Archivio

Tecan Sunrise RC

Seriennummer: 013183
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00013183
Seriennummer 013183
Nome oggetto Tecan Sunrise RC
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Tecan

Modell:            Sunrise RC

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.



SUNRISE general speciticatioins

Optical system                        12 measurement channnels

                                               1 reference channel

Wavelength range                   340 to 750 nm

Wavelength selection              Interference filters (slide of 4 to 6 filters)

                                               Bandwidth: 10nm

Measurement range                340 to 399 nm: 0 to 3.0 OD

                                               400 to 750 nm: 0 to 4.0 OD

Measurement time                  - Single wavelength:    6 seconds

                                               - Dual wavelength:      8 seconds

                                               - Kinetic repeat time:   5 seconds

Accuracy                                 0.0 to 2.0 OD/492 nm: better than +/- 1% +/-0.010 OD

                                               2.0 to 3.0 OD/492 nm: better than +/- 1.5% +/-0.010 OD

Linearity                                   340 to 399 nm:            0.0 to 2.0 OD better- than +/- 2%

                                               400 to 750 nm:            0.0 to 2.0 OD better than +/- 1%

                                                                                  2.0 to 3.0 OD bettcr than +/- 1.5%

Precision                                 0.0 to 2.0 OD/492 nm: better than +/- 0.5% +/-0,005 OD

                                               2.0 to 3.0 OD/492 nm: better than +/- 1.0% +/-0.005 OD

Resolution                               0.001 OD

Interface                                  RS 232 C (remote control)

            Parallel Centronics (printer interface only wlth Option touchscreen)

Shaking                                   Linear shaking in 4 different modes

Physical data                           Width               28.5 cm

                                               Depth               34.0 cm

                                               Height              14,5 cm / 21.0 cm with TS C

Weight                                                min 6.2 kg Sunrise RC; max. 8,6 kg incl. all options

Sunrise absorbance reader: the tailor-made microplate reader suitable for diagnostic, pharmaceutical as well as research laboratories

Sunrise is a versatile microplate absorbance reader providing all the features needed for the numerous applications required in clinical diagnostics, biotechnology and the pharmaceutical industry. The sophisticated design with a 12-channel optical module guarantees high quality and excellent optical performance with fast, reproducible and accurate measurements. Options such as temperature control, different filter slides and a barcode scanner can be added to create a fully customized instrument configuration. Through a new touchscreen option, Sunrise can operate without a PC, saving space and adding a new dimension to ease-of-use and computer-independent data processing. The preferred language can be selected easily.

§                  Absorbance measurement of 96-well microplates

§                  Most comfortable onboard operation with TouchScreen Color

§                  Measurement with high precision and high resolution

§                  4 filter, 6 filter or free wavelength selection filter slide

§                  Fast measurement time: 6 seconds per microplate

§                  Precise temperature control up to 42°C

§                  12 measurement channels and 1 reference channel

§                  Compact and space-saving design

§                  Easy integration in robotic systems

§                  Designed to meet the Directive 98/79/EC for in vitro diagnostics

§                  Magellan™ software for comprehensive data reduction

§                  QC Pac™ tools for absorbance reader qualification guidances and checklists for   instrument qualification (IQOQ package)