Shimadzu SPD 10Avp
Objektnummer | B00013498 |
---|---|
Seriennummer | 013498 |
Nome oggetto | Shimadzu SPD 10Avp |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
model: SPD 10Avp
annotation: Dokumente engl .
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Specifications
Light source
D2 lamp
Wavelength range
190 ~600 nm
Spectral bandwidth
8 nm
Wavelength accuracy
± 1 nm
Wavelength reproducibility
± 0.1 nm
Drift
2 x 10-4 AU/ hour Max. ( constant room temperature )
250 nm
Noise level
± 0.35 x 10-5 AU Max. (2 sec time constant), ±0.5 x 10-5 AU Max. (1 sec. time constant)
250 nm
Response
Selectable in 10 steps corresponding to time constant 0.05, 0.1, 0.5, 1.0, 1.5, 2.0, 3.0, 6.0, 8.0, 10.0 seconds
Range
0.0001 2.56 AUFS in 0.0001 AUFS step
Zero adjustment
Auto zero, baseline shift
Cell (Optical path length, volume)
10 mm, 8 µL (Preparative cells, semi-micro cell, non-metal cell are optionally available)
Simultaneous dual wavelength measurement
Selectable, two wavelengths in 190 370nm or 371-600nm range
Ratio chromatogram display
Output ratio of 2 selected wavelengths
Wavelength scanning
Wavelength steps 1 5 nm, in 5 steps (2 5nm when W lamp is used)
Scan speed 10 50 nm/sec, 5 steps (according to wavelength step setting)
Time program
Controlled by detector unit itself or by system controller wavelength (2 wavelengths), auto zero, range, marker, response, wavelength scan, event, polarity, lamp ON/OFF, loop
Polarity switching
Possible
Output
Recorder 10 mV
Integrator 0.5, 1, 2, 4, 1.25, 2.5 AU/V in 6 steps
Dimensions, weight
260W x 420D x 140H mm, 13 kg
Ambient temperature range
4 ~ 35°C
Power requirements
100V±10V, 150 VA, 50/60Hz
120V±10V, 150VA, 50/60Hz
230V±20V, 150VA, 50/60Hz