Seriennummer: 42074
Stato: Provider?The device is still with the provider. After your order is processed the device is purchased and checked by us. You get the device completely checked and with the Labexchange® full guarantee and a warranty certificate . The delivery time for this product is usually four to six weeks.
Spedizione: 4-6 weeks
Descrizione:
Vacuubrand Pompa per vuoto a membrana MZ 2C.
Con 2 borracce e un refrigeratore ciascuno.
Anno di costruzione sconosciuto.
Add to Offer list
Maggiori Informazioni
Objektnummer B00042074
Seriennummer 42074
Nome oggetto Vacuubrand MZ 2C
Stato Anbieter
Fabbricante VACUUBRAND
Spedizione 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Firma:                   Vacuubrand

Modell:                MZ2C

Kommentar:        Dokumente deut.

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 

 

 

 

 

 

Technische Daten

 

Max. Saugvermögen 50/60 Hz                       m²/h                 1,7/2,0

(nach DIN 28432)

 

Enddruck (absolut)                                         mbar                9

 

Enddruck (absolut) mit Gasballast                 mbar                20

 

Max. zulässiger Druck am Auslass                bar                   2

(absolut)

 

Max. Druckdifferenz zwischen                       bar                   1,1

Ein- und Auslass

 

Zulässige Umgebungstemperatur bei            °C                    -10 bis +60/+10 bis +40

Lagerung / Betrieb

 

Zulässige relative                                            %                     30 bis 80

Umgebungsluftfeuchte bei Betrieb

(nicht betauend )

 

Max. Strom / Antriebsleistung

100 V~                                                                        A/W                  3,4/180

120 V~                                                                        A/W                  3,0/180

230 V~                                                                        A/W                  1,6/180

400 V~ Mot. EEx e II                                       A/W                  0,59/180

 

Max. Leistungsaufnahme

100 V~                                                                        VA                    340

120 V~                                                                        VA                    360

230 V~                                                                        VA                    370

400 V~ Mot. EEx e II                                       VA                    410

 

Max. zulässiger Bereich                                                       100 V~ +10%/-10% 50/60 Hz

der Versorgungsspannung                                                    120 V~ + 5%/-10% 60 Hz

                                                                                              230 V~ +10%/-10% 50/60Hz

400 V~+5%/-5% 50Hz Mot.EEx eII

 

Nenndrehzahl                                                 min -1                     1500/1800

 

Motorschutz                                                                           thermischer Wicklungsschutz

 

Schutzart nach IEC 529                                                        IP 54

 

Messflächenschalldruckpegel                        dBA                  42

(Abstand lm)

 

Einlass / Auslass                                                                   Schlauchwelle DN 10 NPT 1/8-27

 

Abmessungen über alles L x B x H                mm                  266 x 241 x 170

 

Gewicht betriebsfertig                                     kg                     10,5

 

 

 

 

Komponenten                                   Medienberührte Werkstoffe

---------------------------------------------------------------------------------------------------------------------------

Gehäusedeckelinnenteil                      PTFE kohlenstoffverstärkt

 

Kopfdeckel                                          ETFE

 

Membranspannscheibe                      ETFE

 

Ventil                                                   MZ 2C: FFKM (z. B. Kalrez ® '*)

 

Membrane                                          PTFE-NBR (z. B. Perbunan ® **) Sandwich

 

Einlass/Auslass/Verschraubung        ETFE

 

Schlauch                                            PTFE

 

*   eingetragenes Warnzeichen Du Pont

**eingetragenes Warenzeichen Bayer AG

 

Technische Änderungen vorbehalten!

 

 

 

 

Beim Einbau in ein Vakuumsystem

  • Drosselverluste vermeiden durch kürzest mögliche Vakuumverbindungsleitungen großer Nennweite.
  • Übertragung mechanischer Kräfte durch starre Verbindungsleitungen vermeiden und elastische Schlauchstücke oder Federungskörper zwischenschalten. Achtung: Elastische Elemente können sich beim Evakuieren zusammenziehen.
  • Vorteilhaft: Ventil auf Saugstutzen zum Warmlaufen/Nachlaufen aufbauen.
  • Kondensatrückfluss aus der Auspuffleitung in die Pumpe verhindern, Auspuffleitungen stets fallend verlegen.

 

 

 

Vor Inbetriebnahme

  • Max. Umgebungstemperatur: 40 °C.
  • Beim Einbau in ein Gehäuse oder bei hoher Umgebungstemperatur für gute Belüftung.
  • sorgen. Mindestabstand von 20 cm zwischen Lüftern und angrenzenden Teilen einhalten. Bei einem Aufstellungsort über 1000 m über NN (Gefahr von unzureichender Kühlung) sind Maßnahmen gemäß DIN VDE 0530 zu ergreifen.
  • Bei Stromausfall kann es bei geöffnetem Gasballastventil der Pumpe zu unbeabsichtigtem Belüften kommen. Kann dies zu Gefahren führen, geeignete Sicherheitsvorkehrungen treffen.
  • Drehrichtung des Motors prüfen (nur Drehstrommotoren): Lüfter durch die Lüfterhaube beobachten. Pumpe einige Sekunden einschalten und überprüfen, ob die Drehrichtung des Lüfters mit der angegebenen Drehrichtung übereinstimmt. Falls die Drehrichtung nicht übereinstimmt, sofort abschalten. Händler bzgl. des weiteren Vorgehens kontaktieren.
  • Leckagen bei der Installation zuverlässig verhindern. Nach der Installation Anlage auf Leckagen überprüfen.

 

 

 

Beim Betrieb

Die Pumpe darf nur gegen max. 1 bar Differenzdruck zwischen Einlass und Auslass gestartet werden , da sonst eventuell der Motor blockiert und Schaden nimmt.

  • Höchstzulässigen Druck am Auslass und max. zulässigen Differenzdruck zwischen Einlass und Auslass beachten.

 

Das hohe Verdichtungsverhältnis der Pumpen führt dazu, dass sich am Auslass ein höherer Druck ergeben kann, als die mechanische Stabilität zulässt.

 

Die Pumpe erreicht die angegebenen Werte für Saugvermögen und Enddruck sowie die Dampfverträglichkeit erst bei erreichter Betriebstemperatur (nach ca. 15 Minuten).

  • Kondensation in der Pumpe, sowie Flüssigkeitsschläge und Staub vermeiden, da eine Dauerförderung von Flüssigkeiten oder Staub Membrane und Ventile schädigt.
  • Die Pumpe mit Gasballast betreiben, um die Kondensation von gepumpten Stoffen (Wasserdampf, Lösemittel…) in der Pumpe zu verringern.

 

Ein thermischer Wicklungsschutz schaltet den Motor bei Übertemperatur ab.

  • Achtung: Nur manuelle Rückstellung möglich. Pumpe ausschalten oder Netzstecker ziehen. Vor dem Wiedereinschalten ca. fünf Minuten warten.

 