Siemens Oxymat 5E

Seriennummer: 018271
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
Siemens Gasanalyzer Oxymat 5E.
siehe Storeview
Maggiori Informazioni
Objektnummer B00018271
Seriennummer 018271
Nome oggetto Siemens Oxymat 5E
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   Siemens

Modell:                Oxymat 5E

Kommentar:        Dokumente deut.

 

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

 

Anwendungsbereich

Der OXYMAT 5 dient zur Messung des Sauerstoffgehaltes von Gasen. Die Sauerstoffmes­sung beruht auf dem paramagnetischen Wechseldruckprinzip.

Aufgrund der Selektivität des Meßverfahrens und hoher Korrosionsfestigkeit des Geräts ge­genüber dem Meßgas ergeben sich kaum Anwendungseinschränkungen_

 

Charakteristische Meßeigenschaften des OXYMAT 5:

·          Kurze Ansprechzeit

·          Keine Lageabhängigkeit

·          Meßergebnis unabhängig von Wärmeleitfähigkeit, spezifischer Wärme und Viskosität des Meßgases

·          Meßbereiche mit unterdrücktem Nullpunkt und hoher Genauigkeit

·          Langzeitdrift vernachlässigbar klein

·          Hohe Korrosionsfestigkeit der meßgasführenden Teile

·          Hohe Selektivität

 

Geräteausführung

7MB1010         OXYMAT 5F (Feldgerät)

7MB1020         OXYMAT SE (Einschubgerät)

7M81030          OXYMAT 5F, TÜV-eignungsgeprüft

7MI31040         OXYMAT 5E; TÜV-eignungsgeprüft

1

 

Aufbau

OXYMAT 5F

Das Gehäuse ist unterteilt in zwei getrennte, gasdichte Räume fur Analysierteil und Aus­werteelektronik. Diese Räume sind bespülbar. Die Bedienung erfolgt über eine an der Tür montierte, wasserdichte Folientastatur.

Gasanschlüsse und elektrische Anschlüsse befinden sich an der Unterseite des Gerätes.

 

OXYMAT 5E

Das Gehäuse ist für das 19"-System konzipiert. Es besteht keine gasdichte Trennung zwischen Analysierteil und Auswerteelektronik.

Die Bedienung erfolgt über eine an der Frontplatte montierte, wasserdichte Folientastatur. Gasanschlüsse und elektrische Anschlüsse befinden sich an der Rückseite des Gerätes.

 

Werkstoffe der meßgasführenden Teile

Meßkammer wahlweise aus rostfreiem Stahl (W.-Nr_ 1.4571) oder Tantal

Gasweg wahlweise in Schlauch (FPM oder PTFE)

oder Rohr (W.-Nr. 1.4571)

Sonderausführungen z.B. in Hastelloy sind möglich.

 

 

Technische Daten

Anzahl der Meßbereiche                                                  max.4

- frei parametrierbar innerhalb der Meßspannen                  von 0,5 bis zu 100 % 0 2

(je nach Bestellung) bei einem Meßgasdruck                    von 2,0 bis zu 100 % 0 2

von 1 bar (absolut)                                                           von 5,0 bis zu 100 % 0 2

Die entsprechendenMeßbereiche sind auch mit unter‑

drücktem Nullpunkt möglich, jedoch mit kleinster

Meßspanne

- bei Vergleichsgas Luft                                                   1 % 0 2 (z.B. Meßbereich 20,5 bis 21,5 % 0 2 )

- bei Vergleichsgas 02                                                     2 % 0 2 (z. B. Meßbereich 98,0 bis 100 % 0 2 )

Kleinstmögliche Meßspanne bei beheizter Ausführung       2% 02

Automatische Meßbereichsumschaltung                           anwählbar

                                                                                    Hysterese:

Umschaltung zum MB mit dem größeren MB-End­wert bei 90 % der Meßspanne des MB mit dem kleineren MB-Endwert,

MB-End‑wert bei 80% der Meßspanne des MB mit dem kleineren MB-Endwert.

Ausgangssignale

Analog                                                                           0/2/4 bis 20 mA , galvanisch getrennt (Auflösung ca. 0,1 %; max. Bürde ca. 750 0)

digital                                                                             serielle Schnittstelle (je nach Bestellung), nicht potentialfrei!

Parametriermöglichkeiten (zur Einstellung geräte-              Grenzwerte. Meßspannen,

spezifischer Parameter über Bedienfeld)                            Meßwertspeicherung, Zeitkonstante, dreistufiger Code zur Sicherung gegen unbe‑

                                                                                    fugte oder unbeabsichtigte Bedienung

Geräteausgang                                                               Potentialfreie Kontakte für

                                                                                    - Meldesignal: Messen/Kalibrieren

                                                                                    - Statussignal: Ready/Not Ready

- Vier Grenzwertrelais, ein- und ausschaltbar, (max. 24 V/1 A), den Meßbereichen frei zuzuordnen.

- Vier Kontakte für Meßbereichskennung (max. 24V/1 A)

- Magnetventilsteuerung (nur bei Zusatzplatine für autom. Kalibrierung), max. 24 V/1 A

Geräteeingang                                                                Für die Meßbereichsfernumschaltung werden vier potentialfreie Kontakte benötigt.

Meßwertanzeige                                                             digitale Konzentrationsanzeige (41/2 Stellen mit Fließkomma)

Auflösung der Digitalanzeige                                            abhängig vom gewählten Meßbereich, s.Tabelle 12.1

Welligkeit des Ausgangssignals                                       <0,5 % vom Signalendwert

Rauschen                                                                       0.1 bis 1 % von der Meßspanne, meßbereichsabhängig

Reproduzierbarkeit (es gilt jeweils der größere Wert)          50 ppm oder ± 0,5% der kleinsten Meßspanne

Kennlinie                                                                        linear

Meßgasdurchfluß                                                            0,3 bis 1,0 I/min

Zulässiger Meßgasdruck                                                 max. 1,5 bar (absolut) bei verschlauchter Ausführung

max. 1,8 bar (absolut) bei verrohrter Ausführung

Zulässiger Spülgasüberdruck                                           max. 250 mbar

Drift                                                                               Nullpunkt:        ± 0,5 % je 3 Monate von jeweils kleinster Meßspanne.

Ausschlag:                                                                     ± 0,5% je 3 Monate v.Meßspanne bei

konstanter Temperatur und konstantem Druck.

                                                                                    OXYMAT 5F     OXYMAT 5E

Anzeigeverzögerung (T 90 = 90%-Wert),                              min. 1,5s            min. 3,5 s

bestehend aus:

- Signalverzögerung Ts (beeinflußbar über Fkt. 13)             0 ... 100s           0 ... 100 s

- Totzeit (Ausspülzeit des Gasweges im Gerät bei 1 l/min) ca. 0,5s             ca. 2,5 s

- Zeit für geräteinterne Signalverarbeitung                          ca. 1 s               ca. 1 s

Anwärmzeit (98 % des Sollwertes)                                   ca. 30 min

Anwärmzeit bei beheizten Geräten                                   ca. 2 h

Temperatur des beheizbaren Analysierteils                        80 °C, 110 °C oder 130 °C, einstellbar

Einfluß

   des Luftdruckes

       ohne Druckaufnehmer                                               ±2 % der Meßspanne bei ± 1 % Luftdruckänderung

                                                                                    Achtung!          Liegt der physikalische Nullpunkt außerhalb des Meßbereiches, wird der Druckfehler wesentlich größer!

mit Druckaufnehmer                                                        < 1 % der Meßspanne pro 100 mbar Meßgasdruckänderung

der Umgebungstemperatur                                               Kleinstmögliche    Meßfehler,

                                                                                    Meßspanne lt       bezogen auf je‑

                                                                                    Typenschild          weilige Meßspanne

                                                                                    0,5%                    1% 10 K

                                                                                    2%                      0,5% /10 K

                                                                                    5%                      0,5% /10 K

                                                                                    bei beheiztem Analysierteil. doppelter Fehler

des Meßgasdurchflusses                                                 <1 % der Meßspanne (<2 bei Meßspanne bei 0,5 % 0 2 ) bei Meßgasdurchfluß 0,3 bis 1l/min und Vergleichsgasdurchfluß 3 bis 10 ml/min bei 25°C

des Restgases                                                               Nullpunktabweichung entsprechend der para- oder diamagnetischen Abweichung des Restgases vom Nullgas (siehe Tabelle 12.3)

der Versorgungsspannung                                               ≤0,1% der Ausgangssignalspanne bei -15 % bis + 10 % Netzspannungsänderung

zulässige Umgebungstemperatur

  im Betrieb                                                                    0 bis 45 °C (Bei Beheizung auf 130 °C: 40

                                                                                    °C)

  bei Lagerung und Transport                                            -30 bis + 70 °C

zulässige Umgebungsfeuchtigkeit

  im Betrieb                                                                    max. 90%

  bei Lagerung und Transport                                            max. 95 %, im Jahresmittel ca. 80%

Netzanschluß                                                                 AC, 48 bis 63 Hz

                                                                                    110/120/220/240 V

Leistungsaufnahme                                                         etwa 100 VA, bei beheizter Ausführung ca. 350 VA

Schutzart

  OXYMAT 5E                                                                 IP 20 nach DIN 40050

  OXYMAT 5F                                                                 IP 65 nach DIN 40050

Gasschwadensicher nach VDE 0165/DIN 57165, Abschnitt 6.3.1.4

Abmessungen (Ei x H x 7)

  OXYMAT 5E                                                                 483 mm (19") x 177 mm x 408 mm (Bild 12.1a)

  OXYMAT 5F                                                                 438 mm x 480 mm x 300 mm (s. Bild 12.1 b)

Gewicht

  OXYMAT 5E                                                                 etwa 18 kg

  OXYMAT 5F                                                                 etwa 30 kg

  beheizte Ausführung                                                      etwa 35 kg

 

Meßbereich (% 0 2 )            Auflösung

0,5 - 1,5                           0,001

1,5 - 3,5                           0,002

3,5 - 7,5                           0,005

7,5 - 15                            0,01

15 - 35                             0,02

35 - 75                             0,05 .

75 - 100                           0,1

 

Tabelle 12.1 Auflösung der Digitalanzeige

Bei Meßbereichen mit unterdrücktem Nullpunkt wird die Auflösung aus der Meßspanne ermittelt Sie wird dann unter Umständen durch die 4 1/25tellen der Digitalanzeige eingeschränkt.

 

 

 

Gruppo prodotti: Analizzatori-Misuratori di Gas

Non è stato trovato alcun prodotto corrispondente alla selezione.