Titolatori

Metrohm 877 Titrino plus

Special Price 8.241,75 €
-25%
Sconto
Regular Price 10.989,00 €
Excl. 19% VAT , excl. Shipping Cost
9.807,68 € incl. Vat
Seriennummer: 31188
Stato: Stock unit?The device is in our stock, however, has to be inspected by our technician, in order to be able to guarantee complete function.
Spedizione: 10-14 working daysiFor incoming orders until 12:00 (German local time). If customs handling is required, shipment will be delayed.
Descrizione:
Metrohm Titrino plus 877. Con
Agitatore ad elica. Supporto per titolazione con controller.
Ecotrode plus. Sostituire l'unità 806.
Sensore di temperatura Pt1000. Vari cavi.
Colonna anionica IC Metrosep A. Colonna cationica C4.
Autocampionatore IC più 919. Misuratore di pH / conducibilità a due canali.
Cella di misurazione della conducibilità.
Add to Offer list
Maggiori Informazioni
Objektnummer B00031188
Seriennummer 31188
Nome oggetto Metrohm 877 Titrino plus
Stato Lagergerät
Anno do costruzione 2015
Fabbricante Metrohm
Spedizione 10-14 working days

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

 

Manufacturer: Metrohm

Model:             877 Titrino plus

                           

 

The following illustrations and descriptions are model-related and taken from brochures.

They do not reflect the scope of delivery of the system.

The exact scope of delivery can be found in the offer text.

 

Technical specifications

 

Measuring inputs: The measuring cycle is 100ms for all measuring modes

potentiometry

Input resistance                             > 1 · 1012 Ω

Offset current                                 <1 · 10-12 A

Measuring mode pH                      Measuring range -13 ... + 20.

Resolution                                      0.001.

Measuring accuracy                      ± 0.003 (± 1 digit, without error of the sensor, under reference conditions)

Measuring mode U                        Measuring range -1200 ... + 1200 mV.

Resolution                                      0.1 mV. Measuring accuracy ± 0.2 mV (± 1 digit, without error of the sensor, under reference conditions)

Polarizer

Measuring mode Ipol                     Determination with selectable polarization current .

Polarization current                       -120 ... + 120 μA (increment: 1 μA)

                                                      -125 ... -121 μA / + 121 ... + 125 μA: non-guaranteed values, depending on reference voltage +2.5 V

Measuring range                           -1200 ... + 1200 mV

Resolution                                      0.1 mV

Measuring accuracy                       ± 0.2 mV (± 1 digit, without error of the sensor, under reference conditions)

Measurement mode Upol               Determination with selectable polarization voltage.

Polarization voltage                        -1200 ... + 1200 mV (increment: 10 mV)

                                                        -1250 ... -1210 mV / + 1210 ... + 1250 mV: non-guaranteed values, depending on reference voltage + 2.5V

temperature

Measuring range Pt1000                 -150 ... + 250 ° C

NTC                                                  -5 ... + 250 ° C (For a NTC sensor with R (25 ° C) = 30000 Ω and B (25/50) = 4100 K)

Resolution Pt1000                             0.1 ° C

NTC                                                   0.1 ° C

Measuring accuracy Pt1000              ± 0.2 ° C (Applies to measuring range -20 ... + 150 ° C)

NTC                                                   ± 0.6 ° C (Applies to measuring range + 10 ... + 40 ° C)

metering

Resolution                                          10,000 steps per cylinder volume

Exchange unit cylinder                        volume ■ 1 mL ■ 5 mL ■ 10 mL ■ 20 mL ■ 50 mL

Accuracy                                             Meets ISO / DIN standard 8655-3

interfaces

USB (OTG) connector                        Connects to USB devices.

MSB connection                                  For connecting a stirrer.

Remote connection                             For connecting devices with remote interface.

mains connection

Mains voltage                                      100 ... 240 V (± 10%)

Frequency                                            50 ... 60 Hz

Power consumption                             45 W

Fuse                                                     2 × 2.0 ATH, electronic overload protection

ambient temperature

Nominal functional range                     + 5 ... + 45 ° C (with max. 85% humidity)

Storage                                                -20 ... + 60 ° C

Transport                                             -40 ... + 60 ° C

 

 

 

 

 

 

 

 

 

 

 

 

Gruppo prodotti: TITR

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure