Archivio

Watson Marlow 601 S

Seriennummer: 016132
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00016132
Seriennummer 016132
Nome oggetto Watson Marlow 601 S
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Watson Marlow

model :                   601 S

annotation :           Dokumente engl .

 

 

 

 

WATSON‑ MARLOW

601S/R

Variable speed high-flow pump

A local on/off switch is situated on the back of the motor module to isolate this module. It is recommended that this switch be set to the off position before loading tubing into the pumphead or removing the pumphead . This is safer and also makes the loading of the tubing easier. This facility is provided particularly for situations where the motor module is some distance from the controller module. Where possible, mains power should be switched off at the controller module.

Before operating the pump, ensure that the motor module is properly connected to the controller module and that the local isolating switch is in the on position.

The pump can now be operated from the controller module. The power switch allows clockwise or anti-clockwise rotation to be selected. The normal direction of rotation for extended tube life is clockwise. Using anti-clockwise rotation, pressures up to double those obtained with clockwise rotation can be obtained but at the cost of tube life.

Pumphead speed is set on the front panel potentiometer between 10 and 100, and corresponds with rpm.

A current limiting circuit is incorporated in the design to prevent the maximum current rising above an acceptable level. The circuit activates at a pre-determined level to reduce power to the motor, so reducing its speed.

Specification

Nominal maximum rotor speed                                                        100 rpm

Speed control ratio                                                                                 10:1

Operating voltage/frequency                                             90-250V 50/60Hz

Maximum power consumption                                                            200VA

Operating temperature                                                                 OC to 35C

Storage temperature                                                                  -40C to 70C

Relevant standards                                                                   CEEIO, IP44

Motor module dimensions                                              195 x 200 x 325mm

Control module dimensions                                             85 x 200 x 325mm

Motor module weight                                                                            8.1kg

Control module weight                                                                          2.5kg

Pumphead module weight                                                                    2.9kg

Pumphead

The 601R is a spring-loaded twin roller pumphead pre-set in manufact­ure to accept tubing with a nominal wall thickness of 3.2mm. Tubing with bore sizes of between 4.8 and 15.9mm can be used. This setting will meet most requirements, but adjustment of the setting for other wall thicknesses is a simple task.

The pumphead can be oriented to any of four positions to suit indiv­idual requirements. Only two screws are used to secure the track to the front panel. Re-positioning is carried out by removing the screws, rotating the track to the required position and replacing the screws.

Tube loading

WARNING Switch off the pump, both at the controller module and the motor moduZe local isolating switch, before loading the pump­head .

Fully open the hinged guard

Select a length of tubing appropriate to the requirement, noting that a length of 410mm is need for the track system.

      Offer up that part of the tubing to be housed in the pumphead . First ease the tubing into one of the adjustable clamps and then, whilst rotating the rotor clockwise (a tool is provided for this purpose), feed the tube between the rollers and the track. Ensure that the tube lies naturally against the treck and is not twisted or stretched. This is particularly important for the larger tube sizes.

      Locate the other end of the loaded section of the tube into the

second adjustable clamp, ensuring that the tube is not slack or twisted in the    pumphead .

      Clamp the tube firmly by turning the serrated adjustment wheel. Both clamps will grip the tube simultaneously. Ensure that the tool is removed and close the guard.

Adjustment of the rollers

The spring-loaded twin rollers compensate for tolerance variations in the tubing, eliminating the manual adjustment normally required by peristaltic pumps.

The rotor is set in manufacture for 3.2mm wall thickness tubing of most bore sizes. This setting can advantageously be adjusted, how­ever, in certain cases. For instance, where large bore tubing is used and the delivery head is low, tubing life can be further extended by increasing the normal pre-set gap of 5.2mm. Re-adjustment will also be required when tubing is used having a wall thickness other than 3.2mm.

There is an adjustment screw an each of the two roller arms. Correct and equal adjustment is important. Over-occlusion will reduce tube life. Under occlusion will reduce pumping efficiency.

As a general rule, the gap setting for a given tube should be 20% less than twice the wall thickness of the tube.

To adjust the gap setting, turn the adjustment screws: Clockwise for an increase in gap setting or anti-clockwise for a decrease in gap setting. One complete turn of the screw changes the gap setting by approximately 1.0mm.

Should it appear that the roller arms are not equally adjusted, and you want to restore the original factory setting, turn the adjusting screws until both rollers are just in contact with the treck , then tighten each screw by five turns

The flow rates given below were obtained pumping water at 20C with nominal suction and delivery pressures. Where flow rate is critical it should be measured under operating conditions. The major factors affecting flow rate are suction and delivery heads, fluid viscosity, temperature, and tubing material used.

601S/R Flow rates (litre/min)               Minimimum flows 10% of rates given

Tubing internal diameter (mm)

rpm       4.8            6.4            8.0          9.6            12.7            15.9

100      0.90          1.24        1.80          2.40           4.60            6.60

 

Gruppo prodotti: Tubi per Pompe

Non è stato trovato alcun prodotto corrispondente alla selezione.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite