Schott Titroline KF
| Objektnummer | B00018226 |
|---|---|
| Seriennummer | 018226 |
| Nome oggetto | Schott Titroline KF |
| Stato | Archived Product |
Gruppo prodotti: Titolatori (Karl-Fischer)
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Schott
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Karl-Fischer-Titrator
TitroLine KF
Mit dem
TitroLine KF
kann man bei der Wasserbestimmung nach Karl Fischer eigentlich nichts mehr falsch machen: Auf dem großen Display wird im Dialog jeder Arbeitsschritt angezeigt, der durchzuführen ist. Die vorparametrierten Methoden lassen sich bequem abrufen und erleichtern die Arbeit. Dazu kommt die Vielseitigkeit, die den TitroLine KF zu einem problemlosen KF-Messplatz für fast alle Bereiche der Industrie macht, wie z.B. für Pharma, Chemie, Lebensmittel- und Mineralölindustrie.
Der TitroLine KF hält folgende Methoden für Sie bereit: Probentitration, Titer Wasser, Titer flüssiger Standard, Titer Tartratdihydrat, Blindwert Ofen und Blindwert Lösungsmittel. Alle Methoden des TitroLine KF sind bereits mit den gebräuchlichen Parametern vorbelegt. Bei Bedarf können Sie die Parameter auch verändern.
Technische Daten
Dosiergenauigkeit systematische Messabweichung 0,1 %;
zufällige Messabweichung 0,05 %;
ermittelt nach EN ISO 8655-6
Anzeige
Matrix-LCD Anzeige 69 x 39 mm, 64 x128 Pixel mit
Hintergrundbeleuchtung, Kontrast einstellbar
Elektrode Anschluss für Doppelplatinelektrode, Ausgangsspannung 100 mV,
durch Software einstellbar zwischen 5...200 mV
Anschluss: 2 x 4 mm-Buchsen
Tastatur 5-polige DIN-Buchse für TZ 2825 und
PC-Tastaturen mit DIN-Stecker
RS-232-C- Schnittstellen
zwei bidirektionale RS-232-C Schnittstellen für PC/Drucker
und Waage/Geräte
Zylinder 20 ml aus DURAN® (Borosilikatglas 3.3)
Ventil Motor gesteuertes 3/2-Wegeventil aus PTFE / ETFE
Schläuche FEP mit UV-Schutz
Gehäuse Polypropyien und Polyflamm, 20 % Talkum
Frontfolie Polyester
Gehäuse-Abmessungen 310 x 265 x 205 mm (H x B xT)
mit Titrierstand TM KF und Titriergefäß,
310x135x205 mm(HxBxT)
Höhe inklusive Dosiereinheit (ohne Titrierstand)
Gewicht ca. 3,2 kg für komplettes Gerät mit Titrierstand;
ca. 2,1 kg für Grundgerät
Umgebungstemperatur: +10...+40 °C für Betrieb und Lagerung
Stromversorgung Netz: 230 V-, 50/60 Hz oder 115 V-; 50/60 Hz
Leistungsaufnahme 30 VA
Konformität EN 150 8655-3