Millipore Milli-Q Integral 3
| Objektnummer | B00024562 |
|---|---|
| Seriennummer | 024562 |
| Nome oggetto | Millipore Milli-Q Integral 3 |
| Stato | Archived Product |
Gruppo prodotti: Trattamenti per Acqua
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Hersteller: Millipore
Modell: Milli-Q Integral 3
Die folgenden Abbildungen und Beschreibungen beziehen sich auf das Gerätemodell und stammen aus Prospekten. Sie stellen nicht den Lieferumfang dar. Den genauen Lieferumfang entnehmen Sie bitte dem Angebotstext.
Technische Daten
Milli-Q ® Wasserqualität
Spezifischer Widerstand 18,2 MΩcm bei 25 ° C
TOC <5 ppb
Partikel> 0,22 μm ** <1 Partikel / ml
Bakterien ** <1 KBE / ml
Pyrogene * <0,001 Eu / ml
RNasen * <0,01 ng / ml
DNasen * <4 pg / µL
Durchflussrate ** 0,05 - 2 l / min
(*) Mit BioPak-Endfilter
(**) Mit Millipak- oder BioPak-Endfilter
Gewicht
Artikel Betriebsgewicht Trockengewicht Versandgewicht
-------------------------------------------------- -------------------------------------------------- --------------
Q-POD-Einheit 4,7 kg 4,6 kg 7,2 kg
Milli-Q Integral 3 Schrank 24 kg 18 kg 22 kg
Milli-Q Integral 5 Schrank 25 kg 19 kg 23 kg
Milli-Q Integral 10 Schrank 27 kg 20 kg 24 kg
Milli-Q Integral 15 Schrank 8 kg 21 kg 25 kg
Elektrisch
Spannung 100-230 VAC ± 10%
Frequenz 50-60 Hz ± 10%
Hauptsicherung 2,5 A flink; 5 mm x 20 mm; 250 V
Sicherheitsspannung Die Sicherung sollte von einem Fachmann gewartet werden
Leistungsaufnahme 160 VA
Länge des Netzkabels 2,5 Meter
Elektrische Erdung Geerdet
Verwendung des Netzkabels Das Milli-Q-System wird ein- und ausgeschaltet, indem das Netzkabel aus der Steckdose gezogen wird.
Das Netzkabel sollte an eine Wand angeschlossen werden
Speisewasser
Art des Speisewassers Trinkwasser
Leitfähigkeit <2000 µS / cm
Druck 1 bar <P <6 bar
Temperatur 5 ° C <T <35 ° C
Gelöstes CO2 <30 ppm
Freies Chlor <3 ppm
Verschmutzungsindex <12
pH 4 <pH <10
Maximaler TOC <2000 ppb
Eisen <0,1 ppm
Mangan <0,05 ppm
Aluminium <0,05 ppm
Umwelt
Höhe <3000 Meter
Betriebsumgebungstemperatur 4 - 40 ° C
Lagertemperatur 4 - 40 ° C
Installationskategorie II
Standort Das Milli-Q-System ist vorgesehen für
nur Innen benutzen.
Verschmutzungsgrad 2
Relative Luftfeuchtigkeit während der Lagerung Maximale relative Luftfeuchtigkeit 80%
und Betrieb bei Temperaturen bis 31 ° C
linear abnehmend auf 50% relativ
Luftfeuchtigkeit bei 40 ° C.
Geräuschpegel
Der Geräuschpegel beträgt <50 dB in einem Abstand von 1 Meter.
Verbrauchsmaterial
Die für die Installation erforderlichen Mindestverbrauchsmaterialien sind hier aufgeführt.
Beachten Sie, dass diese Artikel nicht im Lieferumfang des Milli-Q-Systems enthalten sind und separat bestellt werden müssen:
- Progard Pack,
- Quantum Cartridge und
- POD Pak.
Reservoir Lage
Das Reservoir muss sich in Bezug auf das Milli-Q-Gehäuse befinden:
0 ≤ y ≤ 2 Meter, wobei y = vertikaler Abstand ist, und
0 ≤ x ≤ 3 Meter, wobei x = horizontaler Abstand.