Archivio

PerSeptive Expedite 8909

Seriennummer: 016925
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00016925
Seriennummer 016925
Nome oggetto PerSeptive Expedite 8909
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       PerSeptive

model:                   Expedite 8909

annotation:           Dokumente engl.

ABI Expedite 8909 Oligo Synthesizer

The Expedite 8909 allows synthesis scale ranges from 50 nmol to 15 µmol for DNA oligonucleotides. This system allows preparation of phosphorothioates and enables preparation of peptide nucleic acid (PNA) molecules, which contain neutral "peptide-like" backbones with nucleobases. The 8909 comes with sequence and protocol editors, as well as software for creating customized reports. Each sequence run is documented, and data can be transferred from individual instruments to a central database.

Simultaneous Dual Column Synthesis

Alternating phase synthesis is the key to high throughput production. Each column is continuously synthesizing; there are no idle periods. As a result, cycle times are 3.5 minutes for both single and dual column synthesis.

With alternating phase synthesis, the two columns function essentially as independent units. You can start and stop an individual synthesis without influencing the progress of the other column. You can even run different scales and synthesis protocols simultaneously on the two columns.

Synthesis Scale

The Expedite 8909 allows synthesis scale ranges from 50 nmol to 15 µmol for DNA oligonucleotides. This system allows preparation of phosphorothioates and enables preparation of peptide nucleic acid (PNA) molecules, which contain neutral "peptide-like" backbones with nucleobases. The 8909 comes with sequence and protocol editors, as well as software for creating customized reports. Each sequence run is documented, and data can be transferred from individual instruments to a central database.

The Multiple Oligonucleotide Synthesis System (MOSS) can expand the capabilities of the Expedite system to allow the unattended synthesis of 16 oligonucleotides. The MOSS unit is placed on top of the 8909 system and requires no additional bench space. Trityl monitoring is available for all column positions.

MOSS Option

The Multiple Oligonucleotide Synthesis System (MOSS) Option, an extension to the Expedite™ 8909 System, enables unattended synthesis of 16 oligomers, saving time and increasing productivity. The in-line trityl monitor reads all 16 columns - if a chemistry failure occurs, the system will stop to minimize waste. To save bench space, the MOSS Option attaches to the top of the Expedite™ 8909 System.

After early roll-out problems the MOSS with the new valves works very well. The only draw back is that it does use a little more reagent because of the added tubing. The system is set them up so the customer can choose to use the MOSS or can choose to use the Expedite without the MOSS. This allows the flexibility of being able to use less reagent when they use the standalone Expedite or using the MOSS for over night runs and consuming a little more reagent (not a lot perhaps a 5% to 8% increase) but getting 16 oligos done over night without someone having to come in and load new oligos each time 2 are done.

50% Less Consumption

The Expedite™ System performs synthesis efficiently as well as quickly. The patented delivery system reduces monomer and reagent consumption by 50% over most systems available today. At 0.05, 0.2, and 1.0 µmol scales, less than 4.5 ml of reagents are consumed per cycle.

Trityl Monitor

The built-in trityl monitor, a standard feature on the 8909 model, contains a LED detector that reads the absorbance of the released dimethoxytrityl fractions to indicate the success of the synthesis - in real-time. If the absorbance falls below a pre-set value, the synthesis is put on hold.

Gas Depletion and Leak Checks

Prior to synthesis, systems are automatically checked for correct operation. Low pressure gas blankets reagent reservoirs to maintain an anhydrous environment, and high pressure gas actuates the injectors. The Expedite™ Systems check for leaks and adequate pressure to ensure that if the gas is depleted the synthesis is not affected.

The Report Generator prints synthesis-specific reports including synthesis conditions, trityl data, and runtime log.

Before every synthesis, the Expedite™ Systems calculate the volume of reagents required. Based on actual usage to date, the amount present in each reservoir is also calculated. You ca see the figures side by side to determine if you need to refill the bottles.

Expedite™ Workstation

- Set up and control synthesis on multiple systems
- Monitor synthesis remotely
- Store synthesis information on disk
- Import and export sequences from/to network connections
- Use the Sequence Editor to create, edit, and store DNA, RNA, and PNA sequences
- Generate detailed Reports for your lab or your customers, including sequence data, runtime synthesis log, trityl data, and operator notes
- Modify existing Protocols or create new ones by editing step order and durations. -- After editing, the protocol will be validated and any inconsistencies will be flagged.

Specifications

Controller: Internal microprocessor with LCD display (240 x 64 pixels); software on 3.5" floppy disk; parallel printer port; two serial RS-422 communications ports; uninterruptable power supply connection; 2 event outs, one event in

Monitors: High/low gas pressure and in-line trityl monitors with real-time feedback control to interrupt synthesis at safe point; pre-synthesis electronic sensor tests; user-settable alarms

Battery Back-up: Memory protect at power loss and auto-restart at power resumption

Diaphragm Pump Delivery: Pre-calibrated pumps with ceramic microfluidic plate

Reservoirs: Argon, helium, or nitrogen pressurized; 5 nucleotide vials (8905), 9 nucleotide vials (8909); 6 reagent reservoirs (8905), 8 reagent reservoirs (8909)

Reagent Capacity (0.05, 0.2, 1.0 µmol): 150 cycles (8905), 800 cycles (8909)

Reagent Consumption: Less than 4.5 ml (0.05, 0.2, and 1.0 µmol)

Safety Features: Vented to back with fan; separates chlorinated waste

Synthesis Mode: Alternating phase synthesis of two independent sequences; independent scales and protocols; independent stop and start

Cycle Times: 3.5 min cycles at 0.05, 0.2, 1.0 µmol scales regardless of number of columns running with standard DNA synthesis

Reagent Calculations: Volume required for synthesis; actual usage to date

User Files: 8 user files with 63 sequences in each file; protocols; alarm settings

Standard Chemistry: [beta]-cyanoethyl phosphoramidite; RNA; phosphorothioate (in-line sulfurization); mixed sites

Protocol Features: Immediate or safe-step interrupt; option to cleave or retain 5'-DMT group; calculates and/or displays sequence name, sequence, purine/pyrimidine ratio, molecular weight, theoretical O.D.'s; complete history log with all events

Workstation Software: Controls up to 6 instruments, 4 with M.O.S.S. option, complete protocol editing; sequence editor; expanded documentation and data storage

Gruppo prodotti: Sintesi DNA