Archivio

Minolta CR 310

Seriennummer: 014949
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00014949
Seriennummer 014949
Nome oggetto Minolta CR 310
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Firma:                Minolta

Modell:              CR 310

Kommentar:      Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

CR-310

Introduction

Konica Minolta CR series Chroma Meters are compact, lightweight, portable tristimulus colorimeters for measuring reflected color and color difference in a wide range of industrial fields. Five different CR-300 series models are available to meet the needs of various applications.  All CR-300 series models offer improved inter-instrument agreement to allow multiple units to be used for color control both within a company and between companies.

The Chroma Meter CR-310 offers ø50mm measuring area and wide-area illumination/0° viewing geometry for measurements of textured surfaces

Features

Illuminating/viewing system

The normal head of the CR-310 averages the measurement over a relatively large area.  This is especially useful when measuring textured samples, such as carpet or cloth, which might result in measurement errors if a smaller specimen area were used.  A pulsed xenon arc(PXA) lamp inside a mixing chamber provides diffuse, uniform lighting over the 50mm diameter area.  Only the light reflected perpendicular to the specimen surface is collected by the optical-fiber cable for color-analysis. 

·                      Since measurements made with this system are greatly influenced by specular reflection, this system should not be used for measuring glossy surfaces.

CR-310

Color-Control Applications

Textile/dyeing industry:

Dyed cloth or fibers; rugs, carpets, drapes, etc.

Agriculture :

Color analysis of soil.

Food industry

Processed foods; determining maturity level of raw products.

Data Processor(DP-301) Features

Full portability for On-the-Go Color Control

Each CR-300 series Chroma Meter consists of a lightweight, handheld measuring head and a compact, battery-operable data-processor.  The whole system is fully portable and can be used wherever the measurement subject is, indoors or outdoors, for on-the-spot color control

Variety of Data-Processing Functions

The data processor of the CR-300 series Chroma Meters is an all-in-one unit with an LCD display, thermal printer, and RS-232C, remote-control, and Δ E*ab alarm terminals.

Data can be displayed, printed out, or output in a variety of color systems.

To provide the highest measurement accuracy, the data processor is equipped with a multicalibration function, which utilizes all calibration data in memory (calibration data can be stored in up to 20 memory channels) in calculating the measurement data.  Users can also select a single calibration memory channel if desired.

Other features of the data processor include: Memory space for 300 sets of measurement data; 20 memory channels for target data for color difference measurements; statistical calculations; an interval timer for automatic, timer-controlled measurements; and a Δ E*ab alarm function. 

Measuring Head Specifications

Receptors

6 silicon photocells (3 to measure source illumination, 3 to measure reflected light) filtered to detect primary stimulus values for red, green, and blue light

Spectral response

Closely matches CIE 1931 Standard Observer curves

Light Source

Pulsed xenon lamp

Illumination/measurement system

Wide-area illumination/
0° viewing angle
(specular component included)

Measuring area

50mm

Short-term repeatability

Chromaticity (x, y): Within 0.0002
Color difference
Δ (E* ab): Standard deviation within 0.07
(Measurement conditions: White calibration plate measured 30 times at 10-second intervals)

Inter-instrument agreement

Δ E*ab within 0.8
(Measurement conditions : Comparison of average measured values of 13 BCRA Series || color tiles to values measured with master body)

Temperature range

Operation: 0° to 40°C (32° to 104°F); Storage: -20 to 40°C(-4 to 104°F)

Humidity range

Less than 85% relative humidity at 35°C/95°F with no condensation

Dimensions

229 x 91 x 60mm
(9 x 3-9/16 x 2-3/8 in.)
Connecting cable: 1300 x 8.5mm  (51-3/16 x 5/18 in.)

Weight

690g(24-3/8oz.)

Accessories Included

Calibration Plate CR-A44;
Case Cr-A64

DP-301 Specifications

Measurement modes

Absolute and difference

Chromatic systems

absolute: CIE Yxy, L*a*b*, L*C*h,
and XYZ; Hunter Lab  Difference:
Δ (Yxy), Δ(L*a*b*)/ ΔE*ab, Δ(L*C*h*)/Δ E*ab,
and Hunter Δ(Lab)/Δ E

Illuminant conditions

CIE Illuminant C or D65

Calibration channels

20; calibration channel 00 for primary standard(white calibration plate), channels 01 to19 for user-selected reference colors

Calibration functions

Multi-calibration: data in all calibration channels utilized to determine measured values
Manual: Data in a single calibration channel selected by user utilized to determine measured values

Target-color channels

20; set by measurement or keyboard input

Data memory

Space for 300 sets of measurement  data; space divisible into 20 pages;
data remains in memory even if POWER switch is set to OFF

Display range

0.01 to 160% reflectance

Display

16 characters x 2 lines ;
dot-matrix LCD with adjustable
viewing angle

Printer

24-character thermal-dot

Statistical calculations

Maximum, minimum, mean, and standard deviation

Calendar/clock/timer

Data and time of first and last measurements on each memory page stored and printed out; timer intervals user-selectable from 3 sec. to 99 min.

Data input/output

RS-232C format, ASCII code; transmission rate: 4800 baud (selctable by service personnel: from 600 to 9600 baud for data output or from 600 to 4800 baud for data input); output voltage: CMOS 5V; RS-232C terminal uses DIN 8-pin connector

Other

High-repeatability multiple-measurement-averaging mode; remote-control socket; E ALARM output socket

Power source

6 AA-size alkaline-manganese or carbon-zinc (1.5V) or nickel-cadmium (1.2V) batteries, or included AC adapter connected to AC power source; memory equipped with built-in Ni-Cd battery

Battery performance

Alkaline-manganese: 690 measurements; Carbon-zinc: 280 measurements; Nickel-cadmium: 600 measurements(Measurement conditions: Primary standard measured in ABS. measuring mode at 10-second intervals with printout in one color space after each measurement)

Temperature range

Operation: 0 to 40°C (32 to 104°F)
Storage: -20 to 40°C(-4 to 104°F)

Humidity range

Less than 85% relative humidity at 35°C/95°F with no condensation

Dimensions

50 x 220 x 200mm
(2 x 8 11/16 x 7 7/8 in.)

Weight

1300g (45 7/8 oz.) without batteries

Accessories Included

AC Adapter (AC-A10 worldwide except N. America;
AC-A10N in N. America);
thermal paper (one roll);
DIN 8-pin plug (1); 3.5mm(1/8 in.) subminiature plug(2)