Archivio

Xiril X75-1-2

Seriennummer: 014037
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00014037
Seriennummer 014037
Nome oggetto Xiril X75-1-2
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   Xiril

Modell:                X75-1-2

Kommentar:        Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

Xiril 75 - An ideal liquid handling robotic workstation for the entry­level market or small sample numbers with an outstanding performance/price ratio.

Pipetting, plate handling, barcode reading and shaking etc. are built onto a small footprint to make the Xiril 75 ideal for automated reformatting, archiving, compound dissolution, hit picking and normalisation.

Applications

DNA Isolation

RNA Isolation

PCR Setup

FTA Technology

General Liquid Handling

ELISA Preparation

Hit Picking

Replication

Reformatting

Serial Dilution

INSTRUMENT CONFIGURATION

Instrument Specs                    Xiril 75

Outer Dimensions:                  length   x: 76 cm (30")

                                               depth    y: 52 cm (20")

                                               height   z: 66 cm (26")

                                               weight w: 41 kg (90 lbs)

Working Dimensions:             length   x: 55 cm (22")

                                               depth    y: 25 cm (10")

                                               height   z: 11.5 cm (4.5")

Deck Capacity                         12 microplate positions

Arms                                        1 or 2 arms

Channels per Arm                   1 or 2 channels

Instrument Power                    280 VA

Software

Software, Operating System Lirix Software Package, Wind OWS TM XP, Service Pack 2 ,

Computer & Communication

Computer        - Embedded in pipetting deck, data access via USB 2.0 port in support stand
- Technical data: CeleronM 1.5GHz, 512 MB RAM, 40 GB HD

                        - Communication: 2 serial ports RS-232, 4 USB 2.0 ports, 1 parallel port, LAN

                           (RJ-45)

Communication High speed CAN bus; max speed of 1 MBit/sec; 2-6 CAN ports in support

Robotic Performance

Position Accuracy                   in X/Y/Z: +/- 0.2 mm

Plate Handler "Plate-GripX"     Lifts objects up to 400 g (0.9 lbs)

Pipetting Performance

Liquid Detection with Pressure        Single or multiple detection, independent for each channel

Sensor                                              Liquid level detection and clot detection

Tip Types                                          Disposable tips with and without filters; channels with

                                                         indipendent Y and Z movement

Pump Sizes                 Medium pumps: 250 µl                        Large pumps:       1000 µl

Volume Ranges           Medium tips:         2-250 µl                     Large tips:             10-1000 µl

Precision + Accuracy                             Pump Size                Volume dispensed   Precision (CV%)        Inaccuracy (%)

                                    250 µl                    20 µl                          1.0%                         2.5

                                                                200 µl                        0.5%                         1.0

                                    1,000 µl                 100 µl                        1.0%                         3.0

                                                                1,000 µl                     0.5%                         1.0

Pipetting Techniques

Container Format        Lirix supports all liquid container formats up to 384-well plates

Pipetting Skills             - Single pipetting, multi pipetting, parallel pipetting, aliquoting, archiving Serial dilutions, pre-dilutions, multiple common pre-dilutions - Liquid mixing in source and destination container

Optional Devices

Plate Handler "Plate-               Gripper fingern are manipulated with two tip adapters

GripX"

Barcode Scanner "Tube-       Most common barcode typen (e.g. Code 39, Interleaved 2 of 5

ScanX"                                    Codabar, Code 128, etc.)

Plate Shaker "Plate-                Linear and orbital shaking mode with Speed range 100-2'000

ShakeX”                                   rpm and an amplitude of 2 mm

Heating/Cooling Devices        Temperature control devices for microplates, tubes and customized racks and Containers.

SPE Vacuum Station              Vacuum-based solid phase extraction device for NA and protein isolation.

Magnetic Bead Station            Magnetic bead Separation for NA and protein isolation.

Power Supply Input

Voltage, Frequency, Power    Embedded in pipetting deck; 110/230 VAC; 50/60 H2

Regulatory

Standards        In compliance with CE Standards (bears the CE mark)

Environmental Conditions

Temperature    Operating: 15-32°C (59-90°F); Storage: -15-70°C (5-158°F)

Relative Humidity        Operating and storage: 30-80 % rH (non-condensing) at 30°C (86°F)