Teledyne Ultra Trace 3000

Teledyne Ultra Trace 3000
4.800,00 €
Excl. tasse
5.568,00 € incl. tasse

ID-Nr: 33683

Stato: Fornitore  

Spedizione: 4-6 weeksi

Descrizione:
Teledyne Analizzatore di ossigeno analitico Ultra Trace 3000.
Strumento versatile per il rilevamento basato su microprocessore
la percentuale di ossigeno nell'intervallo ppm in una serie di gas di trasporto.
3 campi di misura regolabili: 0-250 ppm, da 0-1 ppm a 0-1000 ppm.
Con trasmettitore di umidità AMT-LD, punto di rugiada da -120 ° a + 20 ° C.
Camera di campionamento con raccordi da 6 mm.
or
Additional Information

Additional Information

Seriennummer 33683
Nome oggetto Teledyne Ultra Trace 3000
Tipo di immobi Gas-Analyse/Gas-Messung
______
Stato Fornitore
Fabbricante Teledyne
Spedizione4-6 weeks
Altri Prodotti

Gruppo prodotti: Analizzatori-Misuratori di Gas

Status, terms of delivery and payment

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by own fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 19% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Technical Specifications

 

manufacturer:      Teledyne

model:                  Ultra Trace 3000

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

Specifications

 

Ranges:                          3 user-configurable ranges

Default ranges:               0-250 ppb, 0-1 ppm, 0-10 ppm O2

Fixed over range:            0-1000 ppm O2 Accuracy: ±5 ppb O2

Sensitivity:                       0.5% of FS at 250 ppb FS (1.25 ppb)

Response time:               90% of FS at 77°F (25°C)

                                        PPB range – programmable from 2 minutes to 1 hour

                                        < 30 seconds for 0-10 ppm or higher ranges < 50 seconds for 0-1 ppm range

Operating temp:               59 to 95°F (15 to 35°C)

                                         For highest accuracy and stability, operate at fixed ambient temp.

Signal output:                   0-1 VDC percent of range; 4- 20 mADC isolated percent of range

Range ID contacts:           Form A normally open contacts, 3A resistive (quantity 4)

Analysis display:               5 digit red LED, 3/5" high numerals

Menu display:                   20 character, 2 line vacuum fluorescent

Digital output / input:         Bi-directional RS-232C serial interface, (ModBus RTU optional, contact factory)

Power requirements:         Universal AC input ranges, 85 to 250 VAC, 47 - 63 Hz

Sensor:                              Micro-fuel Cell, Class B-2CXL

Sample gas inlet pressure: Min. 1 psig

Sample system:                 All wetted parts, 316 stainless steel

Sample connections:         1/4” VCR male

Mounting:                           Flush panel mount

Dimensions:                       Case: 8.7" W x 7.1" H x 12.7" D (221mm x 180mm x 322.6mm)

Front panel:                       10.79" W x 7.46" H (274mm x 189mm)