Shimadzu system controller SCL 10A VP.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00018296
Seriennummer 018296
Nome oggetto Shimadzu SCL-10A
Stato Archived Product

Gruppo prodotti: HPLC-Miscellaneous

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Shimadzu

model :                   SCL-10A

annotation :           Dokumente engl.

 

 

SCL-10Avp System Controller

 

This system controller is designed to be connected to the various units in the. Shimadzu LC-10N10Avp High Performance Liquid Chroma.tography series, and control their functions.

This controller centralizes control of a wide variety of system configurations, and can also permit fully operation.

  • By means of specially designed fiber optic hnk interfa.ces, the controller can be connecte,d to the pump, column oven, detector, auto injector and fraction collec­tor in the LC-10A/10Avp series.

Use of a sub-controlier will also permit the controlier to be connected to and con­trol options such as special vaives and a heliurn degasser.

  • An fiber optic link interface for connection to a Chrornatopac is supplied. This interface permits operation in tandem with a Chromatopac, or system control by

BASIC programs vvritten on the Chromatopac.

  • An optional RS-232 cable can be used to connect the controiler to a PC, for PC

control. (When the controlier is under PC control, the fiber optic |inkin1erface

cannot be used.)

  • The controller's LCD screen permits setting anaiysis conditions for the connected

devices , provides displays relating to control operation, and displays the status of each device for monitoring puposes during ana.lysis.

Additionally, the screen's graphic functions can provide graphic displays of scan data from the detector, chromatograms from the fraction collector, and other data that facilitate pararneters settings.


Display panel

LCD with back light                                          320 x 240 dots

Operation panel

                                                                        Fixed function keys            22 keys

Keys

                                                                        Variable function keys        5 keys

Flexible disk drive

Drive                                                                 Double sided high density

Diskette                                                            3.5" 2HD

Capacity (forrnatted)                                        approx. 1.6 MByte.

Input terminals

External START signal Input (MAN.INJ iN)      x1 (relay contact input)      Actuated by time

                                                                                                                  program or by

EPiROR signal input (ALARM IN)                    x 3 (relay contact input)     START, STOP or

                                                                                                                  ERROR

Common output terminals (EVENT1 ,2,3,4 )    x 4 (relay contact output)   signals, as applicable

External power outlet control (AC REMOTE) x1 (for multiple terminal box )

Optical link (OFT LINK) connector                  x1 (for Chrornatopac)

RS-232C connector                                         |x1 (for connection to PC)

REMOTE connector                                        x 8 (for controlling HPLC units)

Compatible HPLC units

Pumps                                                             Up to 3 units

Auto injector                                                     1 unit

Coiumn oven                                                    1 unit

Detectors                                                         1 or 2 units

Fraction collector                                             1 unit

Sub-controller valve intertace                          1 unit
Equipment below can be connected via sub-controller (or valve Interface)

2-position rotary valves                                    2 units

6-position rotary valves                                    2 units

Solenoid valve unit                                           1 unit (cannot be connected via valve interface)

Helium degasser                                              1 unit (cannot be connected via valve interface)

Syringe unit                                                      1 unit (cannot be connected via valve interface)

Parameter files

Analysis flies                                                    Number of flies                   20

( parameters ,                                                    Time program steps          400 (total of all flies)

time programs)                                                Program time                     0.01 - 9999.9 minutes

Fraction collector Nes                                      Number of files                   10

( parameters ,                                                    Time program steps          100 (total of all flies)
time programs)                                                Program time                     0 ,33 - 9999.9 minutes

Auto injector analytical                                     Number of steps                102

sequence file

Auto injector                                                     Nurnber of files                   20

pre-treatrnent files                                            Program memory capac. 250 Bites for each file

Data files

Scan data files           Number of files               3 (one for background, two for samples)

*Reception and display of scan data from SPD- 10A( V)vp possible

Chromatogram files   Number of files               1 (for the fraction collector)

                                                            * Reception and display of chromatograms from   FRC-10A possible

Pump control

Control modes                                                 Isocratic, high-pressure gradient, low-pressure

                                                                        Gradient, constant pressure

Parameters                                                      Flow rate, pressure, concentration, upper and lower pressure limits l

Gradient proflies                                               Step, linear and exponential functions (all at multiple levels)

Auto injector control

Parameters                                                      Sample injection, number of repeat lnjections, analysis duration or analysis file No., pre-treatment file No., fraction collector file No.

Column oven control

Parameters                                                      Oven temperature., upper temperature limit

Detector control

Parameters                                                      Detection wavelength, RANGE, time constant,      lamp switching, scan conditions, etc.

Fraction collector control

Parameters                                                      Fractionation conditlons, etc., peak detection conditions, various analysis conditions

Data backup

All condition setting files (listed in 6. above) saved by battery backup if power failure occurs

Self-diagnosis and safety.measures

Memory check

Upper and lower pressure limits, upper temperature limit, monitoring of lamp current, motor speed, etc.

Operating conditions, dimensions, weight

Power supply voltage

Voltage range depends on Part No.:

Part No. 228-34350-91: 100-120V AC, 50 ,/ 60Hz, 320VA, 4A fuse

Part No. 228-34350-92: 100-120\ ,, AC, 50/6'0Hz, 320JA, 4A fuse

Part No. 228-34350-38: 220-240V AC, 50/60'Hz, 320VA, 2A fuse

Ambient temperature                                       4-35°C

Outer dirnensions                                           Width 260 x depth 420 x height, 140 mm (excluding protruding parts)

Weight                                                              6kg approx.

 