Archivio

Perkin Elmer GeneAmp 9600

Seriennummer: 012039
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00012039
Seriennummer 012039
Nome oggetto Perkin Elmer GeneAmp 9600
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Perkin Elmer

model :                   GeneAmp 9600

annotation :           Dokumente engl.

 

 

 

The GeneAmp® PCR System 9600 is an auto­mated instrument, specifically designed for control­ling the times and temperatures required by the GeneAmp Polymerase Chain Reaction (PCR) process for nucleic acid amplification. The GeneAmp PCR System 9600 consists of a 96-well position aluminum sample block, which is heated by a film heater and cooled by an internal refrigeration unit. User interface is through a full numeric keypad with heating and cooling indicator lights and information viewed an a 2x20 character fluorescent display. An optional printer can be attached through the RS232C interface and hard copy of the programmed protocols and achieved times/temperatures can be obtained.

 

GENEAMP PCR SYSTEM 9600 FEATURES

Samples and temperatures

Sample Capacity: Up to 96, 0.2-mL MicroAmp® PCR Reaction Tubes

Textfeld: Internal Memory. 150 user files
Modifiable Programs. Modifiable HOLD program for maintaining a specific temperature for either an indefinite or fixed time period. Modifiable CYCL program contains the pattern of thermal ramp and hold segments for PCR cycling. Contains up to eine setpoints, each of which com¬prises a ramp segment and a hold segment for the specific target temperature. The pattern can be repeated up to 99 times.
AUTO program allows the user to automatically increment or decrement the setpoint times and temperatures by a fixed amount every cycle.
User Diagnostics. Ability to run a number of diagnostic routines to verify heating and cooling rates, overshoot and undershoot temperatures, and check display functions.
Temperature Range: 4.0-99.9°C

Temperature Display: Calculated sample tem­peratures displayed and setable to 0.1°C

Heating/Cooling Rates : Average heating and cooling rate of 1 °C/second for the sample

Static Sample Temperature Uniformity: ± 0.5°C, 30 seconds after clock start, over the range 35-100°C

Temperature Accuracy: ± 0.75°C over the range 35-100°C

Temperature Calibration: The GeneAmp PCR System 9600 is calibrated to standards traceable to the NIST (National Institute for Standards and Technology, U.S.).

 

Software

Internal Memory. 150 user files

Modifiable Programs . Modifiable HOLD program for maintaining a specific temperature for either an indefinite or fixed time period. Modifiable CYCL program contains the pattern of thermal ramp and hold segments for PCR cycling. Contains up to nine setpoints, each of which com-prises a ramp segment and a hold segment for the specific target temperature. The pattern can be repeated up to 99 times.

AUTO program allows the user to automatically increment or decrement the setpoint times and temperatures by a fixed amount every cycle.

User Diagnostics . Ability to run a number of diagnostic routines to verify heating and cooling rates, overshoot and undershoot temperatures, and check display functions.

 

PCR Performance Guarantee

Using the GeneAmp PCR System 9600 and the GeneAmp® PCR Reagent Kit, an amplification yield of at least 100,000 fold of the Lambda Control DNA target can be achieved with:

Ø       0.2 µM each of the Lambda Control Primers

o         0.1 ng of Lambda Control DNA target

Ø       50-µL reaction volume without a mineral oil overlay in a 0.2-mL MicroAmp® Reaction Tube

Ø       25 thermal cycles: 94°C for 15 seconds, 68°C for 60 seconds.

 

Dimensions

Width: 52 cm (20 in.)

Depth: 61 cm (24 in.)

Height: 30.5 cm (12 in.)

Weight: 40.5 kg (90 lb)

 

Power

Part Number    Voltage             Frequency

N801-0001       120 VAC          60 Hz

N801-0002       230-240 VAC   50 Hz

N801-0003       100 VAC          5 0/60 Hz

 

Gruppo prodotti: PCR

Non è stato trovato alcun prodotto corrispondente alla selezione.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure