Shimadzu AA 6501
| Objektnummer | B00014178 |
|---|---|
| Seriennummer | 014178 |
| Nome oggetto | Shimadzu AA 6501 |
| Stato | Archived Product |
Gruppo prodotti: Assorbimento Atomico
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Shimadzu
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
SPECIFICATIONS
AA-6501 Atomic Absorption Spectrophotometer
Spectrophotometer
|
Analysis Method |
Atomic Absorption
|
Lamp Mode |
HCL mode: AA analysis without background correction. BGC-SR mode: Background correction. by Self Reversal BGC-D 2 mode: Background correction. by D 2 lamp D 2 mode: Measures molecular absorption, scattering, etc. Emission mode: Flame emissionanalysis of elements |
Flame, Microsampling flame Furnace |
|
||||
|
Molecular absorption |
|
||||||||
|
Flame emission |
|||||||||
|
Flame only |
|
||||||||
|
Wavelength range |
190 ~ 900nm |
|
|||||||
|
Background correction |
Self reversal and Deuterium lamp (high-Speed, dual-frequency simultaneous measurement) |
||||||||
|
HC lamp |
Current |
Low level: 0 ~ 60mA High level: 0 ~ 600mA (used with BGC-SR) |
Two-level pulse lighting |
|
|||||
|
Frequency |
BGC-SR: 100Hz Hollow Cathode Lamp/D 2 mode: 500Hz |
|
|||||||
|
No. of lamps |
8-lamp turret 2 lamps simultanously lit (1 for measurement; 1 warming up for next measurement in multielement, sequential analysis) |
||||||||
|
D 2 lamp |
Type |
Hot cathode type |
|
||||||
|
Lighting System |
Pulsed lighting |
|
|||||||
|
Frequency |
1000Hz |
||||||||
|
Current |
250mA |
|
|||||||
|
Beam balance |
Automatic 2-step gain adjustment |
|
|||||||
|
Mounting |
Aberration-corrected Czerny-Turner mounting |
|
|||||||
|
Bandwidth |
0.1, 0.2, 0.5, 1.0, 2.0, 5.Onm (6-step automatic switching) |
|
|||||||
|
Wavelength setting |
Linked with slit, automatic setting by peak search using Precision Direct Scan Drive (PDSD) |
|
|||||||
|
Detector |
Photomultiplier R787-04 |
|
|||||||
|
Power requirements |
100, 120, 220VAC switching, 600VA, 50/60Hz |
|
|||||||
|
Dimensions, weight |
W1080 x D545 x H470, 100kg (including the gas control System) |
|
|||||||
|
|
|||||||||
Data Processing
|
Mode |
Calibration curve (10 points. max, including blank) - selectable among 1st, 2 nd , 3 rd order function. Shift through origin capability. Standard addition method (10pt. Max, 1 st order function. |
|||
|
Accuracy enhancement |
Determination of calibration curve by least square method |
|
||
|
Value averaging based on repeat measurement (up to 10 repetitions) |
||||
|
Automatic exclusion of deviant values, additional Tuns, and recalculation |
||||
|
Calibration curve recording |
Automatic recording |
|
||
|
Peak signal processing |
Transient Signals in furnace/microsampling flame analysis |
|
||
|
Repeat analysis |
Max. 10 repetitions Mean value and Coefficent of variance (C. V.) displayed. Automatic exclusion of deviant values based on number of data, maximum number of repetitions and C. V. |
|||
|
Baseline correction |
Automatic drift correction using electrical double beam signal processing in Peak Height and Peak Area mode. |
|
||
|
Calibration curve drift correction |
The calibration curve equation may be corrected for drift by measuring standards interdispersed among the samples. The data stored in the memory are automatically corrected. The corrected calibration curve is applied in subsequent analysis. |
|||
|
Sample concentration calculation |
Determined by External Standard or Standard Addition methods. Sample weight and dilution factors are automatically calculated. |
|||
|
Data processing |
Weights, volumes, dilution factors, and correction factors can be used to calculate concentration of initial Sample. Data processing table may be customized. |
|
||
|
Data Recording
|
Printer |
Thermal-8 dots/mm (head resolution), 20 dots/mm (paper feed direction resolution). Optional color plotter available. |
|
|
|
Chart paper |
Roll-type thermal paper, 210mm wide and 30m long |
|
||
|
Data printout |
Sample number, Replicate number, Peak height, Area count, Background height, C. V. value. Analysis conditions, Calibration curve, Absorbance curve. Sample concentration calculation tables, Table of data processing results, Furnace heating program (graphic display), and Hard copy of screen display. |
|||
|
Absorbance plot |
Full scale Response
Chart feed |
Absorbance, 9.9999 to +9.9999 4-step changeover, bar graph display, peak signal (transient signals are recorded in the case of Furnace/ Microsampling flame analysis) 1.25, 2.5, 5, 10, 15, 20, 25, 30mm/sec |
||
Signal processing
|
Flame-continuous Aspiration method |
Pre-spray time: 1 to 99 sec, Integration time: 1 to 99 sec. Selectable pre-spray may be set before each replicate and/or before each sample. |
|
Furnace/ Microsampling flame |
Peak height, Peak area (Transient signal height, area display) |
Display
|
High resolution 14 inch color CRT (640 dots x 400 lines). Each item is displayed in user specified color. Displayed items (in addition to data printout); - Transient signal zoom display - Help messages - Autosampler syringe/sample nozzle position i nformation - System setting |
Burner/Gas Control
|
Burner |
Type |
Air-cooled pre-mix type with 10cm slot (5cm slot for high temperature flame optional) |
|
Burner head |
Stainless steel (titanium optional) |
|
|
Nebulizer |
Pt-Ir capillary with Teflon orifice |
|
|
Impact beads |
Glass (Teflon-coated optional) |
|
|
Chamber |
Polypropylene |
|
|
Flame |
Automatic ignition/extinction |
|
|
Positionin |
* Vertical, horizontal, and angular positioning *Vertical and horizontal positioning via keyboard. Automatic Optimum positioning for each element. * Automatic positioning on the optical axis in flame analysis |
|
|
Gas Control |
Flow rate/ pressure control |
* Pressure/flow rate control, automatic flow setting * Fine adjustment of fuel gas flow rate possible from keyboard (O.1L/min. steps) * Automatic optimization of gas conditions for each element |
|
Safety measures |
* Automatic gas leck check when turning on the power (10min check: cannot be cancelled) * Air-C 2 H 2 flame priority ignition * Air/N 2 0 automatic changeover with flow rate monitor using optical sensor * Flashback prevention with optical sensor monitor * Automatic flame extinction when power failure occurs * Prevents usage of wrong burner head * Drain tank water level monitor to prevent flashback |
|
Floppy disk drive |
Two 3.5 inch foppt" disk drives, 1MB/disk (when formatted) |
|
Auto-program functions |
Automatic analysis functions based on program of linked manual operations. |
|
Self-diagnostic functions |
Spectrometer wavelength error automatic seit diagnosis during D 2 lamp use. Automatic seif diagnosis of autosampler nozzle position (vial, rinse port, mixing port positions) |
GFA-6500 Graphite Furnace Atomizer
|
Heating temperature range |
Ambient to 3000° |
|
Heating control system |
Drying: Current control Ashing, atomizing: Temperature control |
|
Temperature program |
Stored on floppy disks together wich Main Unit AA Parameters. Number of programs unlimited. |
|
Heating stage |
20 steps |
|
Heating conditions |
1) Temperature: Ambient to 3000°C 2) Time: 0 to 1000 sec 3) Mode: RAMP/STEP 4) Inner gas: Types--2 live switching NORMAL (Ar) ALTERNATE (Dry air, N 2 , etc) Flow rateVariable in each stage 0 to 1.5L/min, 0,1L/min, steps Higher sensitivity is selectable in atomization stage. Pressure: 2.5 to 3.5kgf/cm 2 5) Outer gas: Flow rate--Fixed 1.5L/min Pressure: 2.5 to 3.5kgf/cm 2 |
|
Heating parameter settings |
Performed on the AA Main Unit. The following parameters may be set for each stage. 1) Temperature (°C) 2) Time (sec) - - Total for all stages is 2000 sec (max) 3) Gas type (NORMAUALTERNATE) 4) Higher sensitivity switch for innen gas control 5) Inner gas flow rate 6) Heating mode (RAMP, STEP) 7) Data sampling (ON/OFF) |
|
Temperature program display |
On AA Main Unit monitor 1) Table formal 2) Graph display 3) Program Status (countdown of remaining time) |
|
Temperature adjustment (Drying) |
1) Automatically alter each heating cycle. 2) Manually via keyboard at any time. |
|
Analyte accumulation for ultralow level analysis (Furnace) |
1 to 10 timen |
|
Safety features |
1) Cooling water pressure monitor 2) Gas pressure monitor 3) Over-current prevention mechanism 4) Furnace block Cooling check |
|
Graphite tube |
1) High-density tube 2) Pyrolytic tube Sample injection volume - - 50µL- (max) in 1µL increments |
|
Gas consumption |
3.0 L/min Argon (max) |
|
Cooling water |
1.0 L/min |
|
Power consumption |
6kW (max) (1ØAC, 200, 220, 230, or 240V, 50/60Hz) |
ASC-6000 Autosampler
|
Type |
2 syringe type autosampler |
|
Control |
RS-232C communication from AA Main Unit |
|
Functions |
1) Automatic rinse 2) Self diagnosis 3) Random access (all vial positions) |
|
Vial positions |
8 reagents (standards/modifiers) 60 samples |
|
Multielement sequential analysis |
12 groups/elements maximum |
|
Power requirements |
100, 120, 220, 240VAC (switch incorporated) 50/60Hz |
|
Dimensions |
Controller 154W x 423D x 264H (mm) Turntable 344W x 292D x 363H (mm) |
Continuous Sampling (Flame Mode)
|
Vials |
Reagent vial 60mL (30mm dia. X 105mm) Sample vial 19mL (16.5mm dia. X 105mm) |
|
Solvent vessel |
1 L capacity |
Microsampling (Flame)/Furnace Mode
|
, |
1) Standard preparation 2) Dilution 3) Matrix modification |
|
Vials Syringe |
Reagent vials 10mL beaker (30mm dia. x 40mm) Sample vials 2mL cup |
|
Syringe 1: 250µL Syringe 2: 2500µL |
|
|
Sample volume |
2µL to 200µL (0.5% RSD for 10µL volume)* |
|
Carryover |
Rinse port <10 -5 Mixing port < 10 -5 |
|
Rinsing |
Sample nozzle Mixing port Injection port |
|
Solvent vessel |
2L bottle |
|
Mixing |
0 Volume--0.6mL maximum 0 Number of reagents - - 4 in addition to the Standard for Calibratior and the Standard Addition Method. Automatic dilution/re-analysis of over ranged Samples - - Sample is diluted and dilution factor calculated. |
Optional Accessories
HVG-1 Hydride Vapor Generator
The hydride released by the decomposition of sodium borohydride reduces the elements in the sample to a vapor. The vapor is then heated and atomized in the absorption cell to allow high sensitivity measurement.
As, Se, Hg, Sn, Sb, Te, Bi, etc. may be determined.
The unique flush function eliminates caryover of high concentration samples.