Merck-Hitachi F-1050
| Objektnummer | B00007397 |
|---|---|
| Seriennummer | 007397 |
| Nome oggetto | Merck-Hitachi F-1050 |
| Stato | Archived Product |
Gruppo prodotti: HPLC-Detectors
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Principle of operation

The radiation coming from the mercury-xenon lamp is converged and enters the excitation monochromator, in which it is dispersed by the large-aperture concave grating, and only the light beam of a specific wavelength band is allowed to pass through the exit slit. The light beam passing through the excitation monochromator irradiates the Sample through the condenser lens. Thus, fluorescence is emitted from the Sample. The fluorescing radiation from the sample enters the emission monochromator, in which it is dispersed by the concave grating, and the selected light beam is given to the measuring photomultiplier detector.
On the other hand, the excitation light beam transmitted through the sample reaches the monitor detector through the condenser lens, attenuator and diffusion plate. The voltage applied to the measuring photomultiplier is controlled using the output of this monitor detector. Therefore, even if the intensity of radiation from the light source fluctuates, correction is made by changing the gain of measuring photomultiplier.
Product Specifications
Excitation Monochromator
Large-aperture stigmatic concave grating, 1000 lines/mm F : 3
Emission Monochromator
Large-aperture stigmatic concave grating, 1000 lines/mm F : 2.8
Wavelength Range
Excitation fluorescence spectrum 220 to 650 nm, and zero order
Emission fluorescence spectrum 220 to 730 nm, and zero order
Bandwidth
15 nm, fixed
Wavelength Accuracy
±7 nm
Light Source
150 W mercury-xenon lamp
With ozone self-dissociation function, and thermo-sensor function for detecting excessive temperature
Lamp Power Source
Built in the instrument
High frequency switching method
Detectors
For measurement ... R372F (photomultiplier tube)
For monitoring .... R1413 (photomultiplier tube)
SENSITIVITY Selection
0.01, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 100 (11 steps selectable)
Time Constant
0.3, 1, 3 sec (3 steps selectable)
Zero Adjustment
Zero adjustment available with background compensation
|
Flow Cell Capacity |
Flow Path |
Exposure to Light Beam |
Pressure Resistance |
|
|
12 µl |
1.3 mm X 1.3 mm X 12 mm |
1.3 mm X 1.3 mm X 7 mm = 12 µl |
30 kgf/cm 2 (2.9 MPa) |
|
|
2 µl |
0.3 mm X 1.0 mm X 12 mm |
0.3 mm X 1.0 mm X 7 mm = 2 µl |
30 kgf/cm 2 (2.9 MPa) |
|
|
40 µl |
2.4 mm X 2.4 mm X 12 mm |
2.4 mm X 2.4 mm X 7 mm = 40 µl |
30 kgf/cm 2 (2.9 MPa) |
|
Sensitivity
|
Cell |
Sensitivity |
|
12 µl flow cell |
Raman spectrum of water measurable at S/N ratio of more than 110 |
|
2 µl flow cell |
Raman spectrum of water measurable at S/N ratio of more than 30 |
|
40 µl flow cell |
Raman spectrum of water measurable at S/N ratio of more than 120 |
|
10 mm cell |
Raman spectrum of water measurable at S/N ratio of more than 120 |
Excitation wavelength ... 350 to 370 nm
Time constant ........... 1 sec
Dimensions
260 (W) X 500 (D) X 200 (H) mm
Weight
18 kg
Power Consumption
350 W
Allowable Voltage Variation Within ±10 % of rated level
Power Supply Frequency
50/60 Hz
Output Voltage
(a) Output to recorder ......... 10 mV
(b) Output to data processor ... 1 V