Archivio

Transgenomic Wave 3500

Seriennummer: 021717
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
Sistema WAVE Transgenomic 3.500. Analisi e separazione di frammenti di acido nucleico. Con 7100 L-pompa Rivelatore L7400. L-7200ACC. L-7300e Senza software.
siehe Storeview
Maggiori Informazioni
Objektnummer B00021717
Seriennummer 021717
Nome oggetto Transgenomic Wave 3500
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Transgenomic

model:                   WAVE

annotation:           Dokumente engl.

 

 

 

 

Hitachi D-7000/D-6000 Interface Module

 

Product Specifications

 

Enclosure

The D-7000 IFM enclosure has the following physical characteristics:

  • Dimensions                 260 mm x 500 mm x 50 mm (W x L x H)
  • Weight                                     6 kg
  • Power Supply             25 VA

 

CPU Board

  • CPU                             68340 (16 MHz)
  • ROM                            256K
  • RAM                             1.0 MB
  • I/O RAM                       256K

 

A/D Converter

  • Analog Range             -10 mV to 1 V
  • Dynamic Range          21 bits
  • Resolution                   0.25 microvolts per count
  • Minimum A/D Speed 12.5 msec.

 

 

 

 

 

Hitachi L-7100 Pump

 

Specifications

 

Pump Unit

 

(1)                Liquid feed system: Dual plunger type reciprocating pump, series connection

 

(2)                Maximum discharge pressure: 39.2 MPa (400 kgf/cm²)

 

(3)                Discharge rate range: 0.001 to 9.999 mL/min

 

(4)                Pressure limit range: 0 to 41.2 MPa

 

(5)                Discharge volume of plunger no. 1: 100 µL/stroke

 

(6)                Flow rate setting accuracy (at constant room temperature of 20°C for distilled water):

  • ±2 µL/min (0.01 to 0.1 mL/min, 1.0 to 39.2 MPa)
  • ±2% (0.101 to 5 mL/min, 1.0 to 39.2 MPa)
  • ±2% (5.001 to 9.999 mL/min, 1.0 to 2.0 MPa)
  • +2% to -1p*% of discharge pressure

(5.001 to 9.999 mL/min, 2.1 to 39.2 MPa)

*p          Pump pressure (MPa)

 

(7)    Flow rate stability: 0.2% RSD or less (retention time at flow rate 1 mL/min, at constant room temperature of 20°C for distilled water)

 

(8)                Compensation of solvent compression ratio and elimination of pulsation:

High-speed feedback real-time control

 

(9)                Pressure display accuracy: ±5%

 

(10)            Constant pressure liquid feed:

2.0 to 39.2 MPa (20 to 400 kgf/cm²) (Flow rate range: 0 to 5 mL/min)

 

(11)            Material of wetted parts:

SUS 316, ruby, sapphire, ceramic, PTFE carbon-impregnated PTFE

 

(12)            Display data:

Parameters

Pump monitor            Flow rate, pressure

Gradient monitor         Elapsed time, mixing ratio, flow rate,

pressure, timer value, etc.

 

(13)            Pump control mode:

  • Single-liquid delivery mode
  • Low pressure gradient mode
  • High pressure gradient mode

 

(14)            Contact input/output terminals:

Event timer: 4 channels

 

(15)            External communication:

D-line

(a) D-line communication mode ( D-line ON )

(b) D-line contact mode (D-line OFF)

OUTPUT PUSY/READY

INPUT             1) GRADIENT START

2) EMERGENCY STOP

 

(16)            Specification of pressure unit: MPa, kgf/cm², bar, psi

 

(17)            Pressure zero adjustment:

Possible

 

(18)            Ambient temperature:

4 to 35°C (condensation unallowable)

 

(19)            Humidity:

45 to 85% RH

 

(20)            Power supply:

100 to 240 V AC ± 10%

 

(21)            Power frequency:

50/60 Hz

 

(22)            Power consumption:

About 100 VA

 

(23)            Dimensions:

260 (W) x 500 (D) x 150 (H) mm

 

(24)            Weight:

About 14 kg

 

(25)            Installation Category:

II (by IEC1010-1 Annex J)

 

 

 

Low Pressure Gradient System

 

(1)                Number of mobile phase

UP to 4

 

(2)                Mixing  

Valve opening/closing time control

 

(3)                Mixing ratio range

0 to 100% (in increments of 1%)

 

(4)                Flow rate setting range

0.001 to 9.999 mL/min (in increments of 0.001 mL/min)

 

(5)                Recommended flow rate range

0.1 to 9.999 mL/min

(If the flow rate exceeds 2.0 mL/min, it is recommended to use the optional mixer.)

 

(6)                Gradient elution profile

Linear/multi-step

 

(7)                Number of programming steps

92 steps max. per program

100 steps max./9 programs

 

(8)                Programming time

Up to 600 min (in increments of 0.1 min)

 

(9)                Programming items

§          B/C/D mixing ratio

§          Flow rate

§          Event Signal output

§          Pump stop, buzzer

 

(10)            Number of programs

9

 

 

 

High Pressure Gradient System

 

(1)                Number of mobile phase

Up to 3

 

(2)                Mixing

Double or triple pump flow rate control

 

(3)                Mixing ratio range

0.0 to 100.0% (in increments   of 0.1%)

 

(4)                Flow rate setting range

0.001 to 9.999 mL/min (in increments of 0.001 mL/min)

 

(5)                Recommended flow rate range

0.1 to 9.999 mL/min

 

(6)                Gradient elution profile

Linear/multi-step

 

(7)                Number of programming steps

92 steps max. per program

100 steps max./9 programs

 

(8)                Programming time

Up to 600 min (in increments of 0.1 min)

 

(9)                Programming items

§          B/C mixing ratio

§          Flow rate

§          Event Signal output

§          Pump stop, buzzer

 

(10)            Number of programs

9

 

 

 

 

 

Dynamic Mixer (Option)

 

Outline

This mixer is used to enhance the mixing accuracy of two or more mobile phases through forcible stirring and thereby stabilize the baseline.

It is combined with a high pressure gradient system or low pressure gradient system. Refer to section 3-7-2 for usage of the low pressure gradient system.

 

Specifications of Dynamic Mixer

 

(1)                Stirring method

With stirrer

 

(2)                Chamber capacity

About 2.0 mL (0.69 mL x 1, 0.65 mL x 2)

 

(3)                Rotational speed

300 rpm (fixed)

 

(4)                Withstand pressure

34 MPa (350 kg/cm²)

 

(5)                Maximum working flow

9.999 mL/min

 

(6)                Recommended working flow range

0.1 to 9.999 mL/min

 

(7)                Rating

12 V DC, 0.5 A

 

(8)                Dimensions

65(W) x 42(D) x 93(H) mm

 

 

 

 

 

Merck Solvent Degasser L-7612

Conforms to EC Low Voltage Standard 73/23/EC

 

Technical Data

 

(1)                Voltage

220 Volt/50 Hz

 

(2)                Tolerable voltage range

±10%

 

(3)                Power consumption

50 watts

 

(4)                Material in contact with liquid

Teflon, PEEK and tefzel (fitting/ferrule)

 

(5)                Degassing channels

4

 

(6)                Optimal flow

0.1 - 3.0 ml/min. per channel

 

(7)                Dead volume per channel

8 ml (+/- 10%)

 

(8)                Membrane surface area

approx. 250 cm²

 

(9)                Liquid connections

1/4-28"

 

(10)            Weight

3.8 kg

 

(11)            Dimensions

160 (h) x 80 (w) x 320 (d) mm

 

 

 

 

 

 

 

 

 

 

 

 

Gruppo prodotti: Life Science / Biotecnologie

Non è stato trovato alcun prodotto corrispondente alla selezione.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure