Soldé

Shimadzu CS-9301 PC

Seriennummer: 016959
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Shimadzu Dual wavelength scanning densitometer CS-9301 PC. With mercury lamp. Powersupply.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00016959
Seriennummer 016959
Nome oggetto Shimadzu CS-9301 PC
Stato Archived Product

Gruppo prodotti: Densitometri per TLC

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Shimadzu

model:                   CS-9301 PC

annotation:           Dokumente engl.

CS-9301PC is the latest scanning densitometer, that fully utilizes the Shimadzu’s original photometric system and a host of software programs operating in a multiwindow environment.

It readily permits highly precise denistometry of thin layer chromatograms, one-dimensional and two-dimensional electrophoregrams, and even of micro plates (option required).

Wide Field of Applications

The CS-9301PC provides reliable densitometry of TLC, DNAs electrophoretic gels, blotting films, papers, ordinary films, and fluorescent micro plates, and even study of solid surfaces.

Measurement in Various Modes

Choice of transmission-absorpiton, reflection-absorption, reflection-fluorometric and transmission-fluorometric modes. The measuring wavelength is freely selectable from ultraviolet to visible regions. Many samples can be measured rapidly in automated operation.

High Quantitative Accuracy Ensured by Rapid Zigzag Scanning Method

The zigzag scanning method, using the flying spot method, will eliminate errors caused by irregular shape of chromatographic spots which cannot be reproducibly measured with a linear scanning method.

A Wide Variety of Options

- Two-dimensional spectrophotometric image processing program.

- Micro plate measuring attachment

These options may be combined to permit processing of complicated two-dimensional data and measurement of micro plates.

Easy Manipluation of Complicated Data

The MS-Windows environment ensures ease of manipulating complicated data.

Specifications

Wavelength scanning range    200 - 700nm

Measuring range                      200 - 650nm

Measurement method              Double-bearn monitor, dynode feedback

Photometry                              Reflection absorption                         Single er dual-wavelength method Transmission absorption

                                                Reflection fluorophotometry   Optional Mercury lamp, or xenon

                                                Transmission fluorophoto-    lamp is required.

                                                metry                                     Transmission fluorophotometry is available only if a model with microplates is used.

Measurement functions          Logging, of absorption spectr., and densitogram profiles, automatic area calculation, and printout of quantitation results

Report formal                          Reports produced by a printer connected to the personal computer.

Sample scanning                    Selectable between two alternative modes of scanning:zigzag and linear.

Zigzag swing width :Continuously variable fron 1 to 16mm (positive integer)

Scanning pitch in Y-axis direction: 0.01, 0.02, 0.04, 0.10, er 0.20min

Scanning range                        X-axis direction: 5 - 195min

                                                Y-axis direction: 2 - 18irnm

Slit sizes                                  16 sizes (Wmm x Hmm)

0.05x0.5, 0,05x1.0. 0.05x2.0, 0.2x1.0, 02x2.0, 0.4x 1.0, 0,40.4, 0.4x2.0, 0.4x5.0e 0.410.0, 0.4x16.0, 1.0x1.0, 1.0x2.0. 1.0x5.0, 1.0x10.0, and 1.0x16.0

Lamps                                      Ultraviolet region         Deuterium Iamp

                                                Visible region              Halogen lamp

                                                Fluorophotometry       Mercury, xenon Iamp, or Laser (options)

Sample type                             Maximum (hin-layer plate size ;200mm x 200mm), up to 3mm thick

                                                Paper chromatography paper

                                                Electrophoretic gels

                                                Microtiter plates wich optional accessory

Weight                                      43kg

Power consumption                 500VA

Part of labexchange logo
Search engine powered by ElasticSuite