Shimadzu AA 6800
Objektnummer | B00014619 |
---|---|
Seriennummer | 014619 |
Nome oggetto | Shimadzu AA 6800 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Shimadzu
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
The Atomic Absorption Spectrophotometer AA-6800 incorporates two background correction functions, the D2 method (Deuterium Lamp method) and the SR method (Self-Reversal method), enabling selection of the appropriate method for the measurement sample.
The AA-6800 allows you to change the measurement mode while automatically switching the atomizer, thus enabling quick and easy switching back and forth between flame measurement and furnace measurement. In addition, wide ranging measurement operations are available, from manual Operation to automatic continuous measurement of multi-elements wich the use of an autosampler (ASC-6100). This enables selection of the appropriate combination to match the number of elements and samples to be analyzed as well as the skill of the operator.
The PC software controlline, the AA-6800 operates an the MS-Windows", and using the Wizard for parameter setting enables an operator, even an beginner of atomic absorption spectrophotometer, to make measurement conditions easily.
The GFA-6500 is the graphite furnace atomizer adopted for use with the Atomic Absorption Spectrophotometer AA-6800. With the graphite furnace connected to the Instrument, quantitative analysis of elements may be conducted using the furnace method. Following is a description of GFA-6500 features.
(1) With the incorporated high sensitivity optical-thermal sensor and the automatic temperature correction function employing current control regions, simple temperature correction and accurate temperature repeatability are achieved.
(2) Temperature control via the optical-thermal sensor is conducted from 400°C, thus making possible accurate temperature control from anhing to atomization.
(3) At sample atomization, use of the high sensitivity mode allows trace analysis of even greater sensitivity and higher precision than previously possible with live of Instruments.
(4) Precise inner gas current control is possible at each heating stage and automatic switching of the gas type allows composition of flexible temperature programs. These features make the GFA-6500 extremely effective in analyzing a wide variety of sample typen.
AA-6800F/6800G Common Specifications |
||
Spectro photometer |
Measurement Wavelength Range |
190~900nm |
Mounitng |
Aberration-corrected Czerny-Turner mount |
|
Bandwidth |
0.1, 0.2, 0.5, 2.0, 5.0 nm (6-step automatic switching) |
|
Lamp |
Number of Lamp Sockels Photometrie Method |
8 lamp sockets, 2 lamps simultanously lit (1 for warming up) High-speed seif reversal method (BGC-SR) High-speed 2-frequency simultanous measurement (BGC-D2) |
Lamp Mode |
EMISSION, NON-BGC, BGC-SR, BGC-D2, D2 |
|
Data Processing |
Software Environment Parameter Setting |
MS-Windows TM 95 Wizard Method |
Measurement Mode |
Flame continuous method, Fumace method |
|
Concentration Conversion Mode
Repeat Measurement |
Calibration Curve (selectable arnong 1st, 2nd, 3rd order function) Standard addition method/Simple Standard addition method (1st order function) Max. 10 repetitions Indication of Average, Standard deviation (SD) and Relative Standard Deviation (RSD) Exclusion of deviant value based an SD value and RSD value |
|
Baseline Correction |
Automatic baseline dritt correction using electrical double beam Signal processing (Furnace) |
|
Sensitivity Correction |
Automatic calibration curve correction System by sensitivity observation. |
|
Table Data Processing Functions Multitask |
Actual concentration calculation using Weight factor, Dilution factor, Volume factor and Correction factor. Word processor Software or the like can be used while executing measurement. |
|
Loading Parameters |
Template function |
|
Procedure/Result Display |
MRT Work Sheet (MRT: Measurement Result Table) |
|
Result Print |
Summary Report |
|
QA/QC |
Correlation factor, LCS, SPK, Sample upper limt, %RSD |
|
Power Requirements
Dimensions, Weight |
AC100, 120, 220, 230, 240V switching incorporated, 600VA, 50/60Hz Additional power for personal Computer is necessary‑ W 1080 X D550 X H460mm, 100kg (including gas controller. not including PC) |
|
|
Ambient Temperature Range |
10°C ~ 35C |
Ambient Hurt udity Range |
45% ~ 80% (less than 70% if temperature is over 30°C) |
AA-6800F Specifications |
||
Burner Unit |
Type |
Air-cooled pre-mix type |
Bunter Head |
Pure Titanium |
|
Nebulizer |
Pt-Ir capillary with Teflon orifice, Impact bead is inseparable. Fluoric acid is usable. |
|
Chamber |
Polypropylene |
|
Positioning |
Bumer/Fumace automatic switching by motor drive Automatic searching for optimum burner height |
|
Gas Controller |
Flow Rate/Pressure Control |
Automatic flow rate settin-, Automatic searching for optimum gas flow rate |
Safety Measures |
Automatic gas leak check Air-C 2 H 2 flame priority ignition Air/N 2 0 auto switching with C 2 H 2 flow rate monitor (optical Sensor) Prevents raw gas discharge Prevents usage of wrong burner head Pressure monitor to prevent flashback at abnormal pressure Safety extinction by automatic detection of momentary power failure Drain tank water level monitor to prevent flashback |
AA-680OG Specifications (GFA-6500 Specifications) |
|
Heating Temperature Range |
Ambient~3000 °C |
Heating Control Method |
Drying: Current control method Ashing/Atomizing: Optical temperature control method |
Heating Parameter settings |
Max. 20 stages Heating mode: RAMP/STEP Inner gas type: 2-line switching High sensitivity setting Furnace concentration boost cycle: Max 20 times Innen gas flow rate: 0~1.5 L/min Optimum fumace program search function |
Cooling water/Ar Consumption Power Requirements |
Cooling water: 1.0 L/min or larger Gas: Max. 3.0 L/min AC200V Max.6kVA, 50/60Hz |
Power Supply Unit, Dimension and Weight |
W42XD29XH460 (innt). 442 (Power supp1.v unit fins in space behmd 14 mit unit. Main unit width on1.v needs to be considered.) |
Optional
ASC-6100
By connecting to the Shimadzu Atomic Absorption Spectrophotometer, the ASC-6100 performs the functions as the autosampler for flame absorption measurement. Also, when G attachment ASK-6100 is mounted, the ASC-6100 can perform a wide variety of following functions automatically in the furnace quantitative measurement by linking wich the Shimadzu Atomic Absorption Spectrophotometer main unit.
(1) Sample dilution
(2) Reagent addition
(3) Mixture of samples and reagents at the mixing port
(4) Combined rinsing of mixing port
(5) Automatic dilution and re-analysis for off-scale measurements due to excessive concentration of unknown samples
(Dilution rate is automatically set. Possible dilution rate is 300 times at maximum.)
(6) Injection of high accuracy sample. Sampling amount can be changed in the unit of 1µl.
(7) Booting of sample concentration in Fumace measurement
For Flame and Furnace |
|
Control |
By RS-232C with AA |
Function |
Origin search Self diagnosis Automatic rinsing Automatic preparation Random access |
Number of sample |
8 for Reagent 60 for Sample (random access available for both) |
Sample cup |
Sample : 15ml (testing tube for Flame) or 2ml (vial for Furnace) Reagent : 20ml |
Rinne nozzle |
Discharge rinsie liquid from nozzle (for Furnace) Intake rinse liquid from nozzle (for Flame) |
Bottle for rinse liquid |
2l |
Power |
AC100V ~ 240V (auto sensing), 100VA |
Dimension Weight |
For Flame : W330 x H320 x D295mm. 7.5kg For Flame and Furnace : W430 x H320 x D360mm, 15kg |
For Furnace only |
|
Function |
Automatic dilution Automatic reagent addition |
Syringe |
250µl |
Injection volume |
2 --100µl |
Reproducibility |
1% R.S.D (20µl) |
Cary over |
Rinsing port :under 0.00001 Mixing port :under 0.00001 |
Rinsing Mixing port |
With rinse liquid With next sample |
Mixing |
In the mixing port Maximum volume for preparation: 0,6ml |
Number of reagent for addition |
Maximum 4 Number of liquids for mixing Calibration method : Maximum 5 (one sample + 4 reagents) Standard addition method : Maximum 6 (one sample + one Standard + 4 reagents) |
Auto dilute and re-analyze |
When the absorbance exceeds the range of the calibration curve: The Optimum dilution ratio is automatically set. (When it can not be calculated ,the dilution ratio is fixed at 10 times.) |