Philips PU 9716/15

Seriennummer: 015465
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00015465
Seriennummer 015465
Nome oggetto Philips PU 9716/15
Stato Archived Product

Gruppo prodotti: Spettrometri Infrarosso

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Philips

model:                   PU 9716/15

annotation:           Dokumente engl.

 

Specifications:

Source                      lndirectly heated silicon carbide bar.

Optics                       Nominal Beam separation: l40mm

                                 Beam centre height: 56mm

Sample                      157mm wide x 327mm deep x l49mm high .

Compartment           Focus 38 .5mm from left-hand wall.

Monochromator         ‘Orthogonal‘ Ebert, focal length l80mm and aperture f/5.

                                 One grating 50mm x 50mm, 100 lines/mm and l400cm -1 first order            blaze. Grating used in first order from 2000 to 600cm -1 and in second   order from 4000 to 2000cm -1 . Unwanted orders removed by four                                  interference filters and one glass filter.

Detector                    Small area detector

Range (cm‘)              4000cm -1 to 600cm -1

Presentation              Strip chart 200mm wide. Scale change 2 :1, at2000cm -1 .

                                 Chart grid options:

                                 A4-l50mm x 280mm chart grid

                                 Standard-l50mm x 420mm chart grid

cm -1 Accuracy         Better than ±4cm -1 , 4000 to 2000cm -1 .

                                 Better than ±2cm -1 , 2000 to 600cm -1 .

cm -1 Repeat-             ±0.4cm -1 for 4000 to 2000cm -1 .

ability                         ±0.2cm -1 for 2000 to 600cm -1 .

Resolution                Spectral slitwidth on High resolution programme:

                                  1.5cm -1 at 1000cm -1

                                  3.0cm -1   at 3000cm -1

                                             and on High energy programme:

                                  3.5cm -1 at 1000cm -1

                                  7.0cm -1 at 3000cm -1

Photometric              As PU9706. `Spectraset`preset scan conditions facility

system                     

%T Linearity             Better than ±0.2%T as measured on the 1V output

%T Repeat-               Better than ±0.5%T as measured on

ability                         the 1V output

Output Sockets         0 - 1V - %T output + SP3-050 socket

Pen recorder             Dead band less than 0.3% of F.S.D.

                                 Agreement with 1V socket better than

                                 ±0.25%T

Transmittance           Continuously variable digital calibrated expansion of

expansion                  %T up to x 100

Back off                     Back off ± 150% T

Beam balance           ±1.5%T

Stray light                  Generally less than 0.3%

Scan times               1, 3, 7, 20 and 40 minutes and fast reset speed

Wavenumber           x 1 and x 5

expansion

Overall                       754mm wide x 627mm deep x 328mm high

dimensions

Weight                       47kg

Services                    110, 120, 200, 220 or 240V:200VA,

                                 50 or 60Hz, ±10% permissible range

Purging                      Not standard

ACCESSORIES

The following accessories may be used with the PU9700 Series instruments:

Purge Kit

This kit provides sealing of the covers, cell compartment lid and a heat sink for the heat from the source thus allowing dry air purging of the instruments. lt should be factory fitted as a optional extra to the PU9706, PU9716, PU9714 and PU9712 instruments.

SP3-060 Air Dryer

This unit supplies 40 litres/minute (1. 55 cu.ft/minute) of dry air at below —70°C dewpoint. The services required are:

(a)    Mains electrical supply of 115V or 230V (50 or 60Hz), 75VA.

(b)    Supply of compressed air at pressures between 4.2 and 8.4 kg/cm 2 (60 and 120 lb/in 2 ).

The Air Dryer is supplied complete with filters, gauges and controllers. Full details are given in the Instruction Booklet which accompanies the accessory.

lnfra-red Data Station

The PU9700 can be driven by the IR Data Station via the ACCESSORY port on the accessory interface panel at the rear right-hand side of the main instrument (Fig 1 .2). Full details are given in the manual which accompanies the accessory.

PU9702 Absorbance Accessory

The PU9702 Absorbance Accessory is used with the PU9700 Series of IR spectrophotometers to convert the recorder signal from transmission to absorbance in the range OA to 2A. lt is connected to the ACCESSORY socket on the Accessory Interface Panel. Full information is contained in the PU9702 Users Manual 9499 230 10711 that accompanies the accessory.