Perkin Elmer AAnalyst 400
| Objektnummer | B00018612 |
|---|---|
| Seriennummer | 018612 |
| Nome oggetto | Perkin Elmer AAnalyst 400 |
| Stato | Archived Product |
Gruppo prodotti: Assorbimento Atomico (Fiamma e Grafite)
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Perkin Elmer
model : AAnalyst 400
annotation : Dokumente engl .

Control and Data System
User Interface
Complete PC control of all functions of the AAnalyst TM 400 using WinLab32 TM for AA software. WinLab32 for AA includes an innovative user interface that makes the software easy to learn and use, including a clear graphical design, task-oriented organization of the windows, an understandable vocabulary, extensive tool tips in multiple languages, simple data displays and Wizards for the simplification of many tasks.
WinLab32 is fully multitasking, allowing the analyst to report analytical results, view data or add priority samples without interrupting the analysis in progress.
Using WinLab32 software, setup is flexible and easy. Standard operating conditions for flame, graphite furnace and FIAS techniques are included. Auto Analysis Control links methods for each technique with a sample-information file. The sample list can be created by third-party software or LIMS and downloaded to the system.
WinLab32 software provides many tools to increase lab productivity. With WinLab32 Offline, method and sample-information files can be created and data reviewed or reprocessed without interrupting the current analysis.
WinLab32 software provides extensive QC protocols to meet internal and regulatory requirements. Data Reprocessing allows changes to many method and sample-information parameters after data collection and the recalculation of the results using the new parameters. With Data Reprocessing, the raw data are never altered, thereby ensuring data integrity is maintained.
WinLab32 Reporter provides the ability to generate post-run reports in a variety of formats. The Export feature of Data Manager can be used to export results as comma-delimited ASCII files for compatibility with commercial third-party programs such as Microsoft ® Excel ® , Access ® and Word.
21 CFR Part 11
An optional WinLab32 Enhanced Security TM package is available for labs needing to be compliant with 21 CFR Part 11 regulations.
Hardware
System
True double-beam echelle optical system. Front surfaced, reflecting optics with protective coating. Deuterium background corrector and two built-in EDL power supplies.
Optical System
Echelle monochromator . Focal length: 300 mm. Grating : 36 x 185 mm area, 79 lines/mm, blaze angle 76˚. Fused-quartz prism: 95 x 40 mm, 60°. Wavelength: 189-900 nm. Spectral bandpass : 0.15 nm at 200 nm. Reciprocal linear dispersion: 2.4 nm/mm . The photometer optics are covered to protect against dust and corrosive vapors. For maximum protection, the optical system can be purged with an inert gas.
Detector
High-efficiency, segmented solid-state detector.
Light Sources
Hollow cathode or electrodeless discharge lamps ( EDLs ). EDLs provide much higher light output and longer lifetime when compared to conventional hollow cathode lamps. Lamp elements, recommended operating currents and slit selection are automatically recognized and set when using PerkinElmer ® Lumina TM series AA lamps. Lamp alignment is completely automatic with the four-lamp turret.
E-box
All electronics are located in a single user-replaceable module that the operator can easily replace without requiring a service visit.
Gas Controls and Burner System
Flame Gas
Fully automated gas box with computer-controlled oxidant selection, automatic gas sequencing, oxidant and fuel monitoring and control.
Control
Software-actuated ignition with air/acetylene. Acetylene flow is automatically adjusted when switching to or from nitrous-oxide/acetylene operation.
Flame Safety Features
Fully interlocked operation prevents ignition if the proper burner head, the nebulizer , end cap or burner drain system are not correctly installed, the level of the liquid in the drain vessel is incorrect, or gas pressures are too low. Interlocks will automatically shut down the gases if a flame is not detected. The flame is automatically and safely extinguished in the event of a power failure or when the emergency flame-off button is used.
Burner System
An inert-polymer mixing chamber provides superior analysis of corrosive and high-solid matrices. The spray chamber is manufactured from a high-strength composite, eliminating the need for pressure-relief devices. The high-precision inert nebulizer maximizes stability and sensitivity. A 10-cm single-slot solid titanium burner head for air/acetylene operation is included. Optional burner heads include: 5-cm nitrous-oxide/acetylene, 10-cm three-slot air/acetylene and 5-cm single-slot air/acetylene.
Sample Area
25 cm wide x 25 cm deep sample compartment for easy access to burner components.
Accessories for the AAnalyst 400
Autosamplers
Flame autosamplers automate standard and sample introductions for instrument calibration and sample analysis, extending the spectrometers capabilities to those of a fully automated analytical workstation.
Sample Dilution
The AutoPrep 50 sample-dilution system provides an optimized tool for truly automated flame AA. With automatic, intelligent on-line dilution capabilities, the AutoPrep 50 eliminates the time-consuming, manual, error-prone portion of your flame AA analyses.
Mercury/Hydride System
For the analysis of mercury or hydride-forming elements, an optional automated flow injection system or a manual mercury/hydride System can be added. Flow Injection Atomic Spectroscopy (FIAS) combines the advantages of mercury/hydride AA with those of the flow injection, enabling mercury/hydride AA procedures to be truly automated.
System Specifications
Dimensions
70 x 65 (0.46 m 2 ) x 65 cm (W x D x H)
Weight
49 kg
Power
100-230 V (±1 0%), 50/60 Hz (±1 %), 300 VA (maximum)
Technical
Classified as a laboratory instrument.
Complies with the applicable European Union directives and standards for safety and electromagnetic compatibility for CE Marking, the safety requirements for
Environmental
Dust-free, free of vibrations, ambient temperatures: +15 ˚C to +35 ˚C with a change rate of a maximum 3 ˚C per hour. Relative humidity: 20% to 80% non-condensing.