Soldé

Petrotest CFPP

Seriennummer: 018622
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Petrotest CFPP Cryostate 16-2357. 1 testglass. 2x complete tops for the CFPP measuring with pipette and thermometer. 4 testing sieves. Accessories to manual Pour point and Cloud point determination. YoC 2005. Device was 4 years for the analysis of biodiesel in use.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00018622
Seriennummer 018622
Nome oggetto Petrotest CFPP
Stato Archived Product

Gruppo prodotti: Termostati / Criostati

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Petrotest

model :                   CFPP

annotation :           Dokumente engl .

 

 

 

 

Description, Operating Conditions

 

KNF pumps in the range N 86 KN.18 and N 811KN.18 transfer, evacuate and compress 100 % oil-free. In operation they are gas-tight, and maintenance-free.

 

 

Electrical Equipment

  • See table 1 for fall electrical data
  • The protection class of standard versions is IP 20
  • The pumps are fitted with a thermal -switch to protect against over-loading.

 

 

Operating Conditions

  • Handling air, gases, and vapors at temperatures between + 5°C...+ 40°C
  • For maximum permissible operating pressure, ultimate vacuum, and flow capacity: see table 2. The pumps must not be used in areas where there is a danger of explosion
  • KNFN86KN18andN811K:18 pumps must not be used for liquids. You will find suitable liquid pumps in our Product Program
  • Before pumping a medium, the compatibility of materials of pump head, diaphragm and valves with the medium must be checked (for pump materials: see table 3).

 

If your potential application lies outside the above limits discuss it with our technical adviser

 

 

Ambient Condition

When the pumps are operating the following ambient conditions must be maintained:

  • Ambient temperature during Operation: between + 5° C .... + 40°C
  • During Operation an adequate supply of air for cooling must be provided
  • The pumps must not be used in areas where there is a danger of explosion.

 

 

 

Tables

 

Table 1: Electrical Data

 

N 86 KN.18

Electrical Type

-----------------------------------------------------------------------------------------------

Voltage                         230V                 100 V                115 V

Frequency                   50 Hz               50/60 Hz          60 Hz

Power consumption   65 W                70 W                60 W

Operating current        0.63 A               1.8 A                 1.2 A

Fuse                             1.0                    3.5                    3.2

(2x) T (A)

 

 

N 811 KN.18

Electrical Type

-----------------------------------------------------------------------------------------------

 

Voltage                         230V                 100V                 115 V

Frequency                   50 Hz               50/60 Hz          60 Hz

Power consumption    65 W                70 W                75 W

Operating current        0.8 A                 1.5 A                 1.3 A

Fuse                             1                       3.5                    3.2

(2x) T (A)

 

 

Table 2: Pneumatic Data

Pump Type                  Delivery (1/min*)         Ultimate vacuum         Maximum permis

( mbar abs)                  sible operating

pressure ( barg )

---------------------------------------------------------------------------------------------------------------------------

N 86 KN.18                  6                                  100                              2.4

N 86 KT.18                  5.5                                160                               2.5

N 811 KN.18                11.5                              240                               2

N 811 KT.18                11.5                              290                               2  

* Litre at STP at atm . pressure

 

 

Table 3: Pump Materials

Pump Type                  Material

Pump head                  Structured                    Valses

diaphragm

---------------------------------------------------------------------------------------------------------------------------

N 86 KN.18                  PPS                             EPDM                         FPM

N 86 KT.18                  PPS                             PTFE-coated               FFPM

N 811 KN.18                PPS                             EPDM                          FPM

N 811 KT.18                PPS                             PTFE-coated               FFPM

 

Material abbreviations according to DIN ISO 1629 and 1043.1

 

 

 

 

Technical Specifications of the device

 

Power supply:                         230 Vac ±10%, 50/60 Hz

Max. power consumption:       900W

Motors:                                     1/3 hp gas R404A

5/8 hp gas R404A

Operating range:                     ambient to -68°C

Precision:                                ±1°C

Dimensions:                            550x700x850 mm. (W x D x H)

Weight:                                    110 Kg.

Working temperature:                         0 to 35°C

Storage temperature:             -10 to 70°C

Ambient relative humidity:       lower than 90% rH not condensing

 

 

 

Part of labexchange logo