Perkin Elmer Lambda 800
Objektnummer | B00016470 |
---|---|
Seriennummer | 016470 |
Nome oggetto | Perkin Elmer Lambda 800 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: Perkin Elmer
model: Lambda 800
annotation: Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Lambda 800
Key Features |
Unrivaled Benefits |
Wavelength Scanning t0 175 nm |
No additional option is required to scan below 185 nm (N 2 purging must be used) |
High Sensitivity PMT |
Gridless PMT design provides improved signal to noise in the UV region |
Standard Sample and Reference Beam Attenuators |
Included in basic instrument. No loss of sample compartment room. |
Standard RS232 Interface |
No computer compatibility problems |
Technical Description and Specifications Lambda 800
Principle |
Double beam, double monochromator, ratio recording UV/Vis spectrophotometer vvith microcomputer electronics, controlled by DELL PC or compatible Personal Computer. |
Optical System |
All reflecting optical system (SiO 2 coated) with holographic grating monochromator with 1440 Lines/mm UVNis blazed at 240 nm, Littrow mounting, sample thickness compensated detector optics. |
Beam Splitting System |
Chopper (46+ Hz, Cycle: Dark/Sampie/Dark/ Reference, Chopper Segment Signal Correction CSSC). |
Detector |
Photomultiplier R6872 for high energy in the whole UV/Vis wavelength range. |
Source |
Pre-aligned tungsten-halogen and deuterium. |
Wavelength Range(N 2 purge required below 185 nm) |
175 nm-900 nm |
UV/Vis Resolution |
< 0.05 nm |
Stray LightAt 200 nm (12 g/L KCI USP/DAP method) At 220 nm (10 g/L Nal ASTM method) At 340 nm (50 mg/L NaNO 2 ASTM method) At 370 nm (50 mg/L NaNO 2 ASTM method) |
> 2 A < 0.00008 %T < 0.00008 %T < 0.00008 %T
|
Wavelength Accuracy |
+/- 0.08 nm |
Wavelength ReproducibilityUV/Vis (Deuterium Lamp Lines) Standard deviation of 10 measurements UV/Vis
|
< 0.020 nm < 0.005 nm
|
Photometric AccuracyDouble Aperture Method 1 A Double Aperture Method 0.5 A N IST 1930D Filters 2 A NIST 930D Filters 1 A NIST 930D Filters 0.5 A K 2 Cr 2 0 7 -Solution USP/DAP method |
+/- 0.0006 A +/- 0.0003 A +/- 0.003 A +/- 0.003 A +/- 0.002 A +/- 0.010 A |
Photometric Linearity(Addition of filters UV/Vis at 546.1 -nm, Slit 2 nm, 1-sec. Integration Time) At 1.0 A At 2.0 A At 3.0 A |
+/-0.001A +/- 0.002 A +/- 0.006 A |
Photometric Reproducibility1 A wich NIST 930D Filter at 546.1-nm Standard Deviation for 10 measurements 0.5 A wich NIST 930D Filter at 546.1-nm Standard Deviation for 10 measurements 0.3 A wich NIST 930D Filter at 546.1-nm Standard Deviation for 10 measurements (2-nm Slit, 1 -sec. Integration) |
< 0.00016 A
< 0.00008 A
< 0.00008 A |
Photometric Range |
7 A (wich SRATT) |
Photometric Display |
Unlimited |
Bandpass |
0.05 nm-5.00 nm in 0.01 -nm increments UV/Vis range Fix resolution, constant energy or slit programming. |
Photometric Stability(After warm-up at 500 nm, 0 A, 2-nm Slit, 2-sec. Integration Time, Peak to Peak) |
< 0.0002 A/h |
Baseline Flatness(Lambda 900:190 nm-3100 nm, 2-nm Slit, Gain 1 NIR, 0.20-sec. UV/Vis-0,24-sec. NIR Integration Time, no smoothing applied) (Lambda 800: 190 nm-860 nm, 2-nm Slit, 0.20-sec. Integration Time, no smoothing applied) |
+/- 0.001 A |
Photometrie Noise RMS0A and 190 nm 0 A and 500 nm 2 A and 500 nm 4A and 500 nm 6 A and 500 nm (2-nm Slit, 1-sec.Integration Time, Gain 1 NIR) |
< 0.00010 A < 0.00005 A < 0.00020 A < 0.00100 A < 0.00500 A
|
Sample Compartment Instrument(W x D x H) |
200 mm x 300 mm x 220 mm |
PurgingOptics Sample Compartment |
YES YES |
Instrument Dimension (W x D x H) |
1020 mm x 630 mm x 300 mm |
Instrument Weight |
- 55 kg |
Digital 1/0 |
RS 232 C |
Light Beam |
90 mm above the base plate 120 mm beam separation 3 mm-12 mm beam height |
Instrument RequirementsPower Temperature Recommended Humidity |
90VAC-250VAC,50/60 Hz; 400VA 10°C-35,C 10-70% relative humidity, non-condensing |