Seac Sirio S
Objektnummer | B00018156 |
---|---|
Seriennummer | 018156 |
Nome oggetto | Seac Sirio S |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Seac
model : Sirio S
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
GENERAL DESCRIPTION
The SIRIO Microplate Reader is an interferential filier photometer controlled by a microprocessor designed to measure the light absorbance (optical density) of samples placed on microplates of 96 wells.
The photometer is composed of an optical and a mechanical system managed by microcomputer that enables to obtain accurate and quick measurements.
The measurements can be carried out with single, dual or multiple wavelengths. The photometer has eight channels and the measurement takes place simultaneously for eight samples; the reading of the entire plate takes place in 3 seconds.
The start-up and the automatic self-test reduce any measurement error.
Detailed messages assure correct measurements and supply the user with correct indications.
All the programs and the data are permanently stored in non-volatile memories. lt is particularly useful for colorimetric, End Point and kinetic measurements and agglutination and turbidimetric applications.
The Reader can also be used together with other instruments in order to form a real automatic system. In particular with:
- Plate Washer
- Automatic plate dispenser/dilutor BRIO.
The Reader can also be used as a remote station controlled by a PC. In this case it is possible to carry out measurements of the Transmittance profile of the microplate 96 wells.
The Reader is equipped with a control system that verifies the presence of the Plate on the drive. When using the plates with microstrips, the Reader controls that there is at least one strip from the A channel to H or at least one column on the channel 1. This is useful when the Reader is connected to the Automatic Preparator BRIO, since it increases the automation level of the analysis procedures.
TECHNICAL FEATURES
Measurement range from -0.100 to +3.000 OD
Accuracy 2.5% at 0.150 O.D.
1.5% at 1.000 O.D.
1.5% at 2.500 O.D.
Precision +/- 1.5%
Linearity +/- 1% from 0 to 2.5 O.D.
Wavelength 400÷850 nm
Wavelength selection 4 narrow band interference filters.
Possibility to insert up to 8 filters
Light Source 20W halogen lamp
Reading time Single wavelength <3 sec.
Dual wavelength <10 sec.
Microplate mixing 3 speeds (0 ÷ 255 length)
Keyboard on-board membrane keyboard with
numerical and functional keys
Display 64x256 graphic LCD
Printer Graphic printer with 256 point
resolution per line and 20mm/s speed
Paper Thermosensitive, 112mm width
Data Storage 512Kbyte
Computer Interface RS232 Bi- directional
Clock function Day, Date, Time
Power supply 220V (110V an request) 50-60Hz
Power consumption 100VA
Fuse 110V : T 2.0A / 220V T 1.0A
Operating Conditions 10÷40 °C
Safety Standard 1010 Class I/Installation Group II
Weight 15 Kg
Size 48 x 38 x 23 h cm