Perkin Elmer Lambda 14
| Objektnummer | B00007777 |
|---|---|
| Seriennummer | 007777 |
| Nome oggetto | Perkin Elmer Lambda 14 |
| Stato | Archived Product |
Gruppo prodotti: Fotometri / Spettrofotometri
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Lambda 14 is a versatile spectrometer operating in the ultraviolet (UV) and visible (
Lambda 14 is usable in a wide range of applications as indicated by its performance specifications.

Technical Data
General
Type Scanning double-beam spectrometer for the UV/Vis range; with microprocessor and keyboard.
Dimensions Width: 650 mm
Height: 233 mm
Depth: 560 mm
Mass 26.4 kg approx.
Power requirements 100 V to 240 V AC, 50/60 Hz; 300 VA
Ambient operating 15° C to 35° C
temperature
Humidity range 20% to 80% relative humidity without condensation
Technical Standard In compliance with the requirements for technical instruments stipulated by IEC 1010-1/9.90.
Radio interference In compliance with the legal requirements of
suppression the FRG (VDE 0871 grade B)
Optics
Beam center height 15 mm above cell holder bottom.
Beam Cross-section 0.5 nm slit ca. 0.25 mm x 7 mm
( width x height)
1 nm slit ca. 0.5 mm x 7.5 mm
( width x height),
2 nm slit ca. 1 mm x 7.5 mm
( width x height),
4 nm slit ca. 2 mm x 7.5 mm
( width x height),
at focal point of sample and reference beam in sample compartment.
Optical pathlength in 121 mm
sample compartment
Grating Holographic concave grating with
(Monochromator) 1053 lines/mm in the center.
Radiation sources Prealigned deuterium and halogen lamps.
Detector Photodiodes
(One for the sample beam and one for the reference beam)
Abscissa
Wavelength range 190 nm to 1100 nm
Wavelength accuracy + 0.3 nm
Wavelength 0.1 nm reproducibility
Spectral bandwidth 0.5 nm, 1 nm, 2 nm, 4 nm (selectable fixed slit widths) Lamp change automatically at 326 nm
Scan speeds 7.5, 15, 30, 60, 120, 240, 480, 960, 1920 and 2880 nm/min
Ordinate
Photometric range Transmission 0% to 100%
Absorbance -6.000 to 6.000 (Display range)
1 to 9999 (concentration units)
Photometric accuracy Absorbance ± 0.003
( measured at Absorbance = 1, at 440 nm, 546.1 nm and 635 nm with NIST 930 filters)
Absorbance ± 0.015
( measured at Absorbance = 1, at 257 nm and 350 nm with potassium dichromate solution)
Stray radiation Transmission < 0.02%
( at 220 nm, 340 nm and 370 nm)
Absorbance > 2
( measured at 200 nm with potassium chloride solution against distilled water)
Baseline linearity 2 nm slit: Absorbance ± 0.0005
( corrected ; 200 nm to 1100 nm, scan speed 240 nm/min, smooth 2)
Baseline noise 2 nm slit:
Absorbance < 0.00006 RMS,
Absorbance < 0.0002 peak-to-peak
(3 min at Absorbance = 0, wavelength 500 nm and response 2 s)
Baseline stability Absorbance < 0.0003 per hour
( drift ) (500 nm, after warmup)
Data Output
Digital port One RS 232 C interface (serial), for connecting a printer or PC; optional second RS 232 C interface.
Display Information, parameters and entries are shown on a two line vacuum fluorescence display with 20 alphanumeric characters per line.
Methods
Types Time drive, Scan, Wavelength Program, Concentration 1 and Concentration 2 Analysis with factor and with Calibration, Oligoquant 1, Oligoquant 2, Enzyme Kinetics, Substrate Kinetics.