

Aspiration, measurement, and injection of sample; TC furnace temperature; ON/OFF of carrier gas and sparge gas. 

.

Other features 

Automatic selection of the optimum set of operation conditions; maintenance/self-diagnostics, warning of abnormality; timer for restarting from the running mode. 

Display

White liquid crystal display with back-light, 640x400 dots, 88 characters x 22 lines.

Printer

Thermal, 240-dot graphic printer, 40 characters/line, 110 mm in chart width.

Ambient temperature requirements

5° to 35° C 

Power requirements

100, 110, 115, 120, 127, 220, 230, or 240V as ordered, ±10%, 50/60Hz, about 300 VA power consumption . (500VA max.) 

Approx. dimensions and weight

480 W X 525 D X 480 H mm (excluding projections), 46 kg 

Optional equipment: SSM-5000A solid sample module

 

 

The system is complete with the solid sample modale SSM-5000A.

·    switch between aqueous and solid samples without further instrument conversions

·    large sample size of up to 1 g

·    separate TC determination (total carbon) and IC (inorganic carbon) enable the exact determination of the TOC contents

·    high sensitivity enables its use in cleaning validation using the glass fibre swab method without the need for extraction

 

Product groep: TOC

Back to Top