Perkin Elmer Lambda 40
Objektnummer | B00013838 |
---|---|
Seriennummer | 013838 |
Nome oggetto | Perkin Elmer Lambda 40 |
Stato | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Das Lambda 20 und Lambda 40
Die UV/VIS-Spektrometer Lambda 20 und Lambda 40 können wahlweise als selbst-ständig arbeitende Grundgeräte mit Datenausgabe auf einem Drucker oder unter PC-Steuerung betrieben werden. Auch die stand-alone"-Version erfüllt mit ihrem Methodenkonzept alle Anforderungen moderner Routineanalytik.
Das Lambda 40 ist durch variablen Spalt (zwischen 0,5 nm und 4 nm) geeignet, sich wechselnd, anspruchsvolleren Anforderungen noch flexibler anzupassen.
Das Lambda 40 P ist eine Version des Lambda 40 mit zusätzlichem Vormonochromator, der fas Falschlicht des Gerätes noch einmal reduziert.
Übersichtliche Bedienung
Wenige Bedienungstasten reichen aus, um mit dem Spektrometer zu arbeiten. Zusätzlich ist jede Funktion mit einem deutschsprachigen Hilfe-Text hinterlegt, der dargestellt oder ausgedruckt werden kann.
Auch in der Bedienung ist der Benutzer immer auf dem Laufenden: Während der Messung zeigt das Gerät Wellenlänge und Viehwert, während der Methodendefinition werden alle verfügbaren Optionen kontinuierlich dargestellt.
Für schnelle Messungen stehen die GOTO Lambda- und Background-Taste zur Verfiigung, mit denen der Mefawert einer Probe direkt gemessen und ausgedruckt werden kann.
Typische Spezifikationen
Lambda 40
Prinzip Registrierendes UVNIS-Spektrometer mit Mikrocomputer-Elektronik, Keyboardeingabe, Fluoreszenzanzeige und optioneller PC-Steuerung.
Optik Zweistrahl-Spektrometer mit holographischem Konkavgitter mit 1053 lines/mm.
Strahlungsquellen Deuterium- und Wolfram-Halogenlampen, vorjustiert, automatischer Lampenwechsel.
Wellenlängenbereich 190-1100 nm
Falschlicht 0,01 %T bei 220, 340, 370 nm (0,005 %T, Lambda 40 Vormonochromator)
Wellenlängenrichtigkeit ± 0,1 nm am D 2 -Peak 656,1 nm
Wellenlängenreproduzierbarkeit ± 0,05 nm am D 2 -Peak 656,1 nm
Spektrale Bandbreite 0,5, 1, 2 und 4 nm variabel
Photometrische Richtigkeit ± 0,003 A bei 1 A, gemessen mit NIST 930 Filter
Photometrische Reproduzierbarkeit ± 0,001 A bei 1 A
Stabilität 0,00015 A/h (bei 500 nm, 2 s Response, nach Einlaufzeit)
Abweichung von der Basislinie 0,0005 A, 2 nm Spalt
(200-1100 nm bei 0 A, smooth 2, 240 nm/min)
Rauschen 0,00003 A (0 A, 500 nm, 2 s Response), RMS
Registriergeschwindigkeit 7,5 bis 2880 nm/min
Anzeigebereich -4 A bis 4 A
Datenausgang RS 232C/V24, Centronics Parallel-Druckerschnittstelle und Zubehör-Kontrolle. Zweite RS232N24 wahlweise.
Anzeigenfeld zweizeilige, 20stellige Vakuumfluoreszenzanzeige, Folientastatur
Stromversorgung 100 bis 250 V, 50/60 Hz, 260 W
Umgebungstemperatur + 15°C to + 35°C
Abmessungen 650 mm breit, 233 mm hoch, 56 mm tief
Gewicht ca. 26 kg