Archivio

WTW A 101

Seriennummer: 013313
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00013313
Seriennummer 013313
Nome oggetto WTW A 101
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              WTW

Modell:            A 101

Kommentar:   Dokumente deut.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Einsatzbereich und Kurzbeschreibung

Der Ammonium Analyzer A 101 AutoClean ist ein Meßgerät zur kontinuierlichen Überwachung der Ammoniumkonzentration in Abwasserbehandlungsanlagen.

Das Analysegerät erfaßt hierbei potentiometrisch über eine ionenselektive Meßkette (pH-Bereich ≥11) die Parameter NH 4 -N und NH 4 .

Für den einwandfreien Betrieb des Ammonium Analyzers ist ein Probenstrom von > 5 mVI erforderlich. Bei Probenahmen im Kläranlagenablauf ist keine zusätzliche Probenaufbereitung erforderlich. Das AutoClean-System des A101 AutoClean gewährleistet problemlosen und wartungsarmen Betrieb. Bei Betrieb im Belebungsbecken ist eine Probenaufbereitung erforderlich.

Das neuartige AutoClean-System gewährleistet einen sehr zuverlässigen Langzeitbetrieb des A 101 AutoClean. Der Wartungsaufwand des A 101 AutoClean ist erheblich reduziert im Vergleich zu herkömmlichen Analysem, die hohe Präzision seiner Meßgenauigkeit über die Lebensdauer der Membran unverändert stabil.

Zwischen dem Analysenteil und Elektronikteil des A 101 AutoClean besteht eine Trennung durch einen Zwischenboden. Beide Baugruppen sind zu einer übersichtlichen und kompakten Einheit zusammengefügt.

Reagenzbehälter und Ammoniumstandards stehen in in einer Kunststoff-Auffangwanne und sind in den untenliegenden Analysenteil integriert.

Somit stellt der Automat A 101 AutoClean eine äußerst kompakte Meßeinrichtung dar.

Reagenzverbrauch: 10 l in 14 Tagen.

Verbrauch Standard A: ca. 1,5 l in 60 Tagen (bei Kalibrierintervall 24h).

Verbrauch Standard B: ca. 1,5 l in 60 Tagen (bei Kalibrierintervall 24h).

Das Gerät verfügt über eine automatische 2-Punkt-Kalibrierung ( AutoCal ).

Die Steuerung des A 101 AutoClean übernimmt ein Mikroprozessor. Außer den Steuer- und Meßfunktionen erledigt er auch noch viele Überwachungsaufgaben und gibt Meldungen aus.

Der Meßwert wird über eine Digitalanzeige dargestellt. Parallel dazu wird der Meßwert an einem Schreiberausgang (0/4 .. 20 mA, galvanisch getrennt) und an einer V24/RS 232 C - Schnittstelle ausgegeben.

Über Schaltkontakte ist auch die direkte Ansteuerung von Peripherie (z.B. Alarmlampen, SPS-Eingänge) möglich.

Diese Kontakte sind für Gerätemeldungen und Grenzwertalarme verwendbar.

Dabei können die Grenzwerte mittels Tastatur nach den jeweiligen Anforderungen eingestellt werden.


Geräteansicht

Technische Daten

mg/I NH 4 -N

mg/I NH 4

µmol/l

NH 4 -N oder NH 4

Meßbereich

  0.1...   1000

0.1 ... 1287

7 ... 71390

Auflösung

    0   .... 100:0.1

100.....1000:    1

0 ...      100:0.1

100   ...1287:   1

1

Meßgenauigkeit                                 ± 5 % vom Meßwert

Meßprinzip                                        Potentiometrische Messung

Meßmethode                                     Gassensitive Meßkette

Ansprechzeiten ab Geräteeingang   T 90 ≤ 3 Minuten

Meßwertintervall                                Alle 5 s

Reagenziendurchsatz                      10 l Reagenz in 14 Tagen

Standardverbrauch                           ca. 1,5 l Standard in 60 Tagen

                                                         (bei Kalibrierintervall 24 h)

Kalibrierung                                       Standards mit 5 und 50 mg/I NH 4 -N

Überwachungsfunktionen                 AutoFlow Control, AutoTherm Control, AutoCal

Meßwertdokumentation                    Schreiber

Druckeranschluß über RS 232 C-Schnittstelle Computeranschluß über RS 232 C- Schnittstelle

Fehlermeldungen                              über Digitalanzeige, Dokumentation auf Drucker oder Computer, Meldekontakt

Anforderungen an die Probe             keine (Betrieb im Kläranlagenablauf) Filtration (Betrieb in Belebung)

Meßguttemperatur                            Thermostatisierung im Thermoblock

Schreiberausgang                            0/4 mA...20 mA, galvanisch getrennt.

                                                         Bürde max. 500 Ω

                                                         Skala einstellbar, linear, log (KA-Tagebuch)

Genauigkeit                                       entsprechend der Meßgenauigkeit

Digitale Ausgänge / Meldekontakte     Wechselschaltkontakte (24 V, 2A) für

                                                         - Messen

                                                         - Störung

                                                         - Kalibrieren

                                                         - Alarm 1

                                                         - Alarm 2

                                                         - Behälter nachfüllen

                                                         - Permeatmangel

                                                         - Hold Meßwert

                                                         7-polige Binderbuchse

Digitale Eingänge                              Kontakt „Neuer Meßwert” zum Start eines neuen Meßvorgangs

Digitale Schnittstelle                         RS 232 C - bidirektional –

                                                         Buchse, 7-polige Binderbuchse

Abmessungen                                  H: 1230 mm, B: 570 mm, Platzbedarf bei geöffneter Türe (Tiefe): 900 mm, T: 380 mm

Gewicht                                             ca. 40 kg ohne Reagenzien

Schutzklasse                                    1 nach IEC 1010

Schutzart                                          IP 54 nach DIN 40050

Isolationsgruppe                               C (VDINDE 3540)

EMV-Störaussendung                      EN 50081-1 und

                                                         FCC Part 15 Subpart B Limit Class A

EMV-Störfestigkeit                            EN 50082-2 und NAMUR-Empfehlung Teil 1

Klimaklasse                                      LYE, DIN 40040 (KI.2 VDINDE 3540)

Umgebungstemperatur                    Lagerung:          -25°C ...+65°C (Gerät trocken)

                                                         Betrieb:              +5°C ... +40°C

Relative Feuchte                               Jahresmittel ≤ 75 %, 30 Tage/Jahr: 95 %

                                                         übrige Tage: 85 %, leichte Betauung: ja

Prüfverfahren                                    DIN IEC 68

Prüfzeichen                                      GS-Zeichen

                                                         CE-Zeichen (Konformitätserklärung) Netzversorgung            200 V/AC..250 V/AC, 5OHz..60 Hz

                                                         100 V/AC..125 V/AC, 5OHz..60Hz (optional)

Stromaufnahme                                max. 0,5 A

Verhalten des Geräts

- bei/nach kurzem Netzausfall (< 10 Sek):    Akkupufferung, Betrieb wird wieder aufge­nommen

längerer Netzausfall (> 2 h)              Betriebsbereitschaft

Schalter                                            Ein/Aus-Schalter

Tasten                                               Folientastatur mit 11 Tasten und taktiler Rückmeldung

Anzeige                                             FIP-Anzeige, 20-stellig, 10 mm hoch

Netz                                                  Binderbuchse Serie 692/693 4-polig

Komponenten des Geräts

Analysenteil

Hardware

•            Reagenz im 10 1 Behälter. Standard A und Standard B jeweils in 1,5 1 Behältern.

•            Probenzufuhr über Uberlaufgefäß.

•            Auswahl der geförderten Chemikalien mittels Magnetventilen M1 und M2.

•            Schlauchpumpe zur kontinuierlichen Förderung von Meßgut (ggf. Standards) und Reagenz. Reagenzdosierung erfolgt über Schlauchdurchmesser und Pumpengeschwindigkeit.

•            Thermoblock

•            Sedimentations Überlaufbehälter

•            AutoClean-System

Software

•            AutoTherm Control: Thermostatisierung von Meßgut und Elektronik um Temperatur­abhängigkeiten zu verhindern.

•            AutoFlow Control: Messung des Druckes im Schlauchsystem zur Erkennung von Verstopfungen, Leckagen, Behälterfüllstände (P1, P2, P3).

•            Steuerung des AutoClean-Systems

Elektronikteil

•            Auswertung und Berechnung der Meßwerte

•            Automatisierung aller Betriebszustände im Analysenteil

•            Benutzerführung über frontseitige Tastatur. Anwenderfreundliche Farbcodierung der Tasten: (gelb: Hauptbetriebsarten, weiß: Editiertasten, grün: Serviceroutinen und Zusatzinformationen, rot: Zweitfunktion für Parametereinstellung)

•            Überwachung des Analysenteils auf Fehler

•            Automatische Störungsbehebung bzw. Ausgabe von Störmeldungen über Display,

Meldekontakte und V24/RS 232C-Schnittstelle.

•            Eigener Gehäuseteil, Schutzart IP 54.

•            20-stellige 14-Segmentanzeige für Klartextmeldungen

•            V24/RS232C-Schnittstelle, bidirektional

•            Alarm-, Steuer-, und Meldekontakte

•            Schreiberausgang 0/4 ... 20 mA, galvanisch getrennt.

•            Femsteuerkontakt "neuer Meßwert"

Gruppo prodotti: Analizzatore Parametri Specifici