Starrsed MU
Objektnummer | B00014401 |
---|---|
Seriennummer | 014401 |
Nome oggetto | Starrsed MU |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Starrsed
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
INSTRUMENT DESCRIPTION
The machine consists of the following:
- The basic unit wich rotating carriage (carousel), 120 glass Westergren pipettes, filling unit, measuring unit, rinsing unit and bar-code reader (optional).
- Vacuum pump.
- Printer stand.
Technical specification
basic unit:
Mains voltage 205-245 V
50/60 Hz
Power consumption Standby 60 VA
Maximum 120 VA
Fuse (20 x 5 mm) Slow blow 1 A
Dimensions Width 620 mm
Height 650 mm
Depth 580 rrm
Weight 56 kg
Minimum table size Width 1500 mm
Depth 750 mm
Vacuum pump;
Mains voltage 205-245 V
50/60 Hz
Power consumption Standby 50 VA
Maximum 800 VA
Fuses (20 x 5mm) Slow blow
Vacuum unit 10 A
Peristaltic pump 1 A
Dimensions Width 345 mm
Height 400 mm
Depth 650 mm
Capacity 13 m 3 /hour
Normal pressure 500 mBar
Noise at 1 mater <54 dB
Total weight 55 kg
Negligible running costs
StaRRsed is a fully automated Erythrocyte Sedimentation Rate analyser operating according to the Westergren method. Because the glass Westergren tubes are washed and dried after use there are no disposables hence very low running costs. StaRRsed is not to be confused with a growing number of ESR readers on the market which still require expensive citrated blood tubes and are thus costly to run.
Totally automated E.S.R.
StaRRsed accepts most makes of closed blood collection tubes with pierceable caps which ensure safety for the operator. Sample identification is either entered via the keyboard or bar code reader and results are printed out exactly 1 hour later on an adjacent printer and/or the Hospital/Lab Computer via the RS232 interface.
Wide Choice
There are three versions of StaRRsed available.
StaRRsed I which accepts citrated blood samples is the most basic.
StaRRsed II has a built in citrate dilution system and accepts EDTA blood samples, thereby eliminating the need (and expense) of a separate citrated blood collection tube, only 1,6 ml. of blood is needed and the rest of the sample is not contaminated in any way and is thus available for a cell count and for making a blood film. StaRRsed III has the saure features as StaRRsed II plus the inclusion of a 30 position Autoloader which improves the "walk-away" feature still further.
The Autolaoder also takes care of mixing the blood before each aspiration. StaRRsed III takes about 10 minutes to load 30 samples at which time the loading cassettes can be changed for the next 30 samples.
Abnormal samples reported
All StaRRseds incorporate temperature correction, that is they measure the actual ESR and calculate a temperature corrected result for 18 degrees Centigrade which can make quite a difference in the summer (high room temperature). They all have the ability to measure and record haziness above the red cell interface in a totally reproducible and objective way and they all include a saline back flush system for the blood sampling line thereby eliminating cross contamination.
StaRRsed features
Carousel holds 120 precision bore glass Westergren tubes. Sample ID via keyboard or bar code labels. Double needle for sampling blood, sampling line backflushed with sahne.
lt takes only 15 seconds to introduce a sample.
ESR automatically measured after 1 hour.
Throughput 100 samples in 1.5 hours.
Westergren tubes emptied, washed and dried with warm air for re-use automatically.
Print out of measured and temperature corrected ESR together with sample ID and sample abnormality if no clear interface detected.
Output to computer via RS232C interface.
Additional feature StaRRsed II
Automatic dilution of EDTA blood with Citrate solution in ratio of 4:1.
Additional feature StaRRsed III
30 position Autoloader (Two racks provided).
Takes 10 minutes to transfer samples to StaRRsed with mixing in between.
Microbiologically safe
All StaRRseds are provided with a large but quiet vacuum pump and waste disposal system which sits below the bench. All liquid waste is separated and pumped off into a 10 I. holding bottle containing bleach for disposal and the entire system is protected with microbiological filters.
Independent evaluation
An independent evaluation carried out on behalf of the Department of Health in the UK (MDD/92/02) concludes that StaRRsed II will pay for itself over 3 years at a throughput of only 60 ESRs a day. StaRRsed I will suit Laboratories with a lower throughput and StaRRsed III will appeal to larger Laboratories.