Shimadzu GC 17 con in colonna iniettore (OCI) e FID. A / D converter SS 420x. Software CLASS-VP 4.2. Dongle per il controller GC. 2 x RS 232 Anno: 2001 confezione originale.
siehe Storeview
Maggiori Informazioni
Objektnummer B00011733
Seriennummer 011733
Nome oggetto Shimadzu 17
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Shimadzu        

Modell:                         GC-17A

Kommentar:     Dokumente dt.

Bedienerfreundlich und produktiv durch modernste Technik

40 Jahre Entwicklungserfahrung in der Gas­Chromatographie spiegeln sich wider im neuen GC-17A. Eigenschaften wie Benutzerfreund­lichkeit, hohe Präzision und Qualität, Flexibi­lität und Automatisierung verbindet er in idea­ler Weise miteinander.

Die flexible Injektor- und Detektor Modultech­nik erlaubt den Einsatz von bis zu 3 verschiede­nen Injektoren und bis zu 4 verschiedenen Detektoren auf einem GC-17A. Neben dein Standard-Split/Splitlos-Injektor stehen Wide­Bore, Gepackt-Säulen und ein temperaturpro­grammierbarer Injektor zur Verfügung. Dieser kann sowohl im On-Column-Modus als auch im PLV-Modus eingesetzt werden. Zur Detek­tion können FID, PND, ECD, FPD und WLD eingesetzt werden.

Dank der vollständig elektronischen Regelung (Advanced Flow Control) des Trägergases kann man sowohl die lineare Trägergasgeschwindig­keit (oder den Säulenfluss) als auch das Split­verhältnis direkt über die Tastatur eingeben. Detektorgasflüsse und der Septum-Purge-Fluss können ebenfalls elektronisch geregelt werden. Weitere Möglichkeiten mit der elektronischen Pneumatik:

• Druckprogrammierung zur Optimierung der Trennung bzw. Beschleunigung der Chroma­tographie

• Zeitprogrammierung des Splitverhältnisses zur Einsparung von Trägergas

• Splitlos-Druckpuls-Injektion zur Erhöhung des Probenaufgabevolumens

• Detektorgasprogrammierung zur Verbesse­rung der Detektorperformance

• Max. Säulenkopfdruck von 960 KPa und max. Fluss von 1200 ml/min zur Kompati­bilität mit schneller Chromatographie (Option)

• Atmosphärendruckkompensation zur Ver­besserung der Langzeitreproduzierbarkeit von Retentionszeiten.

Der GC-17A bietet eine Vielfalt von Kontroll­funktionen zur automatischen Systemvalidie­rung vor jeder Injektion an. So wird zusätzlich zur Säulenofentemperatur sowohl die Tempera­tur der benutzten Injektoren und Detektoren als auch der Säulenkopfdruck und der Gesamt­fluss zum Injektor überprüft. Bei dem FID (Wille-Range-Version) wird auch der Flam­menstatus kontrolliert. Sollte eine dieser Kon­trollen eine Abweichung vom Sollwert anzei­gen, wird der GC gestoppt. Diese und weitere Funktionen tragen zu einer hohen Qualität der analytischen Ergebnisse bei.

Alle Methodenparameter werden batteriege­puffert abgespeichert und können über einen Zahlencode geschützt werden. Dies garantiert die Durchführung von Analysen ohne die Möglichkeit zur Methodenmanipulation, was unerlässlich für eine GC-Analytik in Überein­stimmung mit GLP-Richtlinien ist.

Der Säulenofen besitzt die Maße 280 mm breit x 280 mm hoch x 180 mm tief. Der normale Temperaturbereich liegt zwischen +4°C und 450°C, optional bis

-90°C.

Es sind Temperaturprogramme mit bis zu 5 Heizraten möglich. Die maximalen linearen Heizraten betragen bis 200°C 40 ° C/min und bis 450°C 7 ° C/min.

Die Abkühlzeit von 300°C auf 50°C beträgt 6 min.

Gruppo prodotti: Gascromatografi Detector FID

Non è stato trovato alcun prodotto corrispondente alla selezione.