Archivio

WTW LF 530

Seriennummer: 017102
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00017102
Seriennummer 017102
Nome oggetto WTW LF 530
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Company:      WTW

Model:             LF 530

 

 

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

 

 

 

Technical specifications

 

 

 

Modes

Conductivity Ϟ (with cell constant regulator)

Temperature ° C

 

 

Measuring ranges

 

Conductivity Ϟ:

 

  • With constant adjustment K = 0.1cm -1 0-199.9 Ä©S / cm0-19.99 mS / cm  
    • 0-1999 mS / cm
    • 0-19.99 s / cm
  • With constant adjustment K = 1.0 cm -1 0-1999 Ä©S / cm0-199.9 mS / cm
    • 0-19.99 mS / cm
    • 0-199.9 s / cm
  • With constant control K = 10 cm -1 0-19.99 mS / cm0-1999 mS / cm
    • 0-199.9 mS / cm
    • 0-1999 mS / cm

 

Each fixed-point representation

 

Temperature: 0 - 100.0 ° C

 

 

Measurement inaccuracy

Ϟ: ± 0.5% of reading ± 2 digits

° C: better 00:25 K

 

 

Constant setting

0.1 / 1/10 cm -1 ± 25% with 0.1% resolution

 

 

Measuring frequency

4 kHz, a frequency technology with automatic compensation of capacitive reactive currents

 

 

Temperature compensation

0-50 ° C manually or 0-100 ° C automatically via temperature sensors

Reference temperature 25 ° C (20 ° C on request possible, internally switchable)

Temperature coefficient adjustable 0-4% / K (° C)

 

 

Ambient temperature

0 - 50 ° C

 

Temperature effect

<0.2% per 10 K

 

Recorder output

Ϟ: 0 - 2 V per measuring range

° C: 10 mV / K ≙ 0 - 1, V

 

 

Printer output (option)

BCD parallel

 

 

Electrode terminal

Two 4mm sockets, rear panel

 

 

Platinier port

Two 4mm sockets, rear panel

 

 

Platinization power

6 mA

 

 

Protection class

I (protective conductor connection) in accordance with IEC 348 and VDE 0411

 

 

Insulation group

B according to VDE 0110

 

 

Climate class

2 according to VDI / VDE 3540

 

 

Protection

Front panel IP 54

Total unit IP 41 to DIN 40050

 

 

Weight

2.8 kg

 

 

Dimensions

(B) x 250 (H) x 160 (T) 170 mm (a)

(B) x 250 (H) x 185 (T) 205 mm (b)

The system can be operated with a vertical (a) and tilted (b) front panel, the desired setting is obtained by turning the appliance foot by 180 °.

 

 

Supply

220 V, 50/60 Hz, 5 VA

 

Gruppo prodotti: Misuratori Conducibilità