Soldé

Shimadzu AA 6701

Seriennummer: 008833
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Shimadzu AAS Modello AA protossido di azoto e 6701. acetilene torcia. GraphitrohrofenGFA 6500. campionatore automatico ASC 6000. porto campionamento Micro. 18 HKL di. D2 UK.Mess e software di controllo. Nuovo prezzo: 36,300, - Euro.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00008833
Seriennummer 008833
Nome oggetto Shimadzu AA 6701
Stato Archived Product

Gruppo prodotti: Assorbimento Atomico

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Shimadzu

Modell:            AA 6701

Kommentar:   Dokumente engl.

The AA-6701/6601 Atomic Absorption Spectrophotometer incorporates two background correction function, the D 2 method (Deuterium Lamp method) and the SR method (Self-Reversal method), enabling selection of the appropriate method for the measurement sample.

Listed below are the measurement modes which are supported.

(a) Flame Measurement (Continuous Sampling)

(b) Flame Measurement (Microsampling)

(c) Furnace Measurement

The AA-6701 allows you to change the measurement mode while automatically switching the atomizer, thus enabling quick and easy switching back and forth between flame measurement and fumace measurement.

In addition, wide ranging measurement operations are available, from manual operation to automatic continuous measurement of multiple elements with the use of an autosampler (ASC-6000). This enables selection of the appropriate combination to match the number of elements and samples to be analyzed as well as the skill of the operator.

Software operations are easily performed, thanks to the operating environment employing the MS-Windows GUI (Graphical User Interface). In addition, the MDI (Multi Document Interface) is adopted, so that parameter setting windows, calibration curve window, measurement results window and other necessary windows may be displayed on the screen simultaneously, to enable operations while maintaining a good perspective of the overall conditions.

Specifications

Spectrophotometer

Wavelength range

190 to 900 nm

Mounting

Aberration corrected Czerny-Turner mounting

Bandwidth

0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm (6-step automatic)

Lamp

Number of HC lamps

8-lamp turret, 2 lamps simultaneously lit (1 for measurement and 1 warming up for next measurement)

Background correction

BGC-SR (high-speed self-reversal method) and BGC-D 2 (D2 lamp method;high-speed, dual-frequency simultaneous measurement)

Lamp mode

Emission, Non-BGC, BGC-SR, BGC-D 2 and D 2

HC lamp database

Lamps in use may be registered for tracking their hours in use.

Data processing

Software requirements

MS-Windows Ver 3.10 or later

Operational parameter display

MDI (Multiple Document Interface) method

Window sizes

Automatic adjustment by Quick View functions

Measurement mode

Flame continuous, flame microsampling, and furnace modes

Concentration computation

Calibration curve method (choice of 1st, 2nd, and 3rd order functions), Standard addition method (1st order function)

Repeat analysis

Up to 100 repetitions. Mean value, standard deviation (S.D.) and coefficient of variation (C.V) displayed.

Automatic exclusion of deviant values by setting S.D. and C.V.

Baseline correction

Automatic drift correction using electrical double beam signal processing in both flame microsampling and furnace modes.

Sensitivity correction

Recalculation after drift correction

Tabular data processing

Calculation of final concentrations from sample volumes, dilution ratios, fill-up volumes in sample dissolution factors.

Multitasking

Spreadsheet software or word processing software may be executed during measurement.

Recall of operational parameters

Template functions available.

Procedure/result display

Concentrated MRT (Measured Result Table) system

Report generation

Quick report, Run time report, and Summary report

Power requirements

100, 120, 220, 240 VAC, switch selectable. 50/60 Hz. 600 VA.

The computer and its peripherals require additional power.

Dimensions and weight

1080 W x 550 D x 460 H mm, 100 kg (including the gas controller and not including the computer and its peripherals)

Burner Unit

Type

Air cooled premix type

Burner head

Stainless steel (titanium optional)

Nebulizer

Pt-Ir capillary with Teflon orifice

Chamber

Polypropylene

Positioning

Automatic search of optimum burner height (AA-6701/6701 F)

Automatic flame-furnace switching by motor (AA-6701/6701 F)

Gas Control

Flow rate/pressure control

Automatic control and automatic optimization

Safety measures

Automatic gas leak check, Air-C 2 H 2 flame priority ignition, Air-N 2 0 automatic changeover with flow rate monitor using optical sensor, Prevents flowing out of unburnt fuel, Prevents usage of wrong burner head, Flashback prevention with pressure monitor, Automatic flame extinction when power failure, even an instantaneous one, occurs., Drain tank monitor to prevent flashback

Heating temperature range

Ambient to 3000°C

Heating control

Drying: Current control with automatic temperature calibration

Ashing/atomization: Temperature control with optical sensor

Heating conditions

Up to 20 stage, programming; RAMP and STEP, heating modes; choice of two, inner gases; high sensitivity mode available; up to 20 times, concentration boosting in the furnace; 0 to 1.5L/min. inner gas flow rate setting in 0.1 L/min. increments

Cooling water/argon gas consumption

Cooling water: 1.0 L/min. or higher, Argon: 3.0 L/min. maximum

Power requirements

200 VAC, 50/60 Hz, 6 kVA max.

Dimensions and weight of power supply unit

642W x 247D x 460H mm, 44 kg (to be placed in the rear space of the AA main; no additional space required. )

Guaranteed Sensitivity

Flame analysis

Furnace analysis

Abs

0.45 Abs. for 4 ppm Cu

0.18 Abs. for 20 µL of 1 ppb Mn

Personal Computer Requirements

OS: DOS, MS-Windows ver 3.10, CPU: 80486DX-33 or higher,

CRT: VGA or higher, RAM: 8 Mbyte or larger,

Hard disk: 120 Mbyte or larger, 3.5" Floppy disk drive: One or more units

Part of labexchange logo
Search engine powered by ElasticSuite