Spark Holland Mistral
| Objektnummer | B00009503 |
|---|---|
| Seriennummer | 009503 |
| Nome oggetto | Spark Holland Mistral |
| Stato | Archived Product |
Gruppo prodotti: HPLC-Miscellaneous
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
INTRODUCTION
If you work with any HPLC system, an excellent, stable and safe column thermostat is a must for excellent, reproducible results.
A temperature controlled column area contributes to the reproducibility of retention times, columns are more stable at constant temperature and some types of columns are more efficient at elevated temperature, i.e. reverse phase and ionic exchange columns. With a temperature controlled column area room temperature changes will no longer affect your analyzes.
The MISTRAL is the column thermostat that provides exact and reproducible temperature control. Large area heating plates guarantee a safe and stable operation at a temperature range from ambient + 5°C up to 90°C, while forced air circulation ensures excellent temperature uniformity in the column area.
With the optional peltier cooling the MISTRAL ® allows a temperature range from 5°C up to 90°C and temperature changes are achieved in shorter time.
An injector is mounted inside the oven to achieve a maximum temperature stability of the HPLC System.
With the MISTRAL it is possible to program temperature gradients to optimize analyzes.
The MISTRAL ® column thermostat is compatible with most HPLC instruments. It has a remote I/O connector for communication with other HPLC components.

1 Display (adjustable for horizontal and vertical use of the MISTRAL)
2 Keyboard (adjustable for horizontal and vertical use of the MISTRAL)
3 Injection valve
4 Oven door
5 Waste tubing
6 Mains switch
7 Fuses and mains voltage selector
8 Ventilation holes (outlet)
9 Remote I/O connector
SPECIFICATIONS
TEMPERATURE CONTROL
Temperature range: +5°C up to 90°C, MISTRAL® with cool option.*
ambient + 5°C up to 90°C, MISTRAL® without cool option.
Note*: The ambient temperature and humidity directly influences the lower temperature limit of MISTRAL ® . When the temperature and/or the humidity raises, the lower temperature will also raise. Typically a D T of 18°C is possible.
Temperature accuracy: better than 0.1 °C, measured at 30°C in centre of compartment.
Temperature stability: better than 0.1°C, measured at 30°C in centre of compartment.
Temperature reproducibility: better than 0.1°C, measured in centre of compartment.
Temperature gradient: better than 0.2°C, measured in column area at 30°C.
Temperature change MISTRAL® with cool option:
Up: 10°C/min up (with cool option)
Down: 3°C/min down from 70°C to 30°C. (with cool option)
SAFETY
Detection: Vapoursensor with selectable alarm setting
Limiter: Temperature limit switch at 125°C
Electronics: Watchdog circuit for microprocessor check
ELECTRICAL
Electronics: 68000 microprocessor system
Communication: RS232 with Sparklink communication (optional)
Outputs: Relay alarm output temperature or vapoursensor
Relay oven ready
Buzzer alarm temperature or sensor
TTL inputs: Start time base
Emergency shut down
Power requirements: 220 Vac ± 10%, 50 Hz
110 Vac ± 10%, 60 Hz
Power consumption: 400 VA max.
DIMENSIONS (in vertical position)
Dimensions (H x W x D) 514 x 170 x 325 mm usable in horizontal or vertical position
Oven dimensions (H x W x D) 400 x 110 x 50 mm
Weight: 16 kg
DISPLAY
Displayed parameters: Actual temperature in 0.1°C.
Setpoint temperature in 1°C.
Elapsed time in hours and minutes.
OPERATION
Temperature: Temperature selectable in 1°C increments
Time: Time base, 9h59 total time with 1 minute increments.
5 time events available with different setpoints.
Safety: Alarm limit vapoursensor.
Memory: Battery back up memory for programmed parameters.