Soldé

Perkin Elmer GC-IR 2000

Seriennummer: 010060
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Perkin Elmer interfaccia GC-IR 2000. Per l'accoppiamento del sistema FTIR spettrometro GC PE 2000. Nuovo prezzo: 25.600, - Euro.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00010060
Seriennummer 010060
Nome oggetto Perkin Elmer GC-IR 2000
Stato Archived Product

Gruppo prodotti: GC Accessori diversi

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Perkin Elmer

Modell:            GC-IR 2000

Kommentar:   Dokumente engl.

Introduction

The System 2000 GC-IR Interface is used to obtain infrared spectra of the components that elute from a gas chromatograph (GC). Identification of the peaks in a chromatogram can be achieved by inspecting the infrared spectrum of each of the peaks. The end of the GC column passes through the heated transfer line to an infrared transmitting cell (light pipe). The eluate from the GC passes from the end of the column, into the light-pipe, and then returns to the GC through an inert, glass-lined return line (Figure 1-1). Both the transfer line and the glass-lined return line are enclosed in the heated transfer block that connects the GC to the Interface.

Schematic Diagram of the Gas Flow Within the GC-IR Interface

   Column

   Heated Transfer Line

   Heated Glass-Lined Return Line

   Flow Restrictor

   Make-up Gas Connector

       (At the rear of the instrument)

   Infrared Transmitting Window

   Heated Light-pipe

       Direction of Gas Flow

The temperature of the light-pipe and transfer line is thermostatically controlled and is set using the Time Resolved Infrared (TR-IR) software.

Rear Panel of the GC-IR Interface

View of the GC-IR Interface with its Cover Removed


Input Mirror

Hole for Bolt

Plugged Hole (Used in Forward Configuration)

Oven Cover Fixing Screw

Electrical Connector

Detector

Screw Position for Fixing Cover

Baffle

Purge Outlet

Indicator Panel Connection

Output Mirror from Light-pipe

Make Up Gas Inlet

Transfer Line Input

Transfer Line Output

Oven Cover

Input Mirror to Light-pipe

Electrical Connection Block

Shielded Electronics


Part of labexchange logo