Sterrad Sterrad 50
| Objektnummer | B00010406 |
|---|---|
| Seriennummer | 010406 |
| Nome oggetto | Sterrad Sterrad 50 |
| Stato | Archived Product |
Gruppo prodotti: Autoclavi
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The STERRAD 50 System prevents sterilization from taking a big bite out of your budget. Based on the patented application of hydrogen peroxide gas plasma technology , the system is both fast and effective for heat-stable, heat-sensitive, and moisture-sensitive instruments and medical devices. Whats more, the gentle process offers unsurpassed material compatibility and uncompromising safety. The STERRAD 50 System cuts sterilization costs 6 ways:
Increased speed and capacity
· Rapid 45-minute cycle time.
· 1.55 cubic foot rectangular chamber holds multiple trays.
· Dry, low-temperature process means instruments are available for immediate use or storage.
· Reduces expensive instrument inventories.
Unsurpassed material compatibility
· Compatible with most medical devices.
· Tested by 250 device manufacturers on over 1,500 devices.
· The industrys most versatile terminal sterilizer.
Reduced instrument damage and repairs
· Gentler than steam and peracetic acid processes.
· No corrosion due to humidity.
· Reduced damage due to heat, shock, and handling.
Easy to install and move
· No water source, heat booster, or ventilation required.
· Runs on standard 110-VAC to 120-VAC, 60-Hz electrical.
· Compact and portable.
Simple to learn and operate
· Intuitive touch-pad controls.
· Easy-to-follow prompts and instructions.
· Immediate diagnosis and warning of problems.
Safe for patients and the environment
· By-products are oxygen and water vapor.
· No odors or hazardous emissions.
· Achieves 10 -6 SAL (Sterility Assurance Level) of packaged and unpackaged instruments.
Specifications *
Total cycle time: 45 minutes
Cycle temperature: 40°C to 55°C (104°F to 131°F)
External dimensions:
644 mm (25 in) wide
1450 mm (58 in) high (with cart)
827 mm (32 in) deep
Weight:
Sterilizer230 kg (500 lbs)
Cart45kg (100 lbs)
Sterilization chamber:
Rectangular configuration 44 L (1.55 ft 3 ) usable volume
Shelf dimensions620 mm x 400 mm (24 in x 16 in)
Chamber height178 mm (7 in)