Archivio

OA-SYS N-EVAP 116

Seriennummer: 016812
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00016812
Seriennummer 016812
Nome oggetto OA-SYS N-EVAP 116
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                   OA-SYS

Modell:                N-EVAP 116

Kommentar:        Dokumente deut.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Introduction N-EVAP Models

The instrument consists of a base and stand assembly, sample holder and gas distribution system. Test tubes are held in place by a spring-loaded sample holder and support tray. Each position is numbered. The gas at 5 to 10 psig passes through an adjustable flow meter to the distribution manifold. Flexible tubing leads to valve-tube assemblies at each position. Depending on the test-tube size and solvent volume they can be individually raised or lowered to the correct height. Needles or glass pipets blow gas onto the surface of the solution resulting in rapid evaporation of the solvent. All materials used are laboratory quality and can withstand contact with organic solvents. Acid resistant models are available for corrosive applications.
The round, stainless steel water bath is thermostatically controlled and will accurately maintain water temperature from 30° to 70° C. Optional dry baths filled with glass or aluminum beads will operate from 30° to 130° C. A high temperature limit switch is installed for safety. An electrical GFCI plug is optional. An intrinsically safe, purged case is also available as an option. The bath is UL/CUL approved for laboratory use.

N-EVAP Features

·                     Five models available in 6, 12, 24, 34 and 45 positions.

·                      Compact size takes minimal hood space.

·                      Water bath provides gentle heat.

·                      Circular stand turns so each sample is accessible from the front.

·                      The larger models have a band spring hoist assembly for easy raising or lowering into the bash. Accommodates samples in test tubes 10 to 29 mm diameter. Volumes from 1 ml to 50 ml.

·                      A gas flow meter with valve, controls and indicates gas consumption.

·                      A needle valve adjusts gas flow at each position.

·                      Stainless steel 4 inches x 19-gauge needles standard.

·                      All metal parts are made of stainless steel, nickel chromed brass or anodized aluminum. Plastic parts are laboratory grade and will withstand contact with common organic solvents

N-EVAP Nitrogen Evaporator Specifications

Number of Sample Positions

34

45

Instrument Catalog Number

11634

11645

Overall Dimensions
w x d x h

24 x 19 x 34 in
61 x 48 x 86 cm

Sample Holder and
Gas Manifold Layout

Circular Single Ring

Circular Dual Rings

Test Tubes Accommodated
Diameter mm

10-29 mm

Outer Circle
10-19 mm
Inner Circle
10-30 mm

Side Mount Function Control Box
with Timer for Nitrogen & Heat

Standard

Gas Flow Meter
Liters/Minute

0-20 lpm

Gas Pressure Regulator
Range

Standard
0-30 psig

Stainless Steel Needles
Length & Gauge

4in x 19ga
10cm x 19ga

Hoist Assembly
(water bath models only)

Dual Band Springs

Rotating Gas Supply Tube

Standard

Instrument Standard Features

Instrument Options

Gas Injector Options

Instrument rotates. All samples accessibly from front.
Gas flow meter & valve measures & controls flow rate.
Gas needle valve at each sample position.
Certified phthalate free tubing.
Laboratory grade materials stand up to organic solvents.

Acid resistant coating (-RT) or (-RP)
Dry bath replaces water bath (-DA)
Instrument only, delete heating unit (-0)

FEP coated needles (-T)
6 inch long needles (-6)
Pasteur pipette fittings (-P)

Gas Injector Accessory
Pasteur pipette adapters # NA0636

OA-SYS Heating Device Specifications

Model Number

5085

8125

14165-C

Inside Dimensions
Diameter & Depth

8.5 x 4.5 in
21.6 x 11.4 cm

12.0 x 4.5 in
30.5 x 11.4 cm

16.0 x 4.5 in
40.6 x 11.4 cm

Outside Dimensions
w x d x h

13 x 12 x 7 in
33 x 30 x 18 cm

18 x 16 x 7 in
46 x 41 x 18 cm

24 x 19 x 15 in
61 x 48 x 15 cm

Heaters Total Watts

500 W

800 W

1400 W

Temperature Controller Type
and
Accuracy

Mechanical Thermostat
± 2 C

Mechanical Thermostat
± 2 C

Digital Electronic
with LED Display
± .5 C

Heating Device Standard Features

Heating Device Options

Stainless steel construction.
Water bath temperature range 30 - 90 C.
Dry bath temperature range 30 - 90 C.
Stepped bath rim helps contain water or dry media.
High temperature protection switch with automatic reset.

Intrinsically safe Z purged bath (-Z).
Intrinsically safe active type Z purged bath (-ZX).
Acid resistant coating (-R)
Digital electronic temperature control (-E on model 5085, 8125)

Heating Device Accessory
GFCI electrical adapter, in-line #BP0409 (110 volt only).

Gruppo prodotti: Miscellanea per Laboratorio

Non è stato trovato alcun prodotto corrispondente alla selezione.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure