Archivio

Micromeritics ASAP 2000

Seriennummer: 017504
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
Micromeritics Particle size analyzer ASAP 2000. Interface. Software ASAP 2010 V.4.00 and DFT V.1.03 for control and analyse. With 3 rehearsing glasses. Without vacuum pump
siehe Storeview
Maggiori Informazioni
Objektnummer B00017504
Seriennummer 017504
Nome oggetto Micromeritics ASAP 2000
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Micromeritics

model :                   ASAP 2000

annotation :           Dokumente engl.

 

 

Attention: This is description for ASAP 2010. The Models are identical.

 

The ASAP 2010 System consists of an analyzer, a control module, which en­able you to enter analysis and report options, and an interface controller, which controls analyses.

 

 

The ASAP 2010 analyzer contains two sample preparation ports and one analysis port. In-line cold traps are located between the vacuum pump and the manifold in both the analysis and the degas system. The sample saturation pressure ( Psat ) tube is located next to the sample analysis port.

The analysis bath fluid Dewar resides on an automatically-operated elevator. Controls and indicators located on a control panel operate the vacuum sys­tems, degas valves, and heating mantles. A sliding shield can be lowered to provide safety or raised to provide access to the sample analysis port and preparation ports.

 

Gas Requirements

Compressed gases are required for analyses performed by the ASAP 2010 analyzer. Gas bottles or an outIet from a central source should be located near the analyzer.

Appropriate regulators which have been leak checked and specially cleaned are required. Pressure relief valves should be set to no more than 30 psig (200 kPag). Gas regulators are available from Micromeritics; refer to Chap­ter 10, Ordering Information.

 

 

Specifications

PRESSURE MEASUREMENT        

Range:                               0 to 950 mmHg

Resolution:

1000 mmHg Range           0.052 mmHg

10 mmHg Range*              0.0005 mmHg

1 mmHg Range*                0.00005 mmHg

Accuracy: (Includes non-linearity hysteresis and non-repeatability.
Transducer manufacturer's specifications.)

1000 nnring Range            Within 0.1% of full scale

10 mmHg Range*              Within 0.15% of reading

1 mmHg Range*                Within 0.15% of reading

1 mmHg Range* 1              Within 0.12% of reading (for long term

stability )

 

MANIFOLD TEMPERATURE TRANSDUCER      

Type:                                  Solid-state absolute temperature device

Accuracy:                           ± 0.02°C (by keyboard entry)

Stability:                              Within ± 0.1°C per month

(Transducer manufacturer's

specifications .)

 

VACUUM SYSTEM   

Vacuum Pumps:                Two independent, 2-stage mechanical

pumps ; one for analysis and .one for degas. Ultimate vacuum 5 x 10 -3 mmHg.

Molecular Drag Pump*:     Ultimate vacuum 1 x 10 -5 mrnRg (Analysis System)

 

*Krypton and micropore systems

1 Optional, high-stability, 1-mmHg .transducer

 

DEGAS SYSTEM      

Temperature Range :         Ambient to 350°C with glass fiber heating

                                          mantles (450°C with optional quartz fiber heating mantles)

Selection:                           Digitally set, 1°C incrernents

Accuracy:                           Deviation less than ±10°C of set point at thermocouple

Backfill Gas:                       User-selectable, typically helium or nitrogen

 

SYSTEM CAPACITY       

Sample Preparation:          2 degas ports

Analysis:                             1 sample port and 1 saturation pressure tube

Total Operating Capacity: Up to four complete analysis units can be independently controlled by one control module

 

LIQUID NITROGEN SYSTEM

Special Features:               Patented Isothermal Jackets effectively maintain LN 2 level constant an sample tube and Po tube during analysis while evaporation of LN 2 occurs

Capacity                             1.9 Liter Dewar, which provides up to 60 hours of unattended analysis

Analysis Time:                   Unlimited. LN2 Dewars may be refilled without affecting the accuracy of results

 

SAMPLE SIZE

Sample tubes are available for various size pellets, cores and powders. Sam­ple tube Sterns are normally 1/2-inch OD with 9-cc bulbs. Also available

are 1/4- or 3/8-inch OD with 9-cc bulbs. Monolithic samples up to 12 mm diameter x 25 mm Jong fit into a taper-sealed tube. Special tubes can be de­signed to accommodate unusual samples.

 

ENVIRONMENT

Temperature:                     10 to 30°C operating; -10 to 55°C storing or shipping

Humidity:                            20 to 80% relative, non-condensing

 

ELECTRICAL

Voltage:                              100,115, 230 VAC ±10%

Frequency:                         50/60 Hz

Power:                                1100 VA, operating

 

GASES

Normal :                              Argon, carbon dioxide, nitrogen, krypton (Krypton System), and other suitable gasen

                                         

PHYSICAL

Height:                                91 cm (35.8 in.)

Width:                                 71.1 cm (28 in.)

Depth:                                49 cm (19.3 in.)

Weight:                               100 kg (220 lbs)

 

Gruppo prodotti: Analizzatori Granulometrici