Soldé

Olympus PK 7100

Seriennummer: 010097
Status: Archived Product
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Descrizione:
Olympus gruppi sanguigni Analyzer PK 7100. Prezzo originale: 306 775, - Euro.
Quotation
siehe Storeview
Maggiori Informazioni
Objektnummer B00010097
Seriennummer 010097
Nome oggetto Olympus PK 7100
Stato Archived Product

Gruppo prodotti: Ematologia

Non è stato trovato alcun prodotto corrispondente alla selezione.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Olympus

Modell:            PK 7100

Kommentar:   Dokumente dt.

ANALYZERSPEZIFIKATIONEN

1. Gerätename                        OLYMPUS PK7100

2. Analysemethode                 Mikrotiter-Methode

3. Anzahl der Kanäle               12 Kanäle

                                               max. 10 Kanäle für Erythrozyten

                                               max. 12 Kanäle für Plasma

4. Probendurchsatz                240 Proben/Stunde

5. Reaktionszeit                      Wählbar zwischen 60 und 30 Minuten

6. Proben                                 Plasma und Erythrozyten

7. Probengefäß                       Glas- oder Kunststoffröhrchen

                                               12mm Durchmesser, 100mm hoch

                                               15mm Durchmesser, 75mm hoch

8. Probenrack                          10 Proben/Rack

                                               Weiß    für Routine-Proben

                                               Gelb     für Gruppen-Nummer

                                               Grün     für Qualitäts-Kontrollen

                                               Schwarz für Service-Tests

9. Probenidenfikation               Automatische Bar-code Leseeinheit (7 digits)

10. Probendetektion                Plasma- und Zellerkennung durch Elektroden

11. Probenpipettierung            Mikrospritzen-Pipettierung

                                               Zellvolumen               10 - 30 µl

                                               Plasmavolumen        10 - 250 µl

                                               Gesamtmenge          500 µl

                                               Schrittweite               1 µl

12. Verdünnungspipettierung Spritzen-Pipettierung

                                               Verdünnung für Zellen 1000 µl

                                               Verdünnung für Plasma 250 - 1000 µl

                                               Justierung durch Stroke pins

13. Verdünnte Proben Pipettierung    Mikrospritzen-Pipettierung

                                               Volumen pro Kanal     10 - 40 µl

                                               Schrittweite     1 µl

14. Reagenzbehälter               Kapazität: 15 ml für ca. 500 Proben

                                               Ausgestattet mit Mischer.

15. Reagenzpipettierung         Mikrospritzen-Pipettierung

                                               Volumeneinstellung durch Stroke pins 10, 15, 25, 35 µl

16. Reaktionsbehälter             OLYMPUS Mikrotiterplatte

                                               Abmessung : 92 x 130 x 12 mm

                                               Kapazität : 10 x 12 Kanäle

17. Photometrie                       Scanner Photometer

18. Entscheidungsmethode    Automatische Erfassung der Peripher/Central Intensität und         Ausgabe nach Programm im Datenprozessor.

                                               Visuelle Betrachtung.

19. Wasserzufuhr                   Automatische Wasserzufuhr von deionisiertem Wasser    Verbrauch: 151/Stunde

20. Abfluß                                Automatische Abwasserpumpe

21. Drucker                             80 Zeichen Matrix mit parallel Interface

22. Datenausdruck                  1. Analysedatum            6. Analyseart

                                               2. Kanalentscheidung    7. Photometrische Daten

                                               3. Probennummer         8. Resultat

                                               4. Gruppennummer       9. Marker

                                               5. ID-Nummer

23. Alarme                               1. Rackstau                   4. Wassermangel

                                               2. Plattenstau                 5. Mechanische Probleme

                                               3. Papierende

DATENPROZESSOR-SPEZIFIKATIONEN

1. Computer                            Intel 8088 CPU mit 256KB RAM

2. Tastatur                               ASCII Zeichen und Spezialfunktionen

3. Bildschirm                           Monochrom grün, 12 Zoll, 80 Zeichen x 24 Zeilen

4. Speicher                              8 Zoll Floppy, Double sided, Double density 256 byte/sector

                                               Kapazität: 3822 Proben

5. Drucker                               132 Zeichen Matrix mit parallel Interface 200 Zeichen/Sekunde

6. Ersteingaben                       Datum, Bedienername

7. Analytische Parameter        5 verschiedene Parameter Files können erstellt werden.

8. Manuelle Eingaben              Die Daten können manuell korrigiert und ergänzt werden.

9. Datenauswertung                Die Daten können nach verschiedenen Kriterien ausge­wertet       werden.

10. Datenausgabe                   Die Daten können nach verschiedenen Kriterien ausgedruckt       und übertragen werden.

11. Option                                Alarmanzeige Diagnosefunktionen

ALLGEMEINE SPEZIFIKATIONEN

1. Densitometer                      Einstellung von Zellsuspensionen

                                               Meßbereich 1 - 2 %

                                               Anzeige 3stellig

2. Raumbedingungen              Temperatur zwischen 18 - 30°C

                                               Rel. Feuchte zwischen 40 - 80%

3. Elektrische Versorgung       Analyzer/Datenprozessor:    220V, 50 Hz, 3 kVA

                                               Densitometer:                       220V, 50 Hz, 0.1 kVA

4. Abmessungen                     Analyzer:                               1500 (B) x 750 (T) x 1400 (H)

                                               Datenprozessor                    620 (B) x 760 (T) x 1030 (H)

                                               Drucker                                 630 (B) x 860 (T) x 900 (H)

5. Gewichte                             Analyzer                                450 kg

                                               Datenprozessor                    105 kg

                                               Drucker                                 45 kg

Part of labexchange logo
Search engine powered by ElasticSuite