Archivio

Merck-Hitachi D-7500

Seriennummer: 012722
Stato: Archived Product?The unit is no longer available.
Spedizione:
Descrizione:
siehe Storeview
Maggiori Informazioni
Objektnummer B00012722
Seriennummer 012722
Nome oggetto Merck-Hitachi D-7500
Stato Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Merck-Hitachi

Modell:            D-7500

Kommentar:    Dokumente engl.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Specifications

Power Supply and External Dimensiions

a. Power supply and consumption        100 - 240 V AC

b. Operating temperature                      10 - 35 °C

c. Humidity                                             R.H. 45 - 85 %

d. External dimensions                          Width: 405 mm

                                                              Depth: 445 mm

                                                              Height: 160 mm

e. Weight                                               About 8 kg

Input

a. Input signal                                        Digital input: 2

                                                              Analog input: 1 (2 at Option)

b. Number of simultaneous

processing channels                             2

c. Integration range                                1 ~ 10 9 µV • sec

d. Pulse height range                            1 ~ 10 6 µV

e. Linearity                                             ± 0.1 %

f. Sampling period                                 50, 100, 200, 400, 800, 1600, 3200, ms

Analog input

a Input voltage                                       -10 mV ~ 1 V

b Input impedance                                 10 MΩ

Storage

a. Storage time                                        About 20 hours at sampling period 800 ms

                                                                About 3.5 hours at sampling period 400 ms

b. Number of storable chromatograms   About 40

                                                                30-minute chromatograms at sampling period

                                                                800 ms

c. Number of peaks for concentration

    calculation                                            About 24,000

d. Marker signal input time                       300 max. (marker can be superimposed on chro­            matogram for 1 channel only)

Waveform Processing

a. Method of waveform processing         Automatic or parameter setting

b. Peak processing on tailing                  Automatic or parameter setting

c. Peak processing on leading                Parameter setting

Identification of Peak

• Absolute or relative retention time method

1 Identification windth                              Percentage or absolute time method

2 Number of identifiable peaks                Up to 250

Calculation

a. Quantitative calculation                       1. Simple percentage method

                                                                2. Peracent normalization method

                                                                3. Intemal standard method

                                                                4. Absolute calibration curve method (external    standard method)

                                                                5. Exponential calculation

b. Other calculations                               1. Grouping            

                                                                2. Multi-data            → Up to 30 peaks

                                                                3. Multi-file              

                                                                4. Averaging

                                                                5. Background subtract

                                                                6. Slice d ata

                                                                7. Data diagnosis

                                                                8. Relative standard deviation (Up to 5 data)

c. Calibration                                            1. Average of several standard measurements

                                                                2. 1 to 8-level calibration curve (graph display possi‑

ble)

3. Automatic correction of retention time

4. Cancellation of unsatisfactory analysis

Recording

a. Recording system                               Ink jet printer/plotter

b. Recording chart                                   Z-fold chart

                                                                • Width 239 mm, length 279 mm/page (11 inch)

                                                                • Width 239 mm, length 305 mm/page (12 inch)

                                                                • Width 239 mm, length 297 mm/page (A4)

c. Chart speed                                         Up to 60 mm/min (1.25, 2.5, 5, 10, 20, 40, 60     mm/min)

d. Pen speed                                           60 characters/sec

e. Number of retention time digits           5 (600.00 min) or 6 (600.000 min) selectable

f. Number of peak area digits                  9 (999,999,999 µV •s)

g. Number of peak height digitis              6 (999,999 µV)

h. Number of concentration digits           7 (8000.000%)

i. Chromatogram recording                     Unrestricted

j. Chart rewinding                                     up to 500 mm

Time Program                                        • Controllable according to time designation

                                                                • 25 steps programmable in combination of 16   functions

                                                                1. INTEG INHIB

                                                                2. PLOT ATT

                                                                3. PLOT ON/OFF

                                                                4. CHART SPEED

                                                                5. MANUAL

                                                                6. SENS

                                                                7. VERT

                                                                8. TAIL

                                                                9. LEAD

                                                                10. N-METH

                                                                11. F-HORIZ

                                                                12. B-HORIZ

                                                                13. NEG-PK

                                                                14. AUTO-Z

                                                                15. GROUP

                                                                16. OFFSET

Various Tables

a. Component table                                 16 tables can be generated

b. Link table                                              Up to 9 links (1~9) possible           Backed up by battery

c. Comment table                                    Contains 5 lines of 30 characters each

d. Sample table                                        Contains up to 200 samples

Number of Files                                     9 storage files

                                                                2 standard files (for GC and LC)

Chromatogram Overlay                        Up to 5 chromatograms

                                                                (but calculation result is not printed, and only      rerecording possible)

Communication

a. RS-232C

Connection terminal                          RDED-9PE

Sync system                                      Asynchronous serial transfer

Communication system                    Full duplex (bidirectional communication possible)

Input/output level                                 RS-232C input/output

Communication bit format                  8 data bits + 2 stop bits

                                                                7 data bits + 1 even parity bit + 2 stop bits

Baund rate                                          2400, 1200, 600, 300, 150, 75 bps, selectable by DIP    switch

b. D-line

Baud rate                                            19200 bps

Contacts                                             START, ERROR STOP, BUSY